What is the Vario ISOTOPE select?

The vario ISOTOPE select is an elemental analyzer designed for isotope ratio mass spectrometry (EA-IRMS) that delivers reliable results with high robustness. It is ideal for simultaneous carbon, nitrogen, and sulfur isotope ratio analysis in samples with weights of up to 300 mg.

By combining efficient gas preconcentration with precise peak separation, the system ensures high accuracy and precision. It also offers the option for δ²H determination in water and is optimized for long-term operation with minimal maintenance requirements.

The instrument is ideal for routine, high-throughput isotope analysis while maintaining analytical performance. Its robustness, automation, and low maintenance contribute to high system uptime and reliable day-to-day operation.

Key advantages include:

  • Reliable performance for simultaneous NCS isotope analysis
  • High automation with minimal operator intervention
  • Low maintenance design for continuous operation
  • Autosampler options for unattended, high-throughput workflows

How does the Vario ISOTOPE select ensures excellent peak separation?

The system uses patented Temperature Programmed Desorption (TPD) technology to achieve complete peak separation during analysis.

Unlike fixed heating approaches, TPD dynamically controls temperature to release gases only after the previous peak has returned to baseline. This ensures:

  • Full peak separation, even for extreme elemental ratios
  • Excellent peak shapes and high signal-to-noise ratios
  • Accurate detection of very low sulfur concentrations in high carbon matrices (e.g. tree rings)

This process is supported by:

  • Furnace temperatures up to 1,200 °C
  • Jet-injection of oxygen directly at the combustion point

Together, these features ensure high sensitivity and analytical accuracy.

How is low-level δ¹⁵N analysis achieved?

The vario ISOTOPE select uses a zero-blank sample introduction system, enabling reliable analysis of low-level δ¹⁵N.

In addition, oxygen is injected directly at the sample during combustion, ensuring complete combustion efficiency while minimizing oxygen consumption. This results in matrix-independent performance, even for difficult sample types.

With the integrated thermal conductivity detector (TCD), the system achieves an elemental detection limit of < 100 ppm.

Designed for ease of use and uptime

The instrument is ideal to minimize downtime and simplify maintenance.

Design features include:

  • Large ash finger and separate combustion and reduction tubes
  • Tool-free maintenance using clamp connections
  • Slide-out furnace for easy access and improved ergonomics

These features contribute to high system uptime and consistent operation.

High-throughput analysis with autosampler options

The vario ISOTOPE select supports automated, unattended operation with flexible autosampler configurations.

Available options:

  • 120 or 240 position autosampler for solids and liquids (capsules)
  • Reloadable during analysis for continuous operation
  • Optional 2 ml vial liquid autosampler (50 positions) with rinse and waste vial

This enables 24/7 operation and high sample throughput, even for microsamples.

Which isotopes can be analyzed?

The system is optimized for:

  • δ¹³C
  • δ¹⁵N
  • δ³⁴S
  • δ²H (optional)

Analytical performance

Weighing range From micro samples (20 µg) to semi‑macro samples (300 mg, e.g. soil)
Elemental concentration range (absolute) Carbon: up to 7 mg
Nitrogen: up to 10 mg
Sulfur: up to 2 mg
Precision (external, 1σ) Elemental (C, N, S): < 0.1 %
δ¹³C: 0.1 ‰
δ¹⁵N: 0.15 ‰
δ³⁴S: 0.2 ‰
δ²H (optional): 0.5 ‰
Analysis time Approx. 3–4 minutes per element
Optimization Automatically optimized based on sample type, configuration, and content

Key features

  • High-temperature combustion up to 1,200 °C (up to 1,800 °C at combustion point with tin foil)
  • Jet oxygen injection for complete combustion and low gas consumption
  • Patented TPD purge-and-trap chromatography for gas separation
  • Thermal Conductivity Detector (TCD)
  • Integrated autosampler options (80*, 120, 240 positions)
  • Windows-based lyticOS® Software Suite with LIMS integration
  • Auto sleep and wake-up for unattended operation
  • Required gases: helium and oxygen
  • Dimensions: 48 × 55 × 57 cm (W × D × H)

* optional configurations available

 

Ask about this instrument

SciSPX helps laboratories in Belgium, the Netherlands and Luxembourg find the right analytical instruments, with expert advice, installation, training and technical support.

Frequently asked questions

The instrument enables the simultaneous analysis of carbon, nitrogen, and sulfur isotope ratios, specifically δ¹³C, δ¹⁵N, and δ³⁴S. An optional configuration allows δ²H determination in water.
The system supports a very wide weighing range, from microsamples of approximately 20 micrograms up to semi‑macro samples of 300 milligrams, such as soils.
It combines high automation, short analysis times, autosampler options for unattended operation, and a low‑maintenance design, which together result in high system uptime and reliable day‑to‑day performance.
Excellent peak separation is achieved using patented Temperature Programmed Desorption technology, which dynamically controls the release of gases so that each compound elutes only after the previous peak has fully returned to baseline.
Yes, the system is designed for unattended operation, enabling continuous 24/7 analysis with features such as autosamplers and automatic sleep and wake‑up functions.
A typical analysis requires approximately three to four minutes per element, making the system suitable for high‑throughput workflows.
The system achieves external precisions better than 0.1 percent for elemental carbon, nitrogen, and sulfur, with isotope ratio precisions of approximately 0.1 per mille for δ¹³C, 0.15 per mille for δ¹⁵N, 0.2 per mille for δ³⁴S, and 0.5 per mille for δ²H when configured.

Downloads

Brochure Vario ISOTOPE select

Related instruments

EA-IRMS

Vario PYRO Cube

This elemental analyzer for isotope ratio analysis (EA-IRMS) perfectly adapts to your analytical demands
Elemental analyzer for EA-IRMS

Vario ISOTOPE cube

Designed for simultaneous carbon, nitrogen, and sulfur (CNS) isotope ratio analysis in samples up to 1 g
Mass spectrometer 

Isoprime precisION

Last viewed products

No products found

Contact our Xperts

Prefer to give us a call?

The Netherlands
+31 (0)294 280 450

Belgium & Luxembourg
+32 (02)2 334 22 70