Edge PFAS

Fast and simple automated solvent extraction system.
Meets the requirements of EPA method 1633
All components in contact with sample are tested to be PFAS-free
Reduces the time needed for SPE clean up
Sample holders are easily assembled and cleaned (Q-Cups)

Edge PFAS

The EDGE® PFAS is an automated extraction system that is applicable to solid and semi-solid sample types for PFAS analysis. Perform a complete extraction (including filtering, cooling, and washing) faster than traditional methods. The EDGE PFAS has revolutionized the extraction process for PFAS sample preparation.

The EDGE PFAS™ system does not contain any PFAS-containing materials, enabling the rapid extraction of PFAS without the worry of background contamination.

 

 Efficient PFAS Extraction

Automation Simplifies PFAS Workflow.

The automated addition of solvent, followed by complete extraction and automated filtration, makes EDGE PFAS the most efficient PFAS system available. Add the sample to the Q-Cup, choose the method, and press start. Once complete, take the extract directly to analysis, reducing operator error, possible contamination sources, and freeing lab time for other tasks.

Flexible

Get better results with one instrument.

  • Environmental
  • Food
  • Consumer Products
  • Cosmetics

Regardless of sample type, the EDGE PFAS can extract it. The EDGE PFAS system delivers a particle-free solution in a PFAS-free centrifuge tube, ready for analysis for all of these samples and more.

Q-Cup® Sample Holder

A simple solution to a complicated problem.

The aluminum Q-Cup sample holder consists of three easy-to-assemble pieces.

1. Q-Cup Cylinder
2. Q-Disc®
3. Threaded Bottom
The open top creates a dispersive effect which promotes rapid extraction and filtration. The disposable Q-Disc filters your sample prior to analysis. The simple design lends itself to easy cleaning.

Automated Extraction Process

Touch “start” to begin the automated process.

 

  1. Select a Method
    After a rack of Q-Cups containing samples are loaded into the EDGE, simply select the proper method, program the number of samples, and hit “Start”.
  2. Autosampler Loads Sample
    The Q-Cup is automatically loaded into the chamber by the autosampler. The pressure cap then creates a pressurized seal on the top of the Q-Cup.
  3. Matrix is Extracted
    Solvent is added through the top of the Q-Cup to wet the sample.
    As the chamber walls are heated, the pressure in the gap increases. This overcomes the pressure inside the Q-Cup, forcing the solvent to disperse into the sample.
  4. Extract is Collected
    Once the sample reaches temperature, the solvent is filtered through the Q-Disc, the cooling coil, and into a collection vial.

eCleanUP

Super sorbent saves time.

eCleanUP is tested to not contain PFAS and will aid in the removal of both water and impurities during the PFAS extraction process. Add it to each extraction mixture with the sample for best results.

 

Read our blogposts:

Related instruments

MARS 6

The easiest, safest and most intelligent microwave digestion system on the market.
Contactless in-situ temperature measurement
Sensors that detect vessel type and count

MARS 6 PFAS

High throughput Microwave PFAS extraction system
All components in contact with sample are tested to be PFAS-free
Meets the requirements of EPA method 1633