Edinburgh Analytical

FE30

High-sensitivity fluorescence spectrometer
Scan speeds up to 60,000 nm/min
Water Raman signal-to-noise ratio up to 20,000:1 RMS-BG
Excitation and emission wavelength range from 200 to 900 nm

FE30

Fluorescence spectrometer

The FE30 is a high-sensitivity fluorescence spectrometer designed for fluorescence measurements in research, routine analysis and laboratory applications. It combines a sensitive optical system with fast spectral scanning and a wavelength range extending up to 900 nm.

With a water Raman signal-to-noise ratio of up to 20,000:1 RMS-BG and scan speeds up to 60,000 nm/min, the FE30 can measure low fluorescence signals while also supporting rapid acquisition of excitation, emission and 3D fluorescence spectra.

High-sensitivity fluorescence measurements

The FE30 combines an efficient optical and electronic system with a high-intensity 150 W xenon lamp and PMT detector. This configuration provides the sensitivity needed to detect relatively weak fluorescence signals and samples at low concentrations.

Under the specified water Raman measurement conditions, the FE30 achieves a signal-to-noise ratio of 1,000:1 RMS-PK and 20,000:1 RMS-BG.

Excitation and emission bandwidths can be selected from 1, 2.5, 5, 10 and 20 nm, allowing measurement conditions to be adjusted according to the required sensitivity and spectral resolution.

Fluorescence measurements up to 900 nm

Both the excitation and emission wavelength ranges extend from 200 to 900 nm. This enables the FE30 to measure fluorescence across the UV and visible regions and into longer wavelengths.

The extended range is particularly useful for fluorophores that absorb or emit at longer wavelengths and expands the range of samples that can be investigated with a single instrument.

Flexible fluorescence measurement modes

The FE30 supports several measurement modes through the Spectracle software, allowing the instrument to be used for both routine fluorescence measurements and more advanced sample characterization.

Excitation and emission scans

Excitation and emission spectra can be recorded to investigate the fluorescence characteristics of a sample. Synchronous wavelength scanning is also available.

Time scan

Kinetic measurements can be used to monitor fluorescence changes over time, including applications such as enzyme activity and other reactions.

3D fluorescence scan

3D scanning provides an overview of a sample’s fluorescence characteristics across excitation and emission wavelengths. The resulting excitation-emission maps can support sample characterization, fingerprint analysis and advanced modelling.

With scan speeds up to 60,000 nm/min, the FE30 can acquire the data required for 3D spectra within a few minutes.

Quantitation

Calibration curves can be generated for quantitative fluorescence analysis, including first- and second-order calibration. It is possible to then use these to determine unknown sample concentrations from their fluorescence response.

Fluorescence anisotropy

With the appropriate polarizer accessory, the FE30 can perform fluorescence polarization and anisotropy measurements for applications in areas such as biochemistry and biophysics.

Instrument validation

Built-in validation functions help laboratories check the performance of the FE30. The software supports automated water Raman scans for signal-to-noise assessment as well as excitation and emission wavelength accuracy checks.

This provides a convenient way to monitor instrument performance as part of routine laboratory workflows.

Sample handling and accessories

The FE30 has a large sample chamber that can accommodate different sample holders and accessories. This allows measurements to extend beyond standard liquid fluorescence samples to temperature-controlled liquids, powders and thin films.

Available options include:

  • Standard cell holder for 10 mm fluorescence cuvettes
  • Thermostatic water bath cell holder for temperature-controlled measurements
  • Variable-angle solid sample holder for powders and thin films
  • Micro powder sample holder for small quantities of powder
  • Polarizer accessory for fluorescence anisotropy measurements
  • Laser source holder for coupling an external excitation laser

The variable-angle solid sample holder supports continuous 360° rotation and measurement angles from 0 to 90°, while the thermostatic water bath holder supports measurements at approximately 0 to 100°C.

Applications

The FE30 can be used for fluorescence measurements across a range of research and analytical fields, including:

  • Food analysis
  • Molecular biology
  • Chemistry
  • Life sciences
  • Environmental analysis
  • Material science
  • Semiconductor research

Key features

  • Excitation and emission wavelength range from 200 to 900 nm
  • Water Raman signal-to-noise ratio up to 20,000:1 RMS-BG
  • Scan speeds up to 60,000 nm/min
  • 150 W continuous xenon excitation source
  • Adjustable excitation and emission bandwidths
  • Excitation, emission and synchronous wavelength scanning
  • Fast 3D excitation-emission mapping
  • Quantitative and kinetic measurements
  • Fluorescence anisotropy measurements
  • Spectracle software for instrument control, analysis and reporting
  • Automatic instrument validation functions
  • Accessories for liquid, powder and thin-film samples

The FE30 uses a photomultiplier tube (PMT) detector with a detection range extending from 200 to 900 nm.

Specifications

Description
Excitation source: High Intensity 150 W Continuous Xenon Lamp
Wavelength measurement range: Excitation (EX) 200 – 900 nm, Emission (EM) 200 – 900 nm
Spectral bandwidth Excitation: 1, 2.5, 5, 10, 20 (5 steps), Emission: 1, 2.5, 5, 10, 20 (5 steps)
Wavelength accuracy: Excitation wavelength: ±1.5 nm, Emission wavelength: ±1.5 nm
Wavelength repeatability: Excitation wavelength: ±1 nm, Emission wavelength: ±1 nm
Sensitivity: RMS-PK = 1,000:1, RMS-BG = 20,000:1*
Optical platform: One-piece cast aluminium base. All optical components are fixed on the cast aluminium base to ensure instrument stability and collimation.
Wavelength scan speed: Max 60,000 nm/min; Selectable from 30, 60, 240, 600, 1200, 2400, 8000, 12,000, 30,000, 60,000 nm/min
Scan interval: 0.1 – 10.0 nm
Auto gain: 0-1,000 V adjustable
Fluorescence intensity drift: <1.5% Ex: 450 nm, Em: 450 nm (within 10 min)
Fluorescence value range: 0 to 50,000
Detector: Photomultiplier tube R928
Software: Spectracle PC-controlled software
Sample chamber dimension: 247 (W) × 215 (D) × 172 (H) mm
Instrument dimension (L×D×H): 660 (W) × 600 (D) × 250 (H) mm
Weight: 50 kg
*Standard water Raman measurement conditions: excitation wavelength = 350 nm, excitation and emission bandwidth = 10 nm, emission range = 360 – 450 nm, read interval = 1 nm, scan speed = 60 nm/min. Calculation based on the root mean square (RMS) method.

Ask about this instrument

SciSPX helps laboratories in Belgium, the Netherlands and Luxembourg find the right analytical instruments, with expert advice, installation, training and technical support.

Frequently asked questions

A fluorescence spectrometer measures the light emitted by a sample after it has absorbed light at a specific excitation wavelength. By recording excitation and emission spectra, fluorescence spectroscopy can be used for both qualitative sample characterisation and quantitative analysis.

The FE30 supports excitation, emission and synchronous wavelength scans, as well as kinetic time scans, 3D excitation-emission mapping, quantitative analysis and fluorescence anisotropy measurements. This makes it suitable for both routine fluorescence analysis and more advanced sample characterisation.
A 3D fluorescence scan measures fluorescence over a range of excitation and emission wavelengths to create an excitation-emission map. This provides an overview of the fluorescence characteristics of a sample and can be used for applications such as fluorescence fingerprinting and advanced modelling.
Yes. The FE30 supports quantitative analysis using calibration curves, including first- and second-order calibration. Once a calibration has been established using standards, it can be used to determine the response of unknown samples.
Yes. In addition to standard fluorescence cuvettes for liquid samples, the FE30 can be equipped with accessories for powders and thin films. A variable-angle solid sample holder and a micro powder sample holder are available for different solid-sample measurement requirements.

Downloads

Brochure FE30

Related instruments

FTIR spectrometer

IA30

FTIR spectrometer
double beam UV-Vis spectrophotometer

DB30

Double beam UV-Vis spectrophotometer

Last viewed products

No products found

Contact our Xperts

Prefer to give us a call?

The Netherlands
+31 (0)294 280 450

Belgium & Luxembourg
+32 (02)2 334 22 70