EA-IRMS for environmental and aquatic research applications
Direct δ¹³C analysis of TOC in liquid samples
High-temperature combustion
TOC and TNb isotope ratio analysis directly in liquid samples

Iso TOC cube

Elemental analyzer inlet for EA-IRMS

What is the iso TOC cube? 

The iso TOC cube is an elemental analyzer designed for isotope ratio mass spectrometry (EA-IRMS), enabling the quantitative and isotopic analysis of dissolved total organic carbon (TOC) and total bound nitrogen (TNb) in aqueous samples.

Stable isotope analysis of dissolved carbon and nitrogen plays a key role in understanding biogeochemical cycling in aquatic systems. As dissolved matter represents a major pathway in these cycles, accurate quantification and isotope ratio analysis are essential.

The iso TOC cube introduces a high-temperature combustion method for this purpose and is the only commercially available instrument capable of performing both TOC and TNb isotope ratio analysis directly in liquid samples.

How does it perform TOC isotope analysis?

The iso TOC cube uses high-temperature combustion instead of wet-chemical or UV oxidation methods. This approach ensures complete conversion of all compounds, including refractory substances such as humic acids and lignin.

As a result, the system provides:

  • Matrix-independent measurements
  • High precision and accuracy across diverse liquid types
  • Reliable performance for difficult-to-combust samples

It supports a wide range of sample matrices, including drinking water, wastewater, soil leachates, suspensions, brines, and marine samples.

How is direct δ¹⁵N analysis of TNb achieved?

The iso TOC cube is the only system capable of direct δ¹⁵N isotope analysis of total bound nitrogen in aqueous samples.

This is achieved through:

  • A dedicated Low Concentration Module (LCM)
  • An integrated membrane degasser to remove dissolved N₂
  • Cryogen-free thermoelectric cooling combined with Advanced Purge and Trap (APT) technology

These features enable TNb detection levels down to 25 ppm and ensure clean separation of nitrogen signals.

High throughput without sample preparation

The iso TOC cube performs direct analysis of liquid samples, eliminating the need for time-consuming pre-treatment steps such as freeze drying.

This approach ensures:

  • Direct determination of dissolved carbon and nitrogen
  • Complete quantitative conversion of all compounds
  • Faster workflows
  • Reduced manual handling
  • Unattended 24/7 operation

Designed for ease of use and uptime

The instrument is built for reliable long-term operation with minimal maintenance.

Key design features:

  • Integrated autosampler with 32 positions (optional 50 positions)
  • Reloadable during operation
  • Tool-free maintenance via clamp connections
  • Slide-out furnace for easy accessibility
  • SALTTRAP technology for high-salinity samples

These features contribute to high system uptime and simplified daily operation.

Which parameters and isotopes can be analyzed?

The iso TOC cube is optimized for:

  • δ¹³C
  • δ¹⁵N (optional)

For the analysis of:

  • Total Organic Carbon (TOC)
  • Total Inorganic Carbon (TIC)
  • Total Carbon (TC)
  • Total Bound Nitrogen (TNb)

Analytical capabilities and performance

The iso TOC cube supports a wide range of concentrations and sample types, from trace levels to high concentrations and from freshwater to highly saline matrices.

  • 100% carbon and nitrogen recovery independent of matrix
  • Simultaneous δ¹³C and δ¹⁵N analysis at low concentration levels
  • Typical detection levels down to:
    • ~1 mg/L for carbon
    • ~15 mg/L for nitrogen

It supports liquid injection volumes of up to 3 ml.

Which applications and sample types are supported?

The iso TOC cube is suitable for a wide range of laboratories and research environments:

  • Environmental laboratories
  • Academic research groups
  • Quality control laboratories
  • Contract laboratories

Typical sample types:

  • Drinking water
  • Seawater
  • Wastewater (influent and effluent)
  • Brines
  • Soil leachates

Analytical specifications 

Maximum sample volume Volume injections up to 3 ml for optimal detection
Element concentration range Dissolved carbon: 5 ppm to 60,000 ppm
Dissolved nitrogen*: 25 ppm to 60,000 ppm
Precision – elemental (external, 1σ) Carbon: < 2 % relative
Nitrogen*: < 2 % relative
Precision – isotope ratios (external, 1σ) δ¹³C: 0.1 ‰
δ¹⁵N*: 0.2 ‰
Analysis time ~ 5 min in C mode
~ 15–20 min in CN mode*
Note Analysis time depends on sample type, analysis mode, and configuration

* optionally available

Key features

  • Direct δ¹³C analysis of TOC in liquid samples
  • Direct δ¹⁵N analysis of TNb (unique on the market)
  • High sample throughput through direct injection
  • Low-maintenance design for high system uptime
  • Optional preconcentration for low TOC samples

This makes it particularly suitable for environmental and aquatic research applications.

Specifications

High‑temperature combustion Quantitative combustion at 950 °C (up to 1,200 °C maximum)
Up to 1,200 °C ensures complete digestion of all sample types
Detection CO₂‑specific high‑sensitivity infrared detector (stand‑alone and IRMS mode)
NO‑specific infrared detector (stand‑alone mode, optional)
Sample introduction Syringe injection with bubble elimination
Integrated liquid autosampler (32 or 50 positions)
Automatic acidification and sparging
Software and control lyticOS® Software Suite (Windows‑based)
LIMS integration
Automated sleep and wake‑up for unattended operation
Required gases Helium and oxygen
Dimensions Module 1: 48 × 63 × 82 cm (W × D × H)
Module 2 (optional): 27 × 62 × 53 cm (W × D × H)

Ask about this instrument

SciSPX helps laboratories in Belgium, the Netherlands and Luxembourg find the right analytical instruments, with expert advice, installation, training and technical support.

Frequently asked questions

The iso TOC cube is an elemental analyzer designed as an inlet for isotope ratio mass spectrometry. It enables quantitative and isotopic analysis of dissolved total organic carbon and total bound nitrogen directly in aqueous samples.

Stable isotope analysis of dissolved carbon and nitrogen is essential for understanding biogeochemical cycling in aquatic systems, as dissolved matter represents a major pathway in these cycles and requires accurate quantification and isotope ratio determination.
The iso TOC cube is the only commercially available system that can perform both TOC and TNb isotope ratio analysis directly in liquid samples without complex sample preparation.

The system performs direct analysis of liquid samples, eliminating the need for time‑consuming preparation steps such as freeze‑drying, which significantly simplifies workflows and reduces manual handling.
TOC isotope analysis is performed using high‑temperature combustion rather than wet‑chemical or UV oxidation methods, ensuring complete conversion of all organic compounds, including refractory materials such as humic acids and lignin.
High‑temperature combustion ensures matrix‑independent measurements, high precision and accuracy across a wide range of liquid types, and reliable performance even for samples that are difficult to combust.
Direct δ¹⁵N analysis of TNb is achieved using a dedicated low concentration module, an integrated membrane degasser to remove dissolved nitrogen gas, and cryogen‑free thermoelectric cooling combined with advanced purge‑and‑trap technology.

Downloads

Brochure Iso TOC cube

Related instruments

EA-IRMS

Vario PYRO Cube

This elemental analyzer for isotope ratio analysis (EA-IRMS) perfectly adapts to your analytical demands
Elemental analyzer for EA-IRMS

Vario ISOTOPE cube

Designed for simultaneous carbon, nitrogen, and sulfur (CNS) isotope ratio analysis in samples up to 1 g
Mass spectrometer 

Isoprime precisION

Last viewed products

No products found

Contact our Xperts

Prefer to give us a call?

The Netherlands
+31 (0)294 280 450

Belgium & Luxembourg
+32 (02)2 334 22 70