CEM

EDGE PFAS

Automated extraction system for the preparation of solid and semi-solid samples for PFAS analysis
Meets the requirements of EPA method 1633
All components in contact with sample are tested to be PFAS-free
Reduces the time required for SPE clean-up

EDGE PFAS

Automated extraction system for PFAS analysis

The EDGE PFAS is an automated extraction system that exists for the preparation of solid and semi-solid samples for PFAS analysis. The system performs the complete extraction workflow, including extraction, filtration, cooling, and washing, faster than traditional PFAS solvent extraction methods.

The system exists without PFAS-containing materials in components that come into contact with the sample, helping laboratories perform PFAS extractions without concerns about background contamination. The EDGE PFAS also meets the performance criteria of EPA Method 1633.

Automated PFAS extraction workflow

The EDGE PFAS automates multiple steps of the sample preparation process. Place the sample in the Q-Cup, select the appropriate method, and start the extraction using the integrated touchscreen.

The system automatically adds the solvent, performs the extraction, filters the extract, cools the sample, and completes an extensive washing step before loading the next sample. Once the extraction is complete, the extract can be taken directly for analysis.

The system supports both pre-programmed One Touch methods and user-defined methods, allowing laboratories to select the workflow that best suits their application.

It is possible to program up to 12 samples for automated processing, allowing laboratory staff to perform other tasks while the system completes the extraction sequence.

PFAS-free sample pathway

The EDGE PFAS is designed to minimize the risk of PFAS background contamination during sample preparation. Polypropylene tubing, centrifuge tubes, and a side enclosure provide a PFAS-free environment for sample handling.

In addition, the Q-Cups and Q-Discs have been tested to be PFAS-free, while all components that come into contact with the sample are tested to ensure they do not contain PFAS.

eCleanUP for PFAS sample preparation

The EDGE PFAS can be used with eCleanUP, a sorbent that has been tested to be free of PFAS.

During the extraction process, eCleanUP helps remove both water and impurities from the extraction mixture. For optimal results, it is added together with the sample before extraction.

Sample compatibility

The EDGE PFAS is suitable for a wide range of sample types, including:

  • Environmental samples
  • Food samples
  • Consumer products
  • Cosmetics

Regardless of the sample type, the system produces a particle-free extract collected in a PFAS-free centrifuge tube, ready for analysis.

Simplified PFAS sample preparation

By automating solvent addition, extraction, filtration, cooling, and washing within a single workflow, the EDGE PFAS reduces manual handling throughout the sample preparation process. The automated workflow helps reduce operator error, minimizes potential contamination sources, and allows laboratory personnel to spend less time on routine extraction procedures.

The EDGE PFAS combines automated extraction, PFAS-free sample contact materials, and support for EPA Method 1633 workflows to provide efficient and reliable PFAS sample preparation for solid and semi-solid samples.

Q-Cup Sample Holder

A simple solution to a complicated problem

The aluminum Q-Cup sample holder consists of three easy-to-assemble pieces.

1. Q-Cup Cylinder
2. Q-Disc®
3. Threaded Bottom
The open top creates a dispersive effect which promotes rapid extraction and filtration. The disposable Q-Disc filters your sample prior to analysis. Its simple
design lends itself to easy cleaning.

 

Automated PFAS extraction process

Touch “start” to begin the automated process

Automated Extraction Process

  1. Select a method
    Load a rack of Q-cups containing samples into the EDGE. Then, select the proper method, program the number of samples, and press “Start”.
  2. Autosampler loads sample
    The autosampler automatically loads the Q-Cup into the chamber, sealing it with the pressure cap.
  3. Matrix is extracted
    Solvent is added through the top of the Q-Cup to wet the sample. As the chamber walls heat up, the increased pressure forces the solvent into the sample.
  4. Extract is collected
    Once the sample reaches temperature, the solvent filters through the Q-Disc, passes through the cooling coil, and into a collection vial.

Key features

  • Automated extraction for solid and semi-solid samples
  • Meets the performance criteria of EPA Method 1633
  • Components in contact with the sample are tested to be PFAS-free
  • Reduces the time required for SPE clean-up
  • Compatible with a wide variety of sample types
  • Easy-to-assemble and easy-to-clean Q-Cup sample holders

Ask about this instrument

SciSPX helps laboratories in Belgium, the Netherlands and Luxembourg find the right analytical instruments, with expert advice, installation, training and technical support.

Frequently asked questions

PFAS analysis is the detection and quantification of per- and polyfluoroalkyl substances, a group of persistent synthetic chemicals commonly found in environmental samples, food, consumer products, and industrial materials.
PFAS sample preparation is critical because contamination can occur easily during extraction and handling. Accurate sample preparation helps ensure reliable PFAS measurements and supports regulatory compliance.
The EDGE PFAS automatically adds solvent, performs extraction, filters the extract, cools the sample, and completes a washing cycle before processing the next sample. This reduces manual handling and improves reproducibility.
PFAS compounds are commonly found in many laboratory materials. Using PFAS-free components helps prevent background contamination that could affect analytical results and lead to inaccurate measurements.

EPA Method 1633 is a standardized analytical method for the determination of PFAS in environmental matrices. It includes requirements for sample preparation, extraction, cleanup, and instrumental analysis.

The system can process up to 12 samples in a fully automated sequence, allowing laboratory personnel to focus on other tasks while extraction is underway.

Downloads

Brochure CEM Edge PFAS

Related instruments

Microwave laboratory digestion system

MARS 6

The easiest, safest and most intelligent microwave digestion system on the market
Microwave PFAS extraction system

MARS 6 PFAS

Microwave extraction system designed for high-throughput PFAS sample preparation
Microwave Digestion System

Blade

Designed to simplify elemental sample preparation while increasing laboratory throughput

Last viewed products

No products found

Contact our Xperts

Prefer to give us a call?

The Netherlands
+31 (0)294 280 450

Belgium & Luxembourg
+32 (02)2 334 22 70