Compact refractometer with intuitive touchscreen
The ATR V by Schmidt & Haensch is a compact, stand-alone critical angle refractometer designed for reliable routine analysis in both laboratory and production environments. It combines robust construction with user-friendly operation and is suitable for applications ranging from basic Brix measurements to more specialized analytical tasks.
Why choose the ATR V for routine laboratory work?
Because it is designed to deliver stable and precise results with minimal effort:
- Requires only a small sample volume
- Provides fast and reliable measurement results
- Offers a strong price-performance ratio
- Operates as a stand-alone system with intuitive touchscreen control
The flat and compact sample chamber supports easy cleaning, making it suitable for daily use in routine environments.
Temperature control
There are two available configurations:
- With integrated Peltier temperature control
- Without temperature control
The optional Peltier system ensures precise thermal regulation for temperature-sensitive samples and removes the need for external tempering or time-consuming sample preparation. A temperature-compensated sugar scale further supports reliable results, especially in sugar-related applications.
Applications
The system is used across multiple industries for concentration measurement, identification, and quality control.
In the chemical industry:
- Solvents
- Organic polymers
- Distilled products
- Solutions of inorganic compounds
In the food and beverage industry:
- Yoghurt, jam, fruit extracts, syrup, honey
- Coffee extract, vegetable fat, chocolate, milk, baby food
- Soft drinks, fruit juice, wine, beer
In medical applications:
- Serum
- Blood
- Urine
In the petrochemical industry:
- Oils, fats, waxes
- Naphthalenes
- Raw oils, varnishes, paints
Measurement scales
It supports a range of commonly used refractometric scales:
- Brix (°Bx)
- Degree Plato (°Plato)
- Oechsle scale
- Refractive Index (RI)
- Refractometric Dry Substance (RDS)
- Sugar-related measurements
- Concentration and dilution of soft drinks
- Ripeness of fruits and vegetables
Features
- Robust measuring prism for consistent performance
- Flat sample chamber for easy cleaning
- Stable and precise measurements
- Interfaces for seamless data transfer and documentation
- High-resolution touchscreen for intuitive operation
- Aquisys 3 software delivers measurement data within seconds
- Operation possible directly on the device or via external devices (tablet, PC, smartphone)
- User-defined scales can be created and stored
Available models
| Specification | ATR V 301 | ATR VT 301 | ATR VT 401 | ATR VT 501 |
|---|---|---|---|---|
| Light source / wavelength | LED, interference filter 589 nm | LED, interference filter 589 nm | LED, interference filter 589 nm | LED, interference filter 589 nm |
| Measuring scales | Refractive Index (RI) Sucrose (Brix) Standard scales included |
Same as ATR V 301 | Same as ATR V 301 | Same as ATR V 301 |
| Measuring range | 1.3200–1.5800 RI 0–100 Brix |
1.3200–1.5800 RI 0–100 Brix |
1.30000–1.66000 RI 0–100 Brix |
1.27000–1.71000 RI 0–100 Brix |
| Accuracy | ± 0.0001 RI ± 0.05 Brix |
± 0.0001 RI ± 0.05 Brix |
± 0.00003 RI ± 0.02 Brix |
± 0.00002 RI ± 0.015 Brix |
| Reproducibility (precision) | ± 0.0001 RI ± 0.05 Brix |
± 0.0001 RI ± 0.05 Brix |
± 0.00001 RI ± 0.01 Brix |
± 0.00001 RI ± 0.01 Brix |
| Resolution | 0.0001 RI 0.05 Brix |
0.0001 RI 0.05 Brix |
0.00001 RI 0.01 Brix |
0.00001 RI 0.01 Brix |
| Temperature control | Integrated Peltier sample temperature control system | Integrated Peltier sample temperature control system | Integrated Peltier sample temperature control system | Integrated Peltier sample temperature control system |
| Temperature control range | −10 °C to 60 °C | 5 °C to 80 °C | 5 °C to 100 °C | 5 °C to 100 °C |
| Extended temperature range (optional) | — | — | −5 °C to +105 °C | −5 °C to +105 °C |
| Temperature stabilization time | 25 °C → 20 °C (± 0.1 °C) in 1 min (ambient temperature 20 °C) |
Same as ATR V 301 | Same as ATR V 301 | Same as ATR V 301 |
| Automatic temperature compensation | Automatic temperature compensation for Brix according to ICUMSA and other temperature‑compensated scales | Same as ATR V 301 | Same as ATR V 301 | Same as ATR V 301 |
| Temperature sensor | 4‑wire Pt1000 sensor located inside prism | Same as ATR V 301 | Same as ATR V 301 | Same as ATR V 301 |
| Temperature sensor accuracy / resolution | 0.1 °C / 0.01 °C | Same as ATR V 301 | Same as ATR V 301 | Same as ATR V 301 |
| Ambient temperature | 5 °C to 40 °C | Same as ATR V 301 | Same as ATR V 301 | Same as ATR V 301 |
| Minimum sample volume | 600 µL < 10 µL with micro‑volume insert |
Same as ATR V 301 | Same as ATR V 301 | Same as ATR V 301 |
| Sample compartment / wetted parts | Sapphire FFKM Stainless steel 1.4404 (Hastelloy optional) |
Same as ATR V 301 | Same as ATR V 301 | Same as ATR V 301 |
| Housing material | Aluminium | Aluminium | Aluminium | Aluminium |