Edinburgh Analytical

DB30

Double beam UV-Vis spectrophotometer
Wavelength range from 190 to 1,100 nm
Scan speeds up to 6,000 nm/min
Selectable spectral bandwidths of 0.5, 1.0, 1.5, 2.0 and 4.0 nm

DB30

Double beam UV-Vis spectrophotometer

The DB30 is a double beam UV-Vis spectrophotometer designed for absorbance and transmittance measurements across the UV and visible spectrum. Covering a wavelength range from 190 to 1,100 nm, it combines selectable spectral bandwidths with fast scanning and flexible sample handling for routine analysis, research and quality-control applications.

The instrument can be operated directly through its integrated 7-inch touchscreen or controlled from a PC, allowing it to fit both standalone laboratory workflows and more advanced data-management environments.

Flexible UV-Vis measurements

The DB30 supports several measurement modes, allowing one instrument to handle different types of UV-Vis analysis.

Wavelength scanning

Absorbance, transmittance or detector signal can be measured across a selected wavelength range. Scan speed, wavelength increment and spectral bandwidth can be configured according to the measurement.

Time scan

For kinetic measurements, you can follow changes over time for measurement periods ranging from one minute to more than 27 hours.

Photometry

Measurements can be performed at individual wavelengths in either absorbance or transmittance mode. Up to ten individual wavelengths can be included in a measurement.

Quantitation

The built-in quantitation mode uses measurements from standard solutions to create calibration curves. Once the calibration has been established, the system calculates the concentrations of unknown samples from their absorbance values.

The touchscreen also includes application wizards for protein, nucleic acid and hexavalent chromium measurements.

Double beam optical system

The DB30 uses a Czerny-Turner double beam monochromator together with deuterium and tungsten-halogen light sources. The double beam configuration allows the sample and reference signals to be monitored during measurement, supporting stable measurements across the instrument’s wavelength range.

With selectable bandwidths from 0.5 to 4.0 nm, the system can be configured according to the spectral resolution required for a particular analysis. Scan speeds ranging from 10 to 6,000 nm/min provide additional flexibility between detailed spectral measurements and faster routine scanning.

UV measurements down to 190 nm

The DB30 covers wavelengths from 190 nm in the UV region through to 1,100 nm in the near-infrared region. Its photometric range extends from -3.4 to +3.4 Abs, enabling measurements across a broad absorbance range.

This makes the instrument suitable for samples and applications requiring measurements in the deeper UV region as well as conventional visible spectroscopy.

Touchscreen and PC operation

Every DB30 includes a touchscreen for standalone operation. Measurement setup, acquisition and data analysis can therefore be performed directly at the instrument without requiring a separate computer.

Data-processing functions available through the touchscreen include spectrum overlay, peak and trough analysis, smoothing, differentiation, arithmetic operations and area and rate calculations. Results can be stored internally or transferred using USB or SD card.

Sample handling and accessories

Depending on the application, it is possible to equip the DB30 for standard cuvettes, micro-volume samples, long-path measurements, temperature-controlled measurements, films, glass samples and continuous-flow analysis.

Available options include:

  • Standard 10 mm cell holder
  • Micro cell holder for 50 µl micro-volume cells
  • Long-path cell holder for 10–100 mm optical path lengths
  • Thermostatic cell holder
  • Electronic temperature-controlled cell holder
  • Six-position automatic cell holder
  • Micro flow cell
  • Auto sipper
  • Glass filter holder
  • Film holder
  • SpectroLink

Applications

The DB30 can be used for UV-Vis measurements across a broad range of laboratory environments, including:

  • Pharmaceutical analysis
  • Food analysis
  • Molecular biology
  • Chemistry
  • Life sciences
  • Environmental analysis
  • Petrochemical analysis

Key features

  • Double beam optical configuration
  • Wavelength range from 190 to 1,100 nm
  • Selectable spectral bandwidths of 0.5, 1.0, 1.5, 2.0 and 4.0 nm
  • Scan speeds up to 6,000 nm/min
  • Integrated 7-inch touchscreen for standalone operation
  • Automatic accessory recognition
  • Internal, USB and SD card data storage
  • Optional PC control and CFR-compliant software
  • Wide selection of sample holders and accessories

These features are supported by a Czerny-Turner double beam monochromator with tungsten-halogen and deuterium light sources.

Specifications

Description
Optics Czerny-Turner, Dual Beam Monochromator
Wavelength range 190 nm – 1100 nm
Spectral bandwidth 0.5 nm, 1 nm, 1.5 nm, 2 nm and 4 nm
Stray light ≤1% T (198 nm KCl, 340 nm) ≤0.05%T (220 nm, NaI, 340 nm, NaNO2)
Wavelength accuracy ±0.1 nm D2 peak 656.1 nm, ± 0.25 nm entire range
Wavelength repeatability ±0.1 nm (Max deviation), ≤0.05 nm (Standard deviation)
Photometric range Absorbance: -3.4 to +3.4, %T: 0 to 300, Concentration: 0,000 to 9,999
Photometric accuracy ±0.002 Abs (0 – 0.5 Abs), ±0.004 Abs (0.5 – 1.0 Abs), ±0.008 Abs (1.0 – 2.0 Abs) ±0.3% T
Photometric reproducibility ±0.0005 Abs (0.5 Abs), ±0.001 Abs (1.0 Abs), ±0.004 Abs (2.0 Abs)
Wavelength scan speed 10, 100, 200, 400, 800, 1200, 2400, 3600, 6000 nm/min
RMS noise 0.0001 Abs (Peak-to-peak) 0.00005 Abs (RMS)
Baseline stability <0.0003 Abs/hr (500 nm, 2 hour lamp warm-up period)
Baseline flatness ±0.0009 Abs (200 nm – 950 nm)
Light source Tungsten-Halogen and Deuterium Lamps
Light source switching Automatic switching selectable for 325 nm – 370 nm range
Detector Silicon Photodiode
Display 7” Touchscreen
Software Touchscreen operation, PC-controlled software or CFR compliant PC-controlled software
Dimensions 500 mm (W) × 475 mm (D) × 250 mm (H)
Net weight 20 kg (approx.)
Power supply 100 – 240V, 50/60 Hz, 150VA
Ambient temperature 10°C – 35°C
Output device USB flash drive, SD card
Interface USB PC interface

Ask about this instrument

SciSPX helps laboratories in Belgium, the Netherlands and Luxembourg find the right analytical instruments, with expert advice, installation, training and technical support.

Frequently asked questions

A double beam UV-Vis spectrophotometer measures the absorption or transmission of ultraviolet and visible light by a sample. In a double beam system, light is directed through both a sample and a reference path. This allows the reference signal to be monitored alongside the sample measurement and helps maintain a stable baseline during analysis.

The DB30 can measure absorbance, transmittance and detector signal as a function of wavelength. It also supports wavelength scans, kinetic time scans, photometric measurements and quantitative analysis using calibration curves.
Yes. The DB30 includes a quantitation mode for determining the concentration of unknown samples. Measurements from standards are used to establish a calibration curve, which can then be used to calculate concentrations from the measured response of unknown samples. The instrument supports calibration curves including second-order and multi-wavelength data points.

Yes. The DB30 includes a 7-inch touchscreen that provides standalone control of measurement setup, data acquisition and analysis. For laboratories that prefer PC-based operation or require additional data-management capabilities, PC-control software is also available.
The DB30 supports different sample formats through interchangeable accessories. Options are available for standard cuvettes, micro-volume samples, long-path cells, films, glass samples, flow measurements and temperature-controlled measurements. This allows the instrument to be adapted to different analytical workflows and sample requirements.

Downloads

Brochure DB30

Related instruments

FTIR spectrometer

IA30

FTIR spectrometer
Fluorescence spectrometer

FE30

High-sensitivity fluorescence spectrometer

Last viewed products

No products found

Contact our Xperts

Prefer to give us a call?

The Netherlands
+31 (0)294 280 450

Belgium & Luxembourg
+32 (02)2 334 22 70