Mantech

MT series automated titration systems

Configurable automated titration and multi-parameter analysis systems for environmental and laboratory testing
Automated sample handling for high-throughput analysis
Configurable systems for multiple analytical parameters
IntelliRinseâ„¢ technology for controlled probe rinsing

MT series automated titration systems

The MANTECH MT series combines automated titration, electrode measurements and multi-parameter analysis in configurable laboratory systems. Designed for environmental and industrial testing, these analyzers support the determination of pH, alkalinity, acidity, conductivity, chloride, hardness and other analytical parameters.

Each system uses a modular configuration to match laboratory requirements for sample volume, analytical methods and throughput. The series includes benchtop instruments and automated systems for higher sample capacities.

Automated titration and multi-parameter analysis

The MT series supports several analytical techniques, including potentiometric titration, ion-selective electrode measurements and direct probe analysis.

Potentiometric titration determines parameters such as alkalinity, acidity, chloride and total hardness. Other configurations support measurements of pH, conductivity, fluoride, ammonia, turbidity and additional parameters.

Depending on the model and configuration, laboratories can combine multiple analytical methods within one system. The MT100 supports analysis of multiple parameters from a single sample cup, reducing the need for separate sample vessels.

Automated sample handling and probe rinsing

The MT10, MT30 and MT100 provide automated sample handling for laboratories processing larger sample batches. The MT100 supports configurations with capacities of up to 720 samples per batch.

MANTECH’s IntelliRinseâ„¢ technology uses controlled probe rinsing between measurements to reduce the risk of sample carryover. Available rinsing functions vary by model.

The MT100 also supports automated sample pipetting with TitraSipâ„¢ technology. This allows laboratories to automate liquid handling and titration steps while reducing manual intervention.

MANTECH Proâ„¢ software

All MT series models use MANTECH Proâ„¢ software to manage analytical workflows, measurements and results.

The software provides a customizable interface with automated quality control checks and calibration functions. Users can monitor results in real time, manage sample priorities and access historical analytical data.

LIMS data transfer supports the integration of analytical results into laboratory information management workflows.

Configurable systems for different laboratory requirements

The MT series includes several models for different levels of automation.

The MT3 and MT5 offer benchtop analysis with manual probe placement. The MT10 and MT30 introduce automated sample handling, while the MT100 supports more advanced liquid handling and multi-parameter workflows.

Available configurations include different sample cup sizes, probe arrangements and analytical methods.

Applications in environmental and industrial laboratories

The MT series supports routine testing and quality control across several laboratory applications:

  • Water and wastewater analysis: pH, conductivity, alkalinity, hardness, chloride and other water quality parameters.
  • Environmental testing: analysis of selected chemical parameters in environmental samples.
  • Soil and agricultural testing: selected nutrient and chemical measurements using suitable sample preparation and methods.
  • Food and beverage testing: selected quality control parameters and water-related measurements.
  • Industrial laboratory analysis: routine titration and multi-parameter testing of compatible samples.

The appropriate model, probes and analytical methods depend on the sample matrix and required parameters.

Key features

  • Modular system design: configurable analytical modules for different parameters, sample volumes and throughput requirements
  • Automated sample handling: autosampler configurations for the MT10, MT30 and MT100
  • Multi-parameter analysis: supports combinations of titration, electrode measurements and other analytical methods
  • IntelliRinseâ„¢ technology: controlled probe rinsing to reduce sample carryover
  • MANTECH Proâ„¢ software: centralized control with calibration, quality control and result management
  • LIMS integration: transfer of analytical results to laboratory information management systems
  • SampleProtectâ„¢: available on MT10, MT30 and MT100 systems
  • Automated temperature compensation: Integrated thermistor functionality on MT30 and MT100 systems
  • TitraSipâ„¢ Gen2: Automated pipetting and liquid handling for MT100 configurations
  • RapidDuoâ„¢: MT100 configuration for coordinated pipetting and titration workflows

Specifications

 

Specification MT3 MT5 MT10 MT30 MT100
Sample handling Manual Manual Automated Automated Automated
Batch capacity Manual probe dip Manual probe dip 32–560 samples 32–560 samples 32–720 samples
MANTECH Proâ„¢ software Yes Yes Yes Yes Yes
DualProbe — — Yes Yes Yes
IntelliRinse™ — — Static/dip Dynamic Dynamic
SampleProtect™ — — Yes Yes Yes
Sample cup sizes 125 mL 125 mL 50, 125 mL 50, 125 mL 15, 50, 125 mL
Autom — — — — Yes
Multiple methods Different cups Different cups Different cups Different cups Single cup

Available analytical parameters

Acidity, alkalinity, ammonia, chloride, color, conductivity, fluoride, nitrate, oxidation-reduction potential (ORP), dissolved oxygen, pH, salinity, temperature, total hardness and turbidity.

Parameter availability depends on the model, analytical method and selected configuration.

Ask about this instrument

SciSPX helps laboratories in Belgium, the Netherlands and Luxembourg find the right analytical instruments, with expert advice, installation, training and technical support.

Frequently asked questions

The MT series supports automated titration and multi-parameter analysis in environmental and industrial laboratories. Applications include water quality testing, wastewater analysis and routine chemical measurements.

Depending on the configuration, the systems can measure pH, conductivity, alkalinity, acidity, chloride, hardness, ammonia, fluoride, turbidity and other parameters.

The MT100 supports automated configurations with capacities ranging from 32 to 720 samples per batch. Actual capacity depends on the sample vessels and autosampler configuration.

Yes. The MT100 supports multi-parameter workflows from a single sample cup. Other models can perform multiple methods using separate sample cups.

IntelliRinseâ„¢ uses controlled rinsing and measurement feedback to improve probe cleaning between samples. This helps reduce the risk of carryover and cross-contamination.

Downloads

Brochure MT Series

Related instruments

Turbidity meter

T10 Turbidity Meter

Rapid, accurate, and reliable turbidity analysis
COD analyzer

PeCOD COD analyzer

Fast, green, and accurate Chemical Oxygen Demand analysis
BOD analyzer

PC-BOD analyzer

Biochemical Oxygen Demand Analysis System

Last viewed products

No products found

Contact our Xperts

Prefer to give us a call?

The Netherlands
+31 (0)294 280 450

Belgium & Luxembourg
+32 (02)2 334 22 70