CEM

Sprint

Rapid protein analyzer that enables fast protein analysis in food and dairy samples
Direct method for protein conversion
No hazardous chemicals
Safer and less expensive than Kjeldahl

Sprint

Rapid protein analyzer

The CEM Sprint Rapid Protein Analyzer provides fast, direct protein determination in food and dairy products. Using proprietary iTag protein-tagging technology, the instrument measures protein rather than total nitrogen. This approach distinguishes protein from non-protein nitrogen (NPN) and delivers results in less than five minutes.

Sprint offers an alternative to conventional Kjeldahl and combustion methods for suitable food applications. Its rapid analysis supports quality control, raw material evaluation, and production monitoring.

How does the Sprint protein analyzer work? 

Unlike Kjeldahl and Dumas combustion methods, which determine protein indirectly from nitrogen content, Sprint measures protein through a chemical tagging reaction.

The system uses CEM’s proprietary iTag technology to bind a reagent to proteins in the sample. The analytical process involves several steps:

  1. A predetermined amount of iTag solution is added to the sample and homogenized to release the proteins.
  2. The iTag molecules bind to the proteins and are removed from the solution.
  3. The remaining unbound iTag passes through a disposable filter into the built-in colorimeter.
  4. The system determines the amount of iTag bound to the proteins and displays the protein result.

This approach enables direct protein analysis without relying on a nitrogen-to-protein conversion factor.

Direct protein analysis vs. Kjeldahl 

Kjeldahl and Dumas methods measure nitrogen and calculate protein content using a conversion factor. However, some samples contain non-protein nitrogen compounds that can contribute to the measured nitrogen content.

Sprint uses protein-tagging chemistry to distinguish protein from non-protein nitrogen. This reduces interference from nitrogen-containing compounds such as melamine.

The following manufacturer data compares Sprint and Kjeldahl measurements in fluid milk containing added melamine:

Sample Kjeldahl Protein Sprint Protein
Fluid milk 3.3% 3.3%
Fluid milk with 0.1% added melamine 3.7% 3.3%
Fluid milk with 0.5% added melamine 5.1% 3.3%
Fluid milk with 1.0% added melamine 8.6% 3.4%

In these results, added melamine increases the apparent protein content determined by Kjeldahl. Sprint maintains approximately the same protein result across the tested samples.

These results illustrate the difference between nitrogen-based and direct protein measurement. They do not establish universal performance across every sample matrix or potential interferent.

Rapid protein determination without hazardous waste

Sprint uses non-toxic iTag solutions and does not generate hazardous waste during analysis. The system uses disposable sample cups and filters to simplify sample handling. After each measurement, Sprint automatically cleans its internal components. Operators can then discard the used sample materials.

This workflow reduces manual cleaning and avoids the concentrated acids required for conventional Kjeldahl digestion.

Simple operation and preprogrammed methods

Sprint combines automated analysis with preprogrammed methods for a wide range of food samples. Operators select the appropriate method, weigh the sample into a disposable cup, and place it in the instrument with a filter. Sprint then performs the analysis and displays the protein result.

The software can store hundreds of methods and tens of thousands of sample results. Downloadable iMethods are also available.

Protein analysis applications

Sprint features pre-programmed methods, including:

  • Dairy products: fluid milk, milk powders, cheese, yogurt, cream, and whey
  • Meat and poultry: beef, pork, chicken, turkey, and processed meat products
  • Plant-based foods: soybeans, tofu, soy beverages, and hummus
  • Other food products: eggs, wheat flour, infant formula, nutritional drinks, and prepared foods
  • Pet food: wet pet food formulations

Applications and methods

Sprint exists for protein analysis in food and dairy applications. The system automates the following AOAC Official Methods:

  • AOAC 967.12
  • AOAC 930.33
  • AOAC 930.29
  • AOAC 2011.04

Key features

  • Rapid analysis: delivers protein results in less than five minutes
  • Non-protein nitrogen differentiation: reduces interference from NPN compounds, including melamine
  • Green chemistry: uses non-toxic reagents without generating hazardous waste
  • Disposable consumables: sample cups and filters simplify handling and disposal
  • Automatic self-cleaning: cleans internal components after each analysis
  • Preprogrammed methods: supports a broad range of food and dairy samples
  • Method and result storage: stores hundreds of methods and tens of thousands of results
  • AOAC methods: automates AOAC Official Methods 967.12, 930.33, 930.29, and 2011.04

Ask about this instrument

SciSPX helps laboratories in Belgium, the Netherlands and Luxembourg find the right analytical instruments, with expert advice, installation, training and technical support.

Frequently asked questions

Sprint determines protein content directly using CEM’s proprietary iTag protein-tagging technology. Unlike nitrogen-based methods, it does not calculate protein content from total nitrogen.

Kjeldahl determines nitrogen content and converts it into a protein result. Sprint measures protein directly using a chemical tagging reaction. This helps distinguish protein from non-protein nitrogen compounds.

Sprint delivers protein results in less than five minutes. This makes it suitable for rapid testing in food laboratories and production environments.

Yes. Sprint supports protein determination in various dairy products, including milk, cheese, yogurt, cream, and whey. The appropriate analytical method depends on the sample matrix.

Non-protein nitrogen refers to nitrogen-containing compounds that are not proteins, including urea, ammonia, nucleic acids, and certain food additives. These compounds contribute to total nitrogen measurements but do not contribute to true protein content.

No. Sprint uses non-toxic iTag solutions and does not generate hazardous waste during analysis.

Downloads

Brochure SPRINT

Related instruments

Microwave muffle furnace

Phoenix BLACK

The world’s safest and fastest muffle furnace
Microwave moisture analyzer

SMART 6

Rapid microwave and infrared moisture and solids analyzer for direct loss-on-drying measurements in wet and dry samples
Rapid fat analyzer in compliance with ISO 16756

Oracle

Get an accurate analysis of the fat content of any food sample in only 30 seconds

Last viewed products

No products found

Contact our Xperts

Prefer to give us a call?

The Netherlands
+31 (0)294 280 450

Belgium & Luxembourg
+32 (02)2 334 22 70