{"id":5094,"date":"2026-04-22T16:22:21","date_gmt":"2026-04-22T14:22:21","guid":{"rendered":"https:\/\/scispx.com\/?page_id=5094"},"modified":"2026-04-23T09:36:50","modified_gmt":"2026-04-23T07:36:50","slug":"een-nieuwe-fluorometrische-benadering-voor-utlra-lage-ammoniakanalyse","status":"publish","type":"page","link":"https:\/\/scispx.com\/nl\/een-nieuwe-fluorometrische-benadering-voor-utlra-lage-ammoniakanalyse\/","title":{"rendered":"Een nieuwe fluormetrische aanpak voor ammoniakanalyse bij ultralaag ammoniakgehalte"},"content":{"rendered":"<div data-elementor-type=\"wp-page\" data-elementor-id=\"5094\" class=\"elementor elementor-5094\" data-elementor-post-type=\"page\">\n\t\t\t\t<div class=\"elementor-element elementor-element-4bfefe08 e-flex e-con-boxed e-con e-parent\" data-id=\"4bfefe08\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;,&quot;jet_parallax_layout_list&quot;:[]}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-29352a2e e-con-full e-flex e-con e-child\" data-id=\"29352a2e\" data-element_type=\"container\" data-settings=\"{&quot;jet_parallax_layout_list&quot;:[]}\">\n\t\t<div class=\"elementor-element elementor-element-1caf187f e-con-full e-flex e-con e-child\" data-id=\"1caf187f\" data-element_type=\"container\" data-settings=\"{&quot;jet_parallax_layout_list&quot;:[]}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-42982fa4 elementor-widget elementor-widget-heading\" data-id=\"42982fa4\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">Nieuwe analytische fluorometer <\/h1>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-db5464b elementor-widget elementor-widget-text-editor\" data-id=\"db5464b\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>Zeer gevoelige fluorimeter die kan worden gecombineerd met gesegmenteerde flowanalyzers<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-74d48798 e-con-full e-flex e-con e-child\" data-id=\"74d48798\" data-element_type=\"container\" data-settings=\"{&quot;jet_parallax_layout_list&quot;:[]}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-59036910 elementor-widget elementor-widget-button\" data-id=\"59036910\" data-element_type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"https:\/\/scispx.com\/nl\/contact\/\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Contacteer ons<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-26ad7749 e-con-full e-flex e-con e-child\" data-id=\"26ad7749\" data-element_type=\"container\" data-settings=\"{&quot;jet_parallax_layout_list&quot;:[]}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-42eda9c0 elementor-widget elementor-widget-image\" data-id=\"42eda9c0\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"800\" height=\"420\" src=\"https:\/\/scispx.com\/wp-content\/uploads\/2026\/04\/LinkedIn-SciSPX-48-1024x538.png\" class=\"attachment-large size-large wp-image-5097\" alt=\"fluorometer\" srcset=\"https:\/\/scispx.com\/wp-content\/uploads\/2026\/04\/LinkedIn-SciSPX-48-1024x538.png 1024w, https:\/\/scispx.com\/wp-content\/uploads\/2026\/04\/LinkedIn-SciSPX-48-300x158.png 300w, https:\/\/scispx.com\/wp-content\/uploads\/2026\/04\/LinkedIn-SciSPX-48-768x403.png 768w, https:\/\/scispx.com\/wp-content\/uploads\/2026\/04\/LinkedIn-SciSPX-48-18x9.png 18w, https:\/\/scispx.com\/wp-content\/uploads\/2026\/04\/LinkedIn-SciSPX-48.png 1200w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-70133dc2 e-flex e-con-boxed e-con e-parent\" data-id=\"70133dc2\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;,&quot;jet_parallax_layout_list&quot;:[]}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-52bc8389 e-con-full e-flex e-con e-child\" data-id=\"52bc8389\" data-element_type=\"container\" data-settings=\"{&quot;jet_parallax_layout_list&quot;:[]}\">\n\t\t<div class=\"elementor-element elementor-element-c91e0d6 e-con-full e-flex e-con e-child\" data-id=\"c91e0d6\" data-element_type=\"container\" data-settings=\"{&quot;jet_parallax_layout_list&quot;:[]}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-4bd95e6b elementor-widget elementor-widget-heading\" data-id=\"4bd95e6b\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Korte samenvatting<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3304687 elementor-widget elementor-widget-button\" data-id=\"3304687\" data-element_type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"https:\/\/scispx.com\/nl\/brands\/seal\/\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Ontdek SEAL Analytical<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-5a2f099 e-con-full e-flex e-con e-child\" data-id=\"5a2f099\" data-element_type=\"container\" data-settings=\"{&quot;jet_parallax_layout_list&quot;:[]}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-6951a5d3 elementor-widget elementor-widget-text-editor\" data-id=\"6951a5d3\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p><em>De nieuwe SEAL Analytical fluorimeter is een zeer gevoelige fluorimeter die kan worden gecombineerd met gesegmenteerde flowanalyzers van SEAL. Het maakt gebruik van de OPA fluorescentiemethode om ammoniak in zeewater te detecteren tot 2 nMol, terwijl zoutgerelateerde interferenties die optreden bij traditionele Berthelot kleurmethoden volledig worden ge\u00eblimineerd<\/em><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-68c8a9c e-con-full e-flex e-con e-parent\" data-id=\"68c8a9c\" data-element_type=\"container\" data-settings=\"{&quot;jet_parallax_layout_list&quot;:[]}\">\n\t\t<div class=\"elementor-element elementor-element-4776112f e-flex e-con-boxed e-con e-child\" data-id=\"4776112f\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;,&quot;jet_parallax_layout_list&quot;:[]}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-7ca04ac7 e-con-full e-flex e-con e-child\" data-id=\"7ca04ac7\" data-element_type=\"container\" data-settings=\"{&quot;jet_parallax_layout_list&quot;:[]}\">\n\t\t<div class=\"elementor-element elementor-element-7aa5eb40 e-con-full e-flex e-con e-child\" data-id=\"7aa5eb40\" data-element_type=\"container\" data-settings=\"{&quot;jet_parallax_layout_list&quot;:[]}\">\n\t\t<div class=\"elementor-element elementor-element-7d085672 e-con-full e-flex e-con e-child\" data-id=\"7d085672\" data-element_type=\"container\" data-settings=\"{&quot;jet_parallax_layout_list&quot;:[]}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-e82662a elementor-widget elementor-widget-heading\" data-id=\"e82662a\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Een nieuwe fluorometrische benadering voor ultra lage ammoniakanalyse in SFA<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3ccbb5f4 elementor-widget elementor-widget-text-editor\" data-id=\"3ccbb5f4\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>Voor laboratoria die werken met zeer lage ammoniakconcentraties, met name in zeewater en andere matrices met een hoog zoutgehalte, vormen traditionele kleurmetrische methoden vaak een grote analytische uitdaging. Verschillen in brekingsindex, matrix effecten door zouten en de complexiteit van multi reagenschemie maken betrouwbare ammoniakbepaling op laag niveau moeilijk.<\/p><p>Om deze beperkingen te overwinnen, heeft SEAL Analytical een nieuwe fluorimeter ontwikkeld die speciaal is ontworpen voor gesegmenteerde flow analysesystemen.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-45b7fa05 e-con-full e-flex e-con e-child\" data-id=\"45b7fa05\" data-element_type=\"container\" data-settings=\"{&quot;jet_parallax_layout_list&quot;:[]}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-11efeedb elementor-widget elementor-widget-image\" data-id=\"11efeedb\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"800\" height=\"534\" src=\"https:\/\/scispx.com\/wp-content\/uploads\/2025\/07\/pexels-fotios-photos-734973-1024x683.jpg\" class=\"attachment-large size-large wp-image-4272\" alt=\"\" srcset=\"https:\/\/scispx.com\/wp-content\/uploads\/2025\/07\/pexels-fotios-photos-734973-1024x683.jpg 1024w, https:\/\/scispx.com\/wp-content\/uploads\/2025\/07\/pexels-fotios-photos-734973-300x200.jpg 300w, https:\/\/scispx.com\/wp-content\/uploads\/2025\/07\/pexels-fotios-photos-734973-768x512.jpg 768w, https:\/\/scispx.com\/wp-content\/uploads\/2025\/07\/pexels-fotios-photos-734973-1536x1024.jpg 1536w, https:\/\/scispx.com\/wp-content\/uploads\/2025\/07\/pexels-fotios-photos-734973-2048x1365.jpg 2048w, https:\/\/scispx.com\/wp-content\/uploads\/2025\/07\/pexels-fotios-photos-734973-18x12.jpg 18w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-21d393e7 e-con-full e-flex e-con e-child\" data-id=\"21d393e7\" data-element_type=\"container\" data-settings=\"{&quot;jet_parallax_layout_list&quot;:[]}\">\n\t\t<div class=\"elementor-element elementor-element-1facf532 e-con-full e-flex e-con e-child\" data-id=\"1facf532\" data-element_type=\"container\" data-settings=\"{&quot;jet_parallax_layout_list&quot;:[]}\">\n\t\t<div class=\"elementor-element elementor-element-65f4be1b e-con-full e-flex e-con e-child\" data-id=\"65f4be1b\" data-element_type=\"container\" data-settings=\"{&quot;jet_parallax_layout_list&quot;:[]}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-1d2a0eba elementor-widget elementor-widget-heading\" data-id=\"1d2a0eba\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Waarom presteert de OPA fluorometrische methode beter dan colorimetrische ammoniakanalyse? <\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3d00cd88 elementor-widget elementor-widget-text-editor\" data-id=\"3d00cd88\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>De nieuwe detector is gebaseerd op de o ftaalaldehyde (OPA) fluorescentiemethode voor ammoniakbepaling. Hierbij reageert ammoniak met OPA in aanwezigheid van een boraatbuffer en natriumsulfiet, waarbij een fluorescerende verbinding ontstaat die met zeer hoge gevoeligheid kan worden gemeten.<\/p><p>In tegenstelling tot traditionele kleurmetrische methoden zoals de Berthelot  of fenolmethode, wordt de OPA fluorimetrische techniek niet be\u00efnvloed door verschillen in brekingsindex veroorzaakt door het zoutgehalte. Dit is bijzonder belangrijk voor toepassingen in zeewater, waar het zoutgehalte per monster kan vari\u00ebren.<\/p><p>Daarnaast vereenvoudigt de fluorometrische aanpak het gebruik van reagentia: er zijn minder reagentia nodig dan bij conventionele kleurmeting, die vaak meerdere componenten en strikt gecontroleerde reactieomstandigheden (zoals bijvoorbeeld de pH) vereisen.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-13509a8b e-con-full e-flex e-con e-parent\" data-id=\"13509a8b\" data-element_type=\"container\" data-settings=\"{&quot;jet_parallax_layout_list&quot;:[]}\">\n\t\t<div class=\"elementor-element elementor-element-2ec3ba9 e-flex e-con-boxed e-con e-child\" data-id=\"2ec3ba9\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;,&quot;jet_parallax_layout_list&quot;:[]}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-e782b4a e-con-full e-flex e-con e-child\" data-id=\"e782b4a\" data-element_type=\"container\" data-settings=\"{&quot;jet_parallax_layout_list&quot;:[]}\">\n\t\t<div class=\"elementor-element elementor-element-558e278a e-con-full e-flex e-con e-child\" data-id=\"558e278a\" data-element_type=\"container\" data-settings=\"{&quot;jet_parallax_layout_list&quot;:[]}\">\n\t\t<div class=\"elementor-element elementor-element-b3e64fc e-con-full e-flex e-con e-child\" data-id=\"b3e64fc\" data-element_type=\"container\" data-settings=\"{&quot;jet_parallax_layout_list&quot;:[]}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-18c8d03d elementor-widget elementor-widget-heading\" data-id=\"18c8d03d\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Integratie van de fluorometer met AA500  en QuAAtro39 systemen <\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4905ef04 elementor-widget elementor-widget-text-editor\" data-id=\"4905ef04\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>De fluorometer is specifiek ontwikkeld voor gebruik met SEAL gesegmenteerde flow analysatoren, en niet aangepast voor instrumenten van derden.<\/p><p>Hij wordt ge\u00efntegreerd als standaard detectormodule in de SEAL Analytical AA500 en is daarnaast compatibel met QuAAtro39 systemen en oudere AA3 systemen als standalone module.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-1320db94 e-con-full e-flex e-con e-child\" data-id=\"1320db94\" data-element_type=\"container\" data-settings=\"{&quot;jet_parallax_layout_list&quot;:[]}\">\n\t\t<div class=\"elementor-element elementor-element-d880536 e-grid e-con-full e-con e-child\" data-id=\"d880536\" data-element_type=\"container\" data-settings=\"{&quot;jet_parallax_layout_list&quot;:[]}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-375cfca elementor-align-center elementor-widget elementor-widget-button\" data-id=\"375cfca\" data-element_type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"https:\/\/scispx.com\/nl\/instruments\/aa500-geautomatiseerde-segmented-flow-analyzer\/\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Ontdek de AA500<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-02720e7 elementor-align-center elementor-widget elementor-widget-button\" data-id=\"02720e7\" data-element_type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"https:\/\/scispx.com\/nl\/instruments\/quaatro39-autoanalyzer\/\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Ontdek de QuAAtro39<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-4051a01 e-con-full e-flex e-con e-child\" data-id=\"4051a01\" data-element_type=\"container\" data-settings=\"{&quot;jet_parallax_layout_list&quot;:[]}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-22b07de6 elementor-widget elementor-widget-image\" data-id=\"22b07de6\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"800\" height=\"420\" src=\"https:\/\/scispx.com\/wp-content\/uploads\/2026\/04\/LinkedIn-SciSPX-49-1024x538.png\" class=\"attachment-large size-large wp-image-5107\" alt=\"\" srcset=\"https:\/\/scispx.com\/wp-content\/uploads\/2026\/04\/LinkedIn-SciSPX-49-1024x538.png 1024w, https:\/\/scispx.com\/wp-content\/uploads\/2026\/04\/LinkedIn-SciSPX-49-300x158.png 300w, https:\/\/scispx.com\/wp-content\/uploads\/2026\/04\/LinkedIn-SciSPX-49-768x403.png 768w, https:\/\/scispx.com\/wp-content\/uploads\/2026\/04\/LinkedIn-SciSPX-49-18x9.png 18w, https:\/\/scispx.com\/wp-content\/uploads\/2026\/04\/LinkedIn-SciSPX-49.png 1200w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-100f29a0 e-con-full e-flex e-con e-parent\" data-id=\"100f29a0\" data-element_type=\"container\" data-settings=\"{&quot;jet_parallax_layout_list&quot;:[]}\">\n\t\t<div class=\"elementor-element elementor-element-31c820d7 e-flex e-con-boxed e-con e-child\" data-id=\"31c820d7\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;,&quot;jet_parallax_layout_list&quot;:[]}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-402e7a88 e-con-full e-flex e-con e-child\" data-id=\"402e7a88\" data-element_type=\"container\" data-settings=\"{&quot;jet_parallax_layout_list&quot;:[]}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-295a4866 articletext elementor-widget elementor-widget-text-editor\" data-id=\"295a4866\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<h3><strong>De belangrijkste praktische voordelen zijn:<\/strong><\/h3><ul><li>Compact en licht ontwerp, waardoor minder laboratoriumruimte nodig is<\/li><li>Eenvoudigere installatie dan oudere fluorescentiedetectors<\/li><li>Upgrade-mogelijkheid voor bestaande systemen<\/li><\/ul><p>De detector sluit ook naadloos aan op bredere nutri\u00ebntenworkflows. SEAL gesegmenteerde flow analysatoren worden ingezet voor meerdere parameters, waaronder:<\/p><ul><li>Ammoniak<\/li><li>Nitraat + nitriet<\/li><li>Nitriet<\/li><li>Fosfaat<\/li><li>Silicaat<\/li><li>Totaal stikstof<\/li><li>Totaal fosfor<\/li><\/ul><p>Deze systemen ondersteunen ook inline monstervoorbereidingstechnieken zoals gasdiffusie, UV-digestie, dialyse en destillatie.<\/p><h3><strong>Detectie van ultralage ammoniak (2 nMol) in marien onderzoek <\/strong><\/h3><p>Voor mariene en milieutoepassingen is ultra lage ammoniakdetectie essentieel. De fluorometrische OPA methode maakt ammoniakdetectie in zeewater tot 2 nMol mogelijk, zonder de interferentie door brekingsindex effecten als gevolg van het zoutgehalte.<\/p><p>Dit maakt de methode uitermate geschikt voor oceanografisch onderzoek en nutri\u00ebntenstudies in zeewater, waar consistente prestaties bij wisselende zoutconcentraties vereist zijn.<\/p><p>SEAL Analytical gesegmenteerde flow analysatoren worden wereldwijd gebruikt door mariene onderzoeksinstellingen en oceanografische organisaties, waaronder: NOAA, Woods Hole Oceanographic Institution, Scripps Institution of Oceanography, NIOZ, IFREMER, JAMSTEC en de University of Hawaii.<\/p><p>De systemen zijn geschikt voor zowel laboratorium  als scheepsgebruik en ondersteunen toepassingen zoals:<\/p><ul><li>Kustmonitoring<\/li><li>Estuariumstudies<\/li><li>Aquacultuur analyse<\/li><li>Onderzoek naar mariene nutri\u00ebntencycli<\/li><li>Gebruik aan boord van onderzoeksschepen<\/li><\/ul><p>Stabiele LED lichtbronnen, trillingsbestendige detectors en automatische opstart  en stopfuncties maken lange, onbeheerde meetreeksen mogelijk, zelfs in veeleisende omgevingen.<\/p><p>\u00a0<\/p><h3><strong>Een praktische oplossing voor ultra-lage ammoniakanalyse<\/strong><\/h3><p>De nieuwe SEAL fluorometer biedt laboratoria een toegewijde oplossing voor ultra lage ammoniakanalyse, zonder de beperkingen die typisch zijn voor kleurmetrische zeewatermethoden of extern aangepaste fluorescentiedetectors.<\/p><p>Dankzij het compacte ontwerp, directe integratie met gesegmenteerde flow systemen, verminderde reagenscomplexiteit en verhoogde weerstand tegen matrix effecten is dit een praktische en robuuste oplossing voor milieu , oceanografische en waterkwaliteitslaboratoria.<\/p><p>Voor laboratoria die hun gevoeligheid en betrouwbaarheid bij ammoniakmetingen willen verbeteren, breidt deze fluorometer de mogelijkheden van bestaande gesegmenteerde flow platformen uit, met behoud van een naadloze workflow integratie.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-4ff2e961 e-con-full e-flex e-con e-parent\" data-id=\"4ff2e961\" data-element_type=\"container\" data-settings=\"{&quot;jet_parallax_layout_list&quot;:[]}\">\n\t\t<div class=\"elementor-element elementor-element-11c42407 e-flex e-con-boxed e-con e-child\" data-id=\"11c42407\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;,&quot;jet_parallax_layout_list&quot;:[]}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-77f7c60b e-con-full e-flex e-con e-child\" data-id=\"77f7c60b\" data-element_type=\"container\" data-settings=\"{&quot;jet_parallax_layout_list&quot;:[]}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-28fd2868 elementor-widget elementor-widget-heading\" data-id=\"28fd2868\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">FAQ<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-d129b6a e-con-full e-flex e-con e-child\" data-id=\"d129b6a\" data-element_type=\"container\" data-settings=\"{&quot;jet_parallax_layout_list&quot;:[]}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-59be1f12 elementor-widget elementor-widget-n-accordion\" data-id=\"59be1f12\" data-element_type=\"widget\" data-settings=\"{&quot;default_state&quot;:&quot;expanded&quot;,&quot;max_items_expended&quot;:&quot;one&quot;,&quot;n_accordion_animation_duration&quot;:{&quot;unit&quot;:&quot;ms&quot;,&quot;size&quot;:400,&quot;sizes&quot;:[]}}\" data-widget_type=\"nested-accordion.default\">\n\t\t\t\t\t\t\t<div class=\"e-n-accordion\" aria-label=\"Accordeon. Links openen met Enter of Spatie, sluiten met Escape en navigeren met Pijltjestoetsen\">\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-1500\" class=\"e-n-accordion-item\" open>\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"1\" tabindex=\"0\" aria-expanded=\"true\" aria-controls=\"e-n-accordion-item-1500\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Welke detectiemethode gebruikt de fluorometer? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-minus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h384c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-plus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H272V64c0-17.67-14.33-32-32-32h-32c-17.67 0-32 14.33-32 32v144H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h144v144c0 17.67 14.33 32 32 32h32c17.67 0 32-14.33 32-32V304h144c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-1500\" class=\"elementor-element elementor-element-4fa5e297 e-con-full e-flex e-con e-child\" data-id=\"4fa5e297\" data-element_type=\"container\" data-settings=\"{&quot;jet_parallax_layout_list&quot;:[]}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-255b943d elementor-widget elementor-widget-text-editor\" data-id=\"255b943d\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>De fluorometer maakt gebruik van de o\u2011ftaalaldehyde (OPA)\u2011fluorescentiemethode. Ammoniak reageert met OPA in aanwezigheid van een boraatbuffer en natriumsulfiet, waarbij een fluorescerende verbinding ontstaat die met zeer hoge gevoeligheid kan worden gemeten.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-1501\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"2\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-1501\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Waarom is ammoniakanalyse in zeewater een uitdaging? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-minus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h384c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-plus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H272V64c0-17.67-14.33-32-32-32h-32c-17.67 0-32 14.33-32 32v144H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h144v144c0 17.67 14.33 32 32 32h32c17.67 0 32-14.33 32-32V304h144c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-1501\" class=\"elementor-element elementor-element-592db755 e-con-full e-flex e-con e-child\" data-id=\"592db755\" data-element_type=\"container\" data-settings=\"{&quot;jet_parallax_layout_list&quot;:[]}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-2ae5da3e elementor-widget elementor-widget-text-editor\" data-id=\"2ae5da3e\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>Ammoniakanalyse in zeewater is uitdagend door de hoge en variabele zoutconcentratie, die verschillen in brekingsindex en matrix\u2011effecten veroorzaakt. Deze interfereren met traditionele kleurmetrische methoden, waardoor de nauwkeurigheid en betrouwbaarheid bij lage concentraties afnemen.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-1502\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"3\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-1502\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Hoe presteert de OPA\u2011fluorometrische methode beter dan de Berthelot\u2011kleurmethode? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-minus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h384c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-plus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H272V64c0-17.67-14.33-32-32-32h-32c-17.67 0-32 14.33-32 32v144H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h144v144c0 17.67 14.33 32 32 32h32c17.67 0 32-14.33 32-32V304h144c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-1502\" class=\"elementor-element elementor-element-102f0904 e-con-full e-flex e-con e-child\" data-id=\"102f0904\" data-element_type=\"container\" data-settings=\"{&quot;jet_parallax_layout_list&quot;:[]}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-4da83b7c elementor-widget elementor-widget-text-editor\" data-id=\"4da83b7c\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>In tegenstelling tot Berthelot\u2011 of fenolmethode\u2011kleurmetingen wordt de OPA\u2011fluorometrische methode niet be\u00efnvloed door brekingsindexverschillen als gevolg van zoutgehalte. Daardoor is zij veel betrouwbaarder voor zeewatermonsters en levert zij consistente prestaties bij uiteenlopende zoutconcentraties.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-1503\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"4\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-1503\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Is de fluorometer geschikt voor marien en scheepsgebruik? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-minus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h384c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-plus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H272V64c0-17.67-14.33-32-32-32h-32c-17.67 0-32 14.33-32 32v144H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h144v144c0 17.67 14.33 32 32 32h32c17.67 0 32-14.33 32-32V304h144c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-1503\" class=\"elementor-element elementor-element-35e1f8f e-con-full e-flex e-con e-child\" data-id=\"35e1f8f\" data-element_type=\"container\" data-settings=\"{&quot;jet_parallax_layout_list&quot;:[]}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-e4f6681 elementor-widget elementor-widget-text-editor\" data-id=\"e4f6681\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>Ja. De fluorometer en gesegmenteerde flow\u2011systemen beschikken over stabiele LED\u2011lichtbronnen, trillingsbestendige detectoren en geautomatiseerde opstart\u2011 en stopfuncties, waardoor ze geschikt zijn voor lange onbeheerde meetreeksen en gebruik aan boord van schepen.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-1504\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"5\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-1504\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Wat is de beste methode voor ultra\u2011lage ammoniakmetingen in zeewater? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-minus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h384c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-plus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H272V64c0-17.67-14.33-32-32-32h-32c-17.67 0-32 14.33-32 32v144H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h144v144c0 17.67 14.33 32 32 32h32c17.67 0 32-14.33 32-32V304h144c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-1504\" class=\"elementor-element elementor-element-846c933 e-con-full e-flex e-con e-child\" data-id=\"846c933\" data-element_type=\"container\" data-settings=\"{&quot;jet_parallax_layout_list&quot;:[]}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-828f627 elementor-widget elementor-widget-text-editor\" data-id=\"828f627\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>Voor ultra\u2011lage ammoniakbepaling in zeewater is de OPA\u2011fluorometrische methode binnen gesegmenteerde flow\u2011analyse bijzonder effectief. Deze biedt detectielimieten tot 2 nMol en elimineert zoutgerelateerde brekingsindex\u2011interferentie die vaak voorkomt bij kleurmetrische methoden.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-1505\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"6\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-1505\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Waarom heeft fluormetrische ammoniakanalyse de voorkeur in oceanografisch onderzoek? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-minus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h384c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-plus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H272V64c0-17.67-14.33-32-32-32h-32c-17.67 0-32 14.33-32 32v144H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h144v144c0 17.67 14.33 32 32 32h32c17.67 0 32-14.33 32-32V304h144c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-1505\" class=\"elementor-element elementor-element-a053c3a e-con-full e-flex e-con e-child\" data-id=\"a053c3a\" data-element_type=\"container\" data-settings=\"{&quot;jet_parallax_layout_list&quot;:[]}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-e4f1986 elementor-widget elementor-widget-text-editor\" data-id=\"e4f1986\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>Fluorometrische ammoniakanalyse geniet de voorkeur in oceanografisch onderzoek omdat zij betrouwbare detectie op nanomolniveau mogelijk maakt, nauwkeurig blijft bij vari\u00ebrende zoutgehalten en lange onbeheerde werking ondersteunt in zowel laboratorium\u2011 als mariene omgevingen.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-fce0125 elementor-widget elementor-widget-html\" data-id=\"fce0125\" data-element_type=\"widget\" data-widget_type=\"html.default\">\n\t\t\t\t\t<script type=\"application\/ld+json\">{\n    \"@context\": \"https:\\\/\\\/schema.org\",\n    \"@type\": \"FAQPage\",\n    \"mainEntity\": [\n        {\n            \"@type\": \"Question\",\n            \"name\": \"What detection method does the fluorometer use?\",\n            \"acceptedAnswer\": {\n                \"@type\": \"Answer\",\n                \"text\": \"The fluorometer uses the o\\u2011phthalaldehyde (OPA) fluorescence method. Ammonia reacts with OPA in the presence of borate buffer and sodium sulfite to form a fluorescent compound, which can be measured with extremely high sensitivity.\"\n            }\n        },\n        {\n            \"@type\": \"Question\",\n            \"name\": \"Why is ammonia analysis in seawater challenging?\",\n            \"acceptedAnswer\": {\n                \"@type\": \"Answer\",\n                \"text\": \"Ammonia analysis in seawater is challenging due to high and variable salinity, which causes refractive index differences and matrix effects. These issues interfere with traditional colorimetric methods, reducing accuracy and reliability at low concentration levels.\"\n            }\n        },\n        {\n            \"@type\": \"Question\",\n            \"name\": \"How does the OPA fluorometric method outperform the Berthelot colorimetric method?\",\n            \"acceptedAnswer\": {\n                \"@type\": \"Answer\",\n                \"text\": \"Unlike Berthelot or phenate colorimetric methods, the OPA fluorometric method is not affected by refractive index differences caused by salinity. This makes it far more reliable for seawater samples and allows consistent performance across varying salt concentrations.\"\n            }\n        },\n        {\n            \"@type\": \"Question\",\n            \"name\": \"Is the fluorometer suitable for marine and shipboard use?\",\n            \"acceptedAnswer\": {\n                \"@type\": \"Answer\",\n                \"text\": \"Yes. The fluorometer and segmented flow systems feature stable LED light sources, vibration-resistant detectors, and automated startup\\\/shutdown functions, making them suitable for long unattended runs and shipboard operation.\"\n            }\n        },\n        {\n            \"@type\": \"Question\",\n            \"name\": \"What is the best method for ultra-low ammonia measurement in seawater?\",\n            \"acceptedAnswer\": {\n                \"@type\": \"Answer\",\n                \"text\": \"For ultra-low ammonia measurement in seawater, the OPA fluorometric method used in segmented flow analysis is highly effective. It provides detection limits down to 2 nMol while eliminating salinity-related refractive index interference common in colorimetric methods.\"\n            }\n        },\n        {\n            \"@type\": \"Question\",\n            \"name\": \"Why is fluorometric ammonia analysis preferred for oceanographic research?\",\n            \"acceptedAnswer\": {\n                \"@type\": \"Answer\",\n                \"text\": \"Fluorometric ammonia analysis is preferred in oceanographic research because it enables reliable detection at nanomolar levels, maintains accuracy across varying salinities, and supports long unattended operation in laboratory and shipboard environments.\"\n            }\n        }\n    ]\n}<\/script>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2e32356 elementor-widget elementor-widget-html\" data-id=\"2e32356\" data-element_type=\"widget\" data-widget_type=\"html.default\">\n\t\t\t\t\t<script type=\"application\/ld+json\">{\n    \"@context\": \"https:\\\/\\\/schema.org\",\n    \"@type\": \"BlogPosting\",\n    \"mainEntityOfPage\": {\n        \"@type\": \"WebPage\",\n        \"@id\": \"https:\\\/\\\/scispx.com\\\/a-new-fluorometric-approach-for-ultra-low-ammonia-analysis\\\/\"\n    },\n    \"headline\": \"A new fluorometric approach for ultra-low ammonia analysis\",\n    \"description\": \"The new Analytical fluorometer is a very sensitive fluorimeter that can be added to the Flow systems of SEAL. It uses the OPA fluorescence method to detect ammonia in seawater down to 2 nMol, while eliminating salinity-related interference that affects traditional Berthelot colorimetric methods.\",\n    \"image\": \"https:\\\/\\\/scispx.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/LinkedIn-SciSPX-48.png\",\n    \"author\": {\n        \"@type\": \"Organization\",\n        \"name\": \"SciSPX\",\n        \"url\": \"https:\\\/\\\/scispx.com\\\/\"\n    },\n    \"publisher\": {\n        \"@type\": \"Organization\",\n        \"name\": \"SciSPX\",\n        \"logo\": {\n            \"@type\": \"ImageObject\",\n            \"url\": \"https:\\\/\\\/scispx.com\\\/wp-content\\\/uploads\\\/2025\\\/04\\\/SciSPX_RGB-Icon.png\"\n        }\n    },\n    \"datePublished\": \"2026-04-22\",\n    \"dateModified\": \"2026-04-23\"\n}<\/script>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Nieuwe Analytische fluorometer Zeer gevoelige fluorimeter die kan worden toegevoegd aan de stromingssystemen van SEA Neem contact op Snelle samenvatting Ontdek SEAL Analytical De nieuwe Analytische fluorometer is een zeer gevoelige fluorimeter die kan worden toegevoegd aan de stromingssystemen van SEA. Hij maakt gebruik van de OPA-fluorescentiemethode om ammoniak in zeewater te detecteren tot [...]...<\/p>","protected":false},"author":171,"featured_media":5097,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"_mo_disable_npp":"","footnotes":""},"class_list":["post-5094","page","type-page","status-publish","has-post-thumbnail","hentry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v25.5 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>A new fluorometric approach for ultra-low ammonia analysis<\/title>\n<meta name=\"description\" content=\"The new Analytical fluorometer is a very sensitive fluorimeter that can be added to the Flow systems of SEAL.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/scispx.com\/nl\/een-nieuwe-fluorometrische-benadering-voor-utlra-lage-ammoniakanalyse\/\" \/>\n<meta property=\"og:locale\" content=\"nl_NL\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"A new fluorometric approach for ultra-low ammonia analysis\" \/>\n<meta property=\"og:description\" content=\"The new Analytical fluorometer is a very sensitive fluorimeter that can be added to the Flow systems of SEAL.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/scispx.com\/nl\/een-nieuwe-fluorometrische-benadering-voor-utlra-lage-ammoniakanalyse\/\" \/>\n<meta property=\"og:site_name\" content=\"SciSPX Analysis simplified\" \/>\n<meta property=\"article:modified_time\" content=\"2026-04-23T07:36:50+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/scispx.com\/wp-content\/uploads\/2026\/04\/LinkedIn-SciSPX-48.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"630\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Geschatte leestijd\" \/>\n\t<meta name=\"twitter:data1\" content=\"6 minuten\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/scispx.com\/nl\/een-nieuwe-fluorometrische-benadering-voor-utlra-lage-ammoniakanalyse\/\",\"url\":\"https:\/\/scispx.com\/nl\/een-nieuwe-fluorometrische-benadering-voor-utlra-lage-ammoniakanalyse\/\",\"name\":\"A new fluorometric approach for ultra-low ammonia analysis\",\"isPartOf\":{\"@id\":\"https:\/\/scispx.com\/nl\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/scispx.com\/nl\/een-nieuwe-fluorometrische-benadering-voor-utlra-lage-ammoniakanalyse\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/scispx.com\/nl\/een-nieuwe-fluorometrische-benadering-voor-utlra-lage-ammoniakanalyse\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/scispx.com\/wp-content\/uploads\/2026\/04\/LinkedIn-SciSPX-48.png\",\"datePublished\":\"2026-04-22T14:22:21+00:00\",\"dateModified\":\"2026-04-23T07:36:50+00:00\",\"description\":\"The new Analytical fluorometer is a very sensitive fluorimeter that can be added to the Flow systems of SEAL.\",\"breadcrumb\":{\"@id\":\"https:\/\/scispx.com\/nl\/een-nieuwe-fluorometrische-benadering-voor-utlra-lage-ammoniakanalyse\/#breadcrumb\"},\"inLanguage\":\"nl-NL\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/scispx.com\/nl\/een-nieuwe-fluorometrische-benadering-voor-utlra-lage-ammoniakanalyse\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"nl-NL\",\"@id\":\"https:\/\/scispx.com\/nl\/een-nieuwe-fluorometrische-benadering-voor-utlra-lage-ammoniakanalyse\/#primaryimage\",\"url\":\"https:\/\/scispx.com\/wp-content\/uploads\/2026\/04\/LinkedIn-SciSPX-48.png\",\"contentUrl\":\"https:\/\/scispx.com\/wp-content\/uploads\/2026\/04\/LinkedIn-SciSPX-48.png\",\"width\":1200,\"height\":630,\"caption\":\"fluorometer\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/scispx.com\/nl\/een-nieuwe-fluorometrische-benadering-voor-utlra-lage-ammoniakanalyse\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/scispx.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"A new fluorometric approach for ultra-low ammonia analysis\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/scispx.com\/nl\/#website\",\"url\":\"https:\/\/scispx.com\/nl\/\",\"name\":\"SciSPX Analysis simplified\",\"description\":\"SciSPX Analysis simplified\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/scispx.com\/nl\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"nl-NL\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Een nieuwe fluormetrische aanpak voor ammoniakanalyse bij ultralaag ammoniakgehalte","description":"De nieuwe Analytical fluorometer is een zeer gevoelige fluorimeter die kan worden toegevoegd aan de Flow\u2011systemen van SEAL.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/scispx.com\/nl\/een-nieuwe-fluorometrische-benadering-voor-utlra-lage-ammoniakanalyse\/","og_locale":"nl_NL","og_type":"article","og_title":"A new fluorometric approach for ultra-low ammonia analysis","og_description":"The new Analytical fluorometer is a very sensitive fluorimeter that can be added to the Flow systems of SEAL.","og_url":"https:\/\/scispx.com\/nl\/een-nieuwe-fluorometrische-benadering-voor-utlra-lage-ammoniakanalyse\/","og_site_name":"SciSPX Analysis simplified","article_modified_time":"2026-04-23T07:36:50+00:00","og_image":[{"width":1200,"height":630,"url":"https:\/\/scispx.com\/wp-content\/uploads\/2026\/04\/LinkedIn-SciSPX-48.png","type":"image\/png"}],"twitter_card":"summary_large_image","twitter_misc":{"Geschatte leestijd":"6 minuten"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/scispx.com\/nl\/een-nieuwe-fluorometrische-benadering-voor-utlra-lage-ammoniakanalyse\/","url":"https:\/\/scispx.com\/nl\/een-nieuwe-fluorometrische-benadering-voor-utlra-lage-ammoniakanalyse\/","name":"Een nieuwe fluormetrische aanpak voor ammoniakanalyse bij ultralaag ammoniakgehalte","isPartOf":{"@id":"https:\/\/scispx.com\/nl\/#website"},"primaryImageOfPage":{"@id":"https:\/\/scispx.com\/nl\/een-nieuwe-fluorometrische-benadering-voor-utlra-lage-ammoniakanalyse\/#primaryimage"},"image":{"@id":"https:\/\/scispx.com\/nl\/een-nieuwe-fluorometrische-benadering-voor-utlra-lage-ammoniakanalyse\/#primaryimage"},"thumbnailUrl":"https:\/\/scispx.com\/wp-content\/uploads\/2026\/04\/LinkedIn-SciSPX-48.png","datePublished":"2026-04-22T14:22:21+00:00","dateModified":"2026-04-23T07:36:50+00:00","description":"De nieuwe Analytical fluorometer is een zeer gevoelige fluorimeter die kan worden toegevoegd aan de Flow\u2011systemen van SEAL.","breadcrumb":{"@id":"https:\/\/scispx.com\/nl\/een-nieuwe-fluorometrische-benadering-voor-utlra-lage-ammoniakanalyse\/#breadcrumb"},"inLanguage":"nl-NL","potentialAction":[{"@type":"ReadAction","target":["https:\/\/scispx.com\/nl\/een-nieuwe-fluorometrische-benadering-voor-utlra-lage-ammoniakanalyse\/"]}]},{"@type":"ImageObject","inLanguage":"nl-NL","@id":"https:\/\/scispx.com\/nl\/een-nieuwe-fluorometrische-benadering-voor-utlra-lage-ammoniakanalyse\/#primaryimage","url":"https:\/\/scispx.com\/wp-content\/uploads\/2026\/04\/LinkedIn-SciSPX-48.png","contentUrl":"https:\/\/scispx.com\/wp-content\/uploads\/2026\/04\/LinkedIn-SciSPX-48.png","width":1200,"height":630,"caption":"fluorometer"},{"@type":"BreadcrumbList","@id":"https:\/\/scispx.com\/nl\/een-nieuwe-fluorometrische-benadering-voor-utlra-lage-ammoniakanalyse\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/scispx.com\/"},{"@type":"ListItem","position":2,"name":"A new fluorometric approach for ultra-low ammonia analysis"}]},{"@type":"WebSite","@id":"https:\/\/scispx.com\/nl\/#website","url":"https:\/\/scispx.com\/nl\/","name":"SciSPX Analyse vereenvoudigd","description":"SciSPX Analyse vereenvoudigd","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/scispx.com\/nl\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"nl-NL"}]}},"_links":{"self":[{"href":"https:\/\/scispx.com\/nl\/wp-json\/wp\/v2\/pages\/5094","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/scispx.com\/nl\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/scispx.com\/nl\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/scispx.com\/nl\/wp-json\/wp\/v2\/users\/171"}],"replies":[{"embeddable":true,"href":"https:\/\/scispx.com\/nl\/wp-json\/wp\/v2\/comments?post=5094"}],"version-history":[{"count":0,"href":"https:\/\/scispx.com\/nl\/wp-json\/wp\/v2\/pages\/5094\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/scispx.com\/nl\/wp-json\/wp\/v2\/media\/5097"}],"wp:attachment":[{"href":"https:\/\/scispx.com\/nl\/wp-json\/wp\/v2\/media?parent=5094"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}