Elementar

Iso FLOW

Isotope analysis of gases, liquids, and carbonate minerals in one system
Up to 180 heated samples (liquids or carbonates)
Up to 220 non-heated samples (gases)
Multi-core needle for automated preparation and sampling

Iso FLOW

Isotope analysis of gases, liquids, and carbonate minerals

What is iso FLOW? 

Iso FLOW is a fully automated, continuous flow preparation system for isotope ratio mass spectrometry (IRMS). It is ideal for the isotopic analysis of samples prepared in septum-sealed vials, including gases, liquids, and carbonate materials.

The system supports a wide range of applications such as geoscience, climate research, food authenticity, hydrology, and clinical studies. Its flexibility and automation make it a versatile solution for IRMS laboratories working with diverse sample types.

Why use iso FLOW for isotope analysis?

Iso FLOW offers specific advantages for liquid and carbonate isotope analysis in comparison to other preparation techniques.

For water isotope analysis (δ²H and δ¹⁸O), it uses an equilibration technique that avoids interference from dissolved or particulate organic matter. This eliminates the need for sample pre-treatment such as filtration or distillation, even for complex matrices like:

  • Fruit juices
  • Wines
  • Urine
  • River and estuarine waters

For carbonate analysis, iso FLOW enables accurate measurement of impure carbonate samples (e.g. apatite carbonates). Unlike dual inlet methods, it removes interferences caused by hydroxyapatite using its integrated UltiTrap GC separation system.

Flexibility 

The system is ideal to handle multiple sample types and analytical methods within a single platform.

Key flexibility features:

  • Analysis of gases, liquids, and carbonates in one system
  • Configurable operation for single or multiple analysis modes
  • Compatibility with different sample vial formats
  • Operator-defined sampling methods (single or multiple loop fills)

This allows laboratories to tailor the system to their specific analytical workflows.

How does UltiTrap improve analytical performance?

At the core of iso FLOW is the UltiTrap GC separation device, based on Advanced Purge and Trap (APT) technology.

UltiTrap can operate in different modes:

  • Isothermal mode: up to 200 °C for fast analysis of simple samples
  • Dynamic mode: sub-ambient temperatures using thermoelectric cooling and rapid heating

This enables:

  • Improved focusing and separation of gases
  • Better limits of quantification for small samples
  • Operation without cryogenics

Automation 

Iso FLOW provides full control of analytical parameters through the lyticOS® Software Suite.

This includes:

  • Control of flow rates and valves
  • Digital mass flow controllers for stable gas handling
  • Method-based variation of gas flows
  • Automated sleep and wake-up modes to conserve resources

The system enables fully automated sample preparation and analysis, reducing manual intervention and improving reproducibility.

High sample throughput 

Iso FLOW is ideal for high-throughput laboratories with large sample volumes.

Capacity per sequence:

  • Up to 180 heated samples (liquids or carbonates)
  • Up to 220 non-heated samples (gases)

Additional features supporting throughput:

  • Automated sample preparation and gas aliquoting
  • Integrated data processing via lyticOS®
  • Temperature-controlled sample tray up to 90 °C (±0.1 °C)

Unique needle design 

The system uses a multi-core, micro-volume needle for automated sample handling.

This single needle is used to:

  • Flush sample vials
  • Deliver reagents
  • Extract prepared sample gas

This design:

  • Simplifies instrument setup
  • Reduces maintenance
  • Increases flexibility across different analysis types

How are gas samples analyzed?

Gas samples require no pre-treatment and can be analyzed directly.

Key characteristics:

  • Analysis time of less than 4 minutes per sample
  • Standard use of 12 ml vials (other formats possible)
  • Configurable sampling (single or multiple loop fills)

Typical applications include:

  • Breath analysis (δ¹³C)
  • Atmospheric gases
  • Pure gas samples

How does liquid isotope analysis work?

For water isotope analysis, iso FLOW uses an equilibration technique.

Process:

  • Sample vial headspace is flushed with equilibration gas
  • Isotopic exchange occurs between liquid and gas phase
  • Equilibration time:
    • ~4 hours for δ¹⁸O
    • ~90 minutes for δ²H (with platinum catalyst)
  • The equilibrated gas is then analyzed by IRMS

The system uses a single equilibration gas, reducing gas consumption and simplifying operation.

How are carbonate samples analyzed?

Carbonate analysis is based on acid digestion.

Process:

  • Phosphoric acid is injected into the sample vial
  • CO₂ is generated through reaction with carbonate
  • Gas is transferred to IRMS for isotope analysis

Key advantages:

  • Direct-drive acid pump for precise and rapid dosing
  • Analysis of up to 180 samples per sequence
  • Suitable for samples down to 100 µg

Analytical configurations

You can configure Iso FLOW for different analysis modes:

Analysis mode Sample type Capacity per sequence Key conditions
Gas mode Gases Up to 220 samples < 4 min per sample
Liquid mode Waters, liquids Up to 180 samples Heated tray (~40 °C)
Carbonate mode Carbonate minerals Up to 180 samples Temperature range 30–90 °C

This allows flexible configuration depending on laboratory needs.

Sample types 

Iso FLOW supports a broad range of sample matrices:

  • Breath samples
  • Atmospheric and pure gases
  • Groundwater and precipitation
  • Seawater, river water, estuarine water
  • Ice cores
  • Fruit juices and purées
  • Wines, vinegars, and spirits
  • Biological fluids
  • Pure and biogenic carbonates
  • Soil and apatite carbonates
  • Dissolved inorganic carbonates (DIC)

Key features

  • High precision isotope analysis for liquids and carbonates
  • UltiTrap GC separation without cryogenics
  • Fully automated control via lyticOS
  • Operation in isothermal or dynamic GC modes
  • High sample capacity (up to 220 samples)
  • Multi-core needle for automated preparation and sampling
  • Modular system design for flexible configuration

Ask about this instrument

SciSPX helps laboratories in Belgium, the Netherlands and Luxembourg find the right analytical instruments, with expert advice, installation, training and technical support.

Frequently asked questions

Iso FLOW supports isotope analysis of gases, liquids, and carbonate minerals within a single system. This includes water samples, biological fluids, pure and atmospheric gases, and carbonate materials such as marine and soil carbonates.

Iso FLOW is widely used in geoscience, climate research, hydrology, food authenticity testing, clinical research, and environmental studies. Its automation and flexibility make it well suited for laboratories analyzing diverse sample matrices.

Iso FLOW uses a gas–liquid equilibration technique for water isotope analysis of δ²H and δ¹⁸O. This approach avoids interference from dissolved or particulate organic matter and eliminates the need for filtration or distillation, even for complex samples such as fruit juices, wines, urine, and natural waters.

For carbonate analysis, iso FLOW enables accurate isotope measurements of impure carbonate materials such as apatite carbonates. Integrated UltiTrap GC separation removes interferences caused by hydroxyapatite, which commonly affect dual‑inlet carbonate methods.

Iso FLOW is flexible because it enables gas, liquid, and carbonate isotope analysis on the same platform and allows operator‑defined sampling strategies. Laboratories can configure the system for single or multiple analytical modes depending on workflow requirements.

The temperature‑controlled tray maintains sample temperatures up to 90 °C with high stability. This ensures reproducible equilibration and reaction conditions for liquid and carbonate isotope analysis.

Carbonate samples are analyzed by acid digestion. Phosphoric acid is injected directly into the vial, generating CO₂ that is transferred online to the IRMS for isotope ratio measurement.

Downloads

Brochure iso FLOW

Related instruments

Elemental analyzer for EA-IRMS

Vario ISOTOPE cube

Designed for simultaneous carbon, nitrogen, and sulfur (CNS) isotope ratio analysis in samples up to 1 g
elemental analyzer for isotope ratio mass spectrometry (

Vario ISOTOPE select

EA-IRMS designed for simultaneous carbon, nitrogen, and sulfur isotope ratio analysis
Mass spectrometer 

Isoprime precisION

Last viewed products

No products found

Contact our Xperts

Prefer to give us a call?

The Netherlands
+31 (0)294 280 450

Belgium & Luxembourg
+32 (02)2 334 22 70