Elementar

Rapid MAX N exceed PLUS

Designed for simple and efficient nitrogen and protein determination using the Dumas method
Handles weights up to 5 g or 5 ml
90-position autosampler
Analysis in just 5 minutes

Rapid MAX N exceed PLUS

Dumas nitrogen and protein analyzer

What is the rapid MAX N exceed PLUS? 

The rapid MAX N exceed PLUS is a high-performance nitrogen and protein analyzer. It is designed for maximum laboratory efficiency and high sample throughput in nitrogen and protein determination. Using the safe, simple, and eco-friendly Dumas combustion method, it delivers results in just five minutes per sample.

Ideal for unattended 24/7 operation, the analyzer handles sample weights up to 5 g or 5 ml and a wide variety of sample matrices. Optimized consumables and the option to use argon as an alternative carrier gas reduce cost per analysis.

What sample types can the RAPID MAX N exceed PLUS analyze?

The upright crucible design supports sample weights and volumes up to 5 g or 5 ml, enabling analysis across a broad range of matrices without method changes:

  • Liquids: milk, beer, soft drinks, juice, soy sauce
  • Semi-liquids: yogurt, mayonnaise
  • Solids: meat, cereals, flour
  • But also: plastics and polymers, soil, sediments and fertilizers, plant material, starch and alternative proteins, animal feed

It’s an ideal solution for:

  • Food and feed industries
  • Contract laboratories
  • Public food and feed monitoring
  • Universities

What makes this analyzer flexible? 

  • High sample capacity: handles weights up to 5 g or 5 ml with complete combustion even for challenging matrices
  • Optional autosampler and kits: supports high-throughput processing and prioritization of urgent samples

How does it achieve best-in-class throughput? 

  • Quick daily maintenance: simplified routines reduce downtime
  • Fewer calibration runs: less time spent on calibration increases real sample throughput
  • 90-position autosampler: reloadable at any time, enabling uninterrupted analysis
  • Fast analysis: nitrogen and protein determination completed in five minutes per sample run

How does the RAPID MAX N exceed PLUS deliver reliable results?

  • Matrix-independent calibration: ensures consistent precision and accuracy across different sample types
  • Complete combustion: controlled oxygen jet-injection and catalytic post-combustion guarantee full sample oxidation
  • Absolute accuracy: high precision and recovery down to the low ppm range, even for hard-to-digest samples

Compliance with international and national standards

The exceed PLUS series meets numerous international standards for food, feed, and fertilizer analysis, including:

  • ISO: 16634-1, 16634-2, 14891
  • ICC: 167
  • EBC: 3.3.2, 4.3.2, 8.9.2, 9.9.2
  • AOAC: 990.03, 992.15, 992.23, 993.13, 997.09

It also complies with national standards such as Lufa and DIN.

Key features

  • Maximum sample flexibility with upright crucible design and post-combustion technology
  • Nitrogen and protein determination in just five minutes per sample
  • 90-position autosampler for high-throughput analysis
  • Smart software workflows, tool-free maintenance, and status display
  • Matrix-independent calibration for long-term precision
  • Complete combustion via controlled oxygen jet-injection and catalytic post-combustion
  • Safe, eco-friendly Dumas combustion method
  • 10-year commercial guarantee on high-temperature furnace and TCD cell
  • Compliance with international and national standards (ISO, AOAC, ICC, EBC, Lufa, DIN)

Ask about this instrument

SciSPX helps laboratories in Belgium, the Netherlands and Luxembourg find the right analytical instruments, with expert advice, installation, training and technical support.

Frequently asked questions

It can handle up to 5 g or 5 ml of sample.
Yes, it is ideal for unattended 24/7 operation.
You can analyze:
  • Food and beverage
  • Cereals, starch, and alternative products
  • Beer, wort, and malt
  • Plant material
  • Meat products
  • Plastics and polymers
  • Animal feed
  • Soil, sediments, and fertilizers
  • Milk and dairy products
  • Food and feed industries
  • Contract laboratories
  • Public food and feed monitoring
  • Universities
 
It supports sample weights up to 5 g or 5 ml, includes optional autosampler and kits, and allows prioritization of urgent samples.

Downloads

Brochure rapid MAX N exceed PLUS

Related instruments

organic element analyzers

Vario MAX Cube

Carbon, nitrogen, and sulfur determination by high-temperature combustion in organic samples up to 5 g
Versatile CHNS elemental analyzer for precise carbon, hydrogen, nitrogen and sulfur determination in a wide range of samples.

Vario EL Cube

Versatile CHNS elemental analyzer for precise carbon, hydrogen, nitrogen and sulfur determination in a wide range of samples
Nitrogen and protein analyzer | Dumas nitrogen analyzer

Rapid N exceed PLUS

Compact Dumas nitrogen and protein analyzer for fast, reliable analysis with low operating costs

Last viewed products

No products found

Contact our Xperts

Prefer to give us a call?

The Netherlands
+31 (0)294 280 450

Belgium & Luxembourg
+32 (02)2 334 22 70