{"id":5089,"date":"2026-04-22T10:03:00","date_gmt":"2026-04-22T08:03:00","guid":{"rendered":"https:\/\/scispx.com\/?post_type=instruments&#038;p=5089"},"modified":"2026-04-22T10:03:36","modified_gmt":"2026-04-22T08:03:36","slug":"iso-dual-inlet-systeem-voor-irms","status":"publish","type":"instruments","link":"https:\/\/scispx.com\/nl\/instruments\/iso-dual-inlet-systeem-voor-irms\/","title":{"rendered":"Iso DUAL INLET"},"content":{"rendered":"<h2 data-start=\"266\" data-end=\"446\">Hoog\u2011precies dual\u2011inlet\u2011systeem voor IRMS<\/h2>\n<p data-start=\"266\" data-end=\"446\">Iso DUAL INLET van Elementar is een hoog\u2011precies dual\u2011inlet\u2011systeem voor isotopenverhouding\u2011massaspectrometrie (DI\u2011IRMS), ideaal voor de analyse van zuivere gassen, carbonaatmaterialen en watermonsters.<\/p>\n<p data-start=\"448\" data-end=\"821\">Dual\u2011inlet\u2011technologie wordt algemeen beschouwd als de meest precieze, nauwkeurige en gevoelige methode voor isotopenanalyse van deze monstertypes. Omdat instrumentele precisie direct de datakwaliteit be\u00efnvloedt, speelt het systeem een sleutelrol in toepassingen zoals paleoklimaatonderzoek, waar uiterst nauwkeurige isotopenmetingen essentieel zijn voor betrouwbare klimaatreconstructies.<\/p>\n<p data-start=\"5899\" data-end=\"5939\"><strong>Iso DUAL INLET werkt met:<\/strong><\/p>\n<ul data-start=\"5940\" data-end=\"6144\">\n<li data-section-id=\"133fe40\" data-start=\"5940\" data-end=\"6012\"><a href=\"https:\/\/scispx.com\/nl\/instruments\/isoprime-precision-mass-spectrometer\/\" target=\"_blank\" rel=\"noopener\">isoprime precisION<\/a> IRMS voor \u03b4\u00b9\u00b3C, \u03b4\u00b9\u2075N, \u03b4\u00b3\u2074S, \u03b4\u00b9\u2078O, en \u03b4\u00b2H analyse<\/li>\n<li data-section-id=\"cjf1c4\" data-start=\"6013\" data-end=\"6079\">lyticOS\u00ae Software Suite voor volledige automatisering en methode\u2011aansturing<\/li>\n<li data-section-id=\"uu2n3\" data-start=\"6080\" data-end=\"6144\">ArDB cloudoplossingen voor databeheer en kwaliteitscontrole<\/li>\n<\/ul>\n<h3 data-start=\"448\" data-end=\"821\"><strong>Waarom dual\u2011inlet\u2011technologie gebruiken?\u00a0<\/strong><\/h3>\n<p data-start=\"863\" data-end=\"1057\">Dual\u2011inlet\u2011systemen maken een directe vergelijking mogelijk tussen monstergas en referentiegas onder identieke omstandigheden. Dit minimaliseert analytische bias en garandeert de hoogst mogelijke meetprecisie.<\/p>\n<p data-start=\"1059\" data-end=\"1366\">Iso DUAL INLET gebruikt vacu\u00fcmtechnologie om monster\u2011 en referentiegassen te conditioneren en op elkaar af te stemmen v\u00f3\u00f3r introductie in het IRMS. Beide gassen volgen identieke trajecten en worden afwisselend in de ionenbron gebracht. Dit maakt herhaalde metingen van hetzelfde monster mogelijk en vergroot de statistische betrouwbaarheid.<\/p>\n<h3 data-section-id=\"99wzsm\" data-start=\"1373\" data-end=\"1423\"><strong>Wat zijn de belangrijkste voordelen van iso DUAL INLET?<\/strong><\/h3>\n<p data-start=\"1425\" data-end=\"1510\">Het systeem is ideaal om analytische prestaties te combineren met operationele effici\u00ebntie:<\/p>\n<ul data-start=\"1512\" data-end=\"1836\">\n<li data-section-id=\"1sxuscc\" data-start=\"1512\" data-end=\"1606\">Hoge gevoeligheid voor zowel grote als zeer kleine monstervolumes, inclusief kleine CO\u2082-monsters<\/li>\n<li data-section-id=\"t944n2\" data-start=\"1607\" data-end=\"1697\">Zeer nauwkeurige metingen, waaronder toonaangevende prestaties voor \u03b4\u00b9\u2078O\u2011analyse van water<\/li>\n<li data-section-id=\"16r5es6\" data-start=\"1698\" data-end=\"1774\">Compact benchtop\u2011ontwerp met ge\u00efntegreerde elektronica en vacu\u00fcmsysteem<\/li>\n<li data-section-id=\"lv3q14\" data-start=\"1775\" data-end=\"1836\">Hoge mate van automatisering en lage onderhoudsbehoefte<\/li>\n<\/ul>\n<h3 data-section-id=\"y2lmj\" data-start=\"1843\" data-end=\"1900\"><strong>Hoe gaat iso DUAL INLET om met verschillende monstergroottes?<\/strong><\/h3>\n<p data-start=\"1902\" data-end=\"2016\">Het systeem beschikt over een breed dynamisch bereik, waardoor zowel zeer kleine als grote monsters zonder handmatige afstelling kunnen worden geanalyseerd.<\/p>\n<p data-start=\"2018\" data-end=\"2043\"><strong>Dit wordt mogelijk gemaakt door:<\/strong><\/p>\n<ul data-start=\"2044\" data-end=\"2211\">\n<li data-section-id=\"1hvms83\" data-start=\"2044\" data-end=\"2135\">Twee softwaregestuurde hogedrukbalgen met stappenmotor<\/li>\n<li data-section-id=\"18d6wa0\" data-start=\"2136\" data-end=\"2211\">Een gepatenteerde automatische micro\u2011volume cold finger voor zeer kleine monsters<\/li>\n<\/ul>\n<p data-start=\"2213\" data-end=\"2317\">Hierdoor kunnen zelfs minimale monstervolumes met hoge precisie en nauwkeurigheid worden geanalyseerd.<\/p>\n<h3 data-section-id=\"nzjbt\" data-start=\"2324\" data-end=\"2358\"><strong>Hoe wordt hoge precisie bereikt?<\/strong><\/h3>\n<p data-start=\"2360\" data-end=\"2459\">Nauwkeurige gasbehandeling en een zorgvuldig instrumentontwerp zorgen voor uitzonderlijke analytische precisie.<\/p>\n<p data-start=\"2461\" data-end=\"2482\"><strong>De belangrijkste elementen zijn:<\/strong><\/p>\n<ul data-start=\"2483\" data-end=\"2731\">\n<li data-section-id=\"phfje1\" data-start=\"2483\" data-end=\"2564\">Identieke behandeling van monster- en referentiegassen via parallelle stromingstrajecten<\/li>\n<li data-section-id=\"r3v2zd\" data-start=\"2565\" data-end=\"2642\">14 ultralage\u2011dode\u2011volume ventielen uit hoogzuiver roestvrij staal<\/li>\n<li data-section-id=\"1ekxx5c\" data-start=\"2643\" data-end=\"2731\">Een turbomoleculaire pomp voor het omschakelventiel om geheugeneffecten te voorkomen<\/li>\n<\/ul>\n<p data-start=\"2733\" data-end=\"2862\">Deze configuratie maakt uiterst nauwkeurige isotopenverhoudingmetingen mogelijk, inclusief hoog\u2011precisie \u03b4\u00b9\u2078O\u2011analyse van watermonsters.<\/p>\n<h3 data-section-id=\"hu6tna\" data-start=\"2869\" data-end=\"2910\"><strong>Hoe verbetert automatisering het gebruiksgemak?<\/strong><\/h3>\n<p data-start=\"2912\" data-end=\"3037\">Het systeem wordt volledig aangestuurd via de lyticOS\u00ae Software Suite, waardoor handmatige tussenkomst tot een minimum wordt beperkt.<\/p>\n<p data-start=\"3039\" data-end=\"3059\"><strong>Automatisering omvat:<\/strong><\/p>\n<ul data-start=\"3060\" data-end=\"3339\">\n<li data-section-id=\"eoodhq\" data-start=\"3060\" data-end=\"3110\">Automatische gasexpansie en intensiteitsmatching<\/li>\n<li data-section-id=\"2ic8hc\" data-start=\"3111\" data-end=\"3167\">Controle over snijroutines zonder voorprogrammering<\/li>\n<li data-section-id=\"1sqh87y\" data-start=\"3168\" data-end=\"3251\">Lange onbeheerde meetreeksen, ondersteund door referentiegasbalgen van 100\u202fml<\/li>\n<li data-section-id=\"1lbmgxl\" data-start=\"3252\" data-end=\"3339\">Minimaal onderhoud dankzij duurzame ventielcomponenten, ontworpen voor miljoenen cycli<\/li>\n<\/ul>\n<p data-start=\"3341\" data-end=\"3411\">Dit resulteert in een hoge uptime van het systeem en effici\u00ebnte laboratoriumworkflows.<\/p>\n<h3 data-section-id=\"1g87iek\" data-start=\"3418\" data-end=\"3461\"><strong>Hoe ziet de technische opstelling eruit?<\/strong><\/h3>\n<p data-start=\"3463\" data-end=\"3559\">Iso DUAL INLET gebruikt een vacu\u00fcmgebaseerd gashandlingsysteem voor monster\u00advoorbereiding.<\/p>\n<p data-start=\"3561\" data-end=\"3578\"><strong>Procesoverzicht:<\/strong><\/p>\n<ul data-start=\"3579\" data-end=\"3880\">\n<li data-section-id=\"9j622z\" data-start=\"3579\" data-end=\"3662\">Turbomoleculaire pompen isoleren en expanderen de monster- en referentiegassen<\/li>\n<li data-section-id=\"1u6j141\" data-start=\"3663\" data-end=\"3717\">Gassen worden intensiteitsgematcht via variabele balgen<\/li>\n<li data-section-id=\"323f56\" data-start=\"3718\" data-end=\"3793\">Een omschakelventiel wisselt de gasstromen in de ionenbron van het IRMS<\/li>\n<li data-section-id=\"1mpqco\" data-start=\"3794\" data-end=\"3880\">Meerdere metingen per monster verbeteren de statistische nauwkeurigheid<\/li>\n<\/ul>\n<p data-start=\"3882\" data-end=\"3957\">Het systeem voorkomt isotopische fractionering tijdens de behandeling van het gas.<\/p>\n<h3 data-section-id=\"exltym\" data-start=\"3964\" data-end=\"4017\"><strong>Welke systemen kunnen worden gecombineerd met iso DUAL INLET?<\/strong><\/h3>\n<div>\n<table>\n<tbody>\n<tr>\n<th scope=\"row\"><strong>Gecombineerde carbonaat- en wateranalyse<\/strong><\/th>\n<td><strong>iso MULTI PREP<\/strong><\/td>\n<td>E\u00e9n systeem voor carbonaat- en watermonsters<br \/>\nSnel schakelen tussen modi door naaldconfiguratie te veranderen<\/td>\n<td>Moduswissel in enkele minuten<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\"><strong>Zeer nauwkeurige wateranalyse<\/strong><\/th>\n<td><strong>iso AQUA PREP<\/strong><\/td>\n<td>\u03b4\u00b9\u2078O wateranalyse met evenwichtstechniek<br \/>\nHoge stabiliteit zonder meetbare drift<\/td>\n<td>Precisie &lt; 0,05 \u2030 (1\u03c3, n = 10)<br \/>\nTot 180 monsters per reeks<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\"><strong>Zeer gevoelige carbonaatanalyse<\/strong><\/th>\n<td><strong>iso CARB PREP<\/strong><\/td>\n<td>Geautomatiseerde carbonaatanalyse tot 20 \u00b5g<br \/>\nDual\u2011core naald, direct aangedreven zuurpomp, LN\u2082\u2011cold finger voor CO\u2082\u2011trapping<\/td>\n<td>Tot 180 monsters in verwarmde tray<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\"><strong>Geautomatiseerde analyse van zuivere gassen<\/strong><\/th>\n<td><strong>iso MANIFOLD<\/strong><\/td>\n<td>Geautomatiseerde analyse van afgesloten gasmonsters<br \/>\nOndersteunt ventielafgesloten buizen en breekglasampules<\/td>\n<td>Tot 50 ventielafgesloten buizen<br \/>\nTot 20 breekglasampules<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3 data-section-id=\"rnexpj\" data-start=\"5207\" data-end=\"5248\"><strong>Analytische opties\u00a0<\/strong><\/h3>\n<p data-start=\"5250\" data-end=\"5274\">Iso DUAL INLET ondersteunt:<\/p>\n<ul data-start=\"5275\" data-end=\"5520\">\n<li data-section-id=\"1btu7bh\" data-start=\"5275\" data-end=\"5330\">Analyse van zuivere gassen zoals CO\u2082, H\u2082, SO\u2082 en O\u2082<\/li>\n<li data-section-id=\"1s8fngs\" data-start=\"5331\" data-end=\"5391\">Gebruik als continuous\u2011flow monitoring gas\u2011injectiesysteem<\/li>\n<li data-section-id=\"13mu4gz\" data-start=\"5392\" data-end=\"5458\">Veilige omgang met toxische gassen door minimale blootstelling<\/li>\n<li data-section-id=\"14ts4iq\" data-start=\"5459\" data-end=\"5520\">Optionele IRMS\u2011upgrades voor clumped isotope\u2011analyse (\u039447)<\/li>\n<\/ul>\n<h3 data-section-id=\"1swmedy\" data-start=\"5527\" data-end=\"5564\"><strong>Monstertypes\u00a0<\/strong><\/h3>\n<p data-start=\"5566\" data-end=\"5643\">Afhankelijk van de configuratie ondersteunt het systeem:<\/p>\n<ul data-start=\"5645\" data-end=\"5858\">\n<li data-section-id=\"1ktl8f7\" data-start=\"5645\" data-end=\"5678\">Zuivere gassen (CO\u2082, O\u2082, H\u2082, SO\u2082)<\/li>\n<li data-section-id=\"19rl1v7\" data-start=\"5679\" data-end=\"5735\">Grondwater, ijskernen en biologische watermonsters<\/li>\n<li data-section-id=\"1e2zm5p\" data-start=\"5736\" data-end=\"5784\">Carbonaatmineralen en gefossiliseerde carbonaten<\/li>\n<li data-section-id=\"1qsypjs\" data-start=\"5785\" data-end=\"5858\">Gecombineerde carbonaat\u2011 en wateranalyse via multi\u2011prep\u2011configuraties<\/li>\n<\/ul>\n<\/div>\n<p><script type=\"application\/ld+json\">{\n    \"@context\": \"https:\\\/\\\/schema.org\",\n    \"@type\": \"FAQPage\",\n    \"mainEntity\": [\n        {\n            \"@type\": \"Question\",\n            \"name\": \"Why is dual inlet technology considered the gold standard for IRMS?\",\n            \"acceptedAnswer\": {\n                \"@type\": \"Answer\",\n                \"text\": \"Dual inlet technology allows direct comparison between sample gas and reference gas under identical instrumental conditions. This minimizes analytical bias, maximizes precision, and enables repeated measurements of the same sample for strong statistical confidence, making it the most accurate approach for selected isotope applications.\"\n            }\n        },\n        {\n            \"@type\": \"Question\",\n            \"name\": \"Why is Iso DUAL INLET important for paleoclimate research?\",\n            \"acceptedAnswer\": {\n                \"@type\": \"Answer\",\n                \"text\": \"Paleoclimate reconstructions depend on extremely precise isotope measurements, particularly of oxygen and carbon isotopes. Because Iso DUAL INLET provides very high instrumental precision, it supports reliable interpretation of climate signals preserved in carbonates, water, and ice cores.\"\n            }\n        },\n        {\n            \"@type\": \"Question\",\n            \"name\": \"How does Iso DUAL INLET handle very small sample sizes?\",\n            \"acceptedAnswer\": {\n                \"@type\": \"Answer\",\n                \"text\": \"The system offers a wide dynamic range and can analyze both very small and large samples without manual adjustment. This is achieved through software\\u2011controlled high\\u2011compression bellows and a patented micro\\u2011volume automatic cold finger designed for minimal sample volumes.\"\n            }\n        },\n        {\n            \"@type\": \"Question\",\n            \"name\": \"How does Iso DUAL INLET avoid isotopic fractionation?\",\n            \"acceptedAnswer\": {\n                \"@type\": \"Answer\",\n                \"text\": \"The vacuum\\u2011based gas handling system ensures that sample and reference gases are expanded and transferred under identical conditions, preventing fractionation during preparation and measurement.\"\n            }\n        },\n        {\n            \"@type\": \"Question\",\n            \"name\": \"What makes Iso DUAL INLET suitable for handling toxic gases?\",\n            \"acceptedAnswer\": {\n                \"@type\": \"Answer\",\n                \"text\": \"The system minimizes laboratory exposure by using closed vacuum handling and automated gas manipulation, allowing safe isotope analysis of toxic or hazardous gases.\"\n            }\n        },\n        {\n            \"@type\": \"Question\",\n            \"name\": \"Why is Iso DUAL INLET well suited for high\\u2011precision water isotope analysis?\",\n            \"acceptedAnswer\": {\n                \"@type\": \"Answer\",\n                \"text\": \"The system provides leading performance for \\u03b4\\u00b9\\u2078O analysis of water by maintaining stable gas handling conditions, eliminating fractionation, and enabling repeated measurements with very low measurement uncertainty.\"\n            }\n        }\n    ]\n}<\/script><\/p>\n<p><script type=\"application\/ld+json\">{\n    \"@context\": \"https:\\\/\\\/schema.org\\\/\",\n    \"@type\": \"Product\",\n    \"name\": \"Iso DUAL INLET\",\n    \"image\": \"https:\\\/\\\/scispx.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/iso-flow-dual.webp\",\n    \"description\": \"Iso DUAL INLET by Elementar is a high-precision dual inlet system for isotope ratio mass spectrometry (DI-IRMS), ideal for the analysis of pure gases, carbonate materials, and water samples.\",\n    \"brand\": {\n        \"@type\": \"Brand\",\n        \"name\": \"Elementar\"\n    },\n    \"offers\": {\n        \"@type\": \"Offer\",\n        \"url\": \"https:\\\/\\\/scispx.com\\\/instruments\\\/iso-dual-inlet-system-for-irms\\\/\",\n        \"priceCurrency\": \"EUR\",\n        \"price\": \"0\",\n        \"availability\": \"https:\\\/\\\/schema.org\\\/InStock\",\n        \"seller\": {\n            \"@type\": \"Organization\",\n            \"name\": \"SciSPX\",\n            \"url\": \"https:\\\/\\\/scispx.com\",\n            \"logo\": \"https:\\\/\\\/scispx.com\\\/wp-content\\\/uploads\\\/2025\\\/04\\\/SciSPX_RGB-Icon.png\",\n            \"areaServed\": [\n                {\n                    \"@type\": \"Country\",\n                    \"name\": \"Belgium\"\n                },\n                {\n                    \"@type\": \"Country\",\n                    \"name\": \"Netherlands\"\n                },\n                {\n                    \"@type\": \"Country\",\n                    \"name\": \"Luxembourg\"\n                }\n            ]\n        }\n    }\n}<\/script><\/p>","protected":false},"excerpt":{"rendered":"<p>Hoog\u2011precies dual\u2011inlet\u2011systeem voor isotopenverhouding\u2011massaspectrometrie<\/p>","protected":false},"featured_media":5090,"template":"","brands":[133],"applications":[215,245,231,449],"markets":[18,46],"class_list":["post-5089","instruments","type-instruments","status-publish","has-post-thumbnail","hentry","brands-elementar","applications-analysis","applications-chons","applications-elemental-analysis","applications-isotope-analyzers","markets-agriculture","markets-soil-and-water-conservation"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v25.5 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Iso DUAL INLET for IRMS | SciSPX Analysis simplified<\/title>\n<meta name=\"description\" content=\"Dual inlet system for isotope ratio mass spectrometry, ideal for the analysis of pure gases, carbonate materials, and water samples\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/scispx.com\/nl\/instruments\/iso-dual-inlet-systeem-voor-irms\/\" \/>\n<meta property=\"og:locale\" content=\"nl_NL\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Iso DUAL INLET for IRMS | SciSPX Analysis simplified\" \/>\n<meta property=\"og:description\" content=\"Dual inlet system for isotope ratio mass spectrometry, ideal for the analysis of pure gases, carbonate materials, and water samples\" \/>\n<meta property=\"og:url\" content=\"https:\/\/scispx.com\/nl\/instruments\/iso-dual-inlet-systeem-voor-irms\/\" \/>\n<meta property=\"og:site_name\" content=\"SciSPX Analysis simplified\" \/>\n<meta property=\"article:modified_time\" content=\"2026-04-22T08:03:36+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/scispx.com\/wp-content\/uploads\/2026\/04\/iso-flow-dual.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"1080\" \/>\n\t<meta property=\"og:image:height\" content=\"1080\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Geschatte leestijd\" \/>\n\t<meta name=\"twitter:data1\" content=\"4 minuten\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/scispx.com\/nl\/instruments\/iso-dual-inlet-systeem-voor-irms\/\",\"url\":\"https:\/\/scispx.com\/nl\/instruments\/iso-dual-inlet-systeem-voor-irms\/\",\"name\":\"Iso DUAL INLET for IRMS | SciSPX Analysis simplified\",\"isPartOf\":{\"@id\":\"https:\/\/scispx.com\/nl\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/scispx.com\/nl\/instruments\/iso-dual-inlet-systeem-voor-irms\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/scispx.com\/nl\/instruments\/iso-dual-inlet-systeem-voor-irms\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/scispx.com\/wp-content\/uploads\/2026\/04\/iso-flow-dual.webp\",\"datePublished\":\"2026-04-22T08:03:00+00:00\",\"dateModified\":\"2026-04-22T08:03:36+00:00\",\"description\":\"Dual inlet system for isotope ratio mass spectrometry, ideal for the analysis of pure gases, carbonate materials, and water samples\",\"breadcrumb\":{\"@id\":\"https:\/\/scispx.com\/nl\/instruments\/iso-dual-inlet-systeem-voor-irms\/#breadcrumb\"},\"inLanguage\":\"nl-NL\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/scispx.com\/nl\/instruments\/iso-dual-inlet-systeem-voor-irms\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"nl-NL\",\"@id\":\"https:\/\/scispx.com\/nl\/instruments\/iso-dual-inlet-systeem-voor-irms\/#primaryimage\",\"url\":\"https:\/\/scispx.com\/wp-content\/uploads\/2026\/04\/iso-flow-dual.webp\",\"contentUrl\":\"https:\/\/scispx.com\/wp-content\/uploads\/2026\/04\/iso-flow-dual.webp\",\"width\":1080,\"height\":1080,\"caption\":\"High-precision dual inlet system for IRMS\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/scispx.com\/nl\/instruments\/iso-dual-inlet-systeem-voor-irms\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/scispx.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Instruments\",\"item\":\"https:\/\/scispx.com\/instruments\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Iso DUAL INLET\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/scispx.com\/nl\/#website\",\"url\":\"https:\/\/scispx.com\/nl\/\",\"name\":\"SciSPX Analysis simplified\",\"description\":\"SciSPX Analysis simplified\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/scispx.com\/nl\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"nl-NL\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Iso DUAL INLET voor IRMS | SciSPX Analyse vereenvoudigd","description":"Dual\u2011inlet\u2011systeem voor isotopenverhouding\u2011massaspectrometrie, ideaal voor de analyse van zuivere gassen, carbonaatmaterialen en watermonsters.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/scispx.com\/nl\/instruments\/iso-dual-inlet-systeem-voor-irms\/","og_locale":"nl_NL","og_type":"article","og_title":"Iso DUAL INLET for IRMS | SciSPX Analysis simplified","og_description":"Dual inlet system for isotope ratio mass spectrometry, ideal for the analysis of pure gases, carbonate materials, and water samples","og_url":"https:\/\/scispx.com\/nl\/instruments\/iso-dual-inlet-systeem-voor-irms\/","og_site_name":"SciSPX Analysis simplified","article_modified_time":"2026-04-22T08:03:36+00:00","og_image":[{"width":1080,"height":1080,"url":"https:\/\/scispx.com\/wp-content\/uploads\/2026\/04\/iso-flow-dual.webp","type":"image\/webp"}],"twitter_card":"summary_large_image","twitter_misc":{"Geschatte leestijd":"4 minuten"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/scispx.com\/nl\/instruments\/iso-dual-inlet-systeem-voor-irms\/","url":"https:\/\/scispx.com\/nl\/instruments\/iso-dual-inlet-systeem-voor-irms\/","name":"Iso DUAL INLET voor IRMS | SciSPX Analyse vereenvoudigd","isPartOf":{"@id":"https:\/\/scispx.com\/nl\/#website"},"primaryImageOfPage":{"@id":"https:\/\/scispx.com\/nl\/instruments\/iso-dual-inlet-systeem-voor-irms\/#primaryimage"},"image":{"@id":"https:\/\/scispx.com\/nl\/instruments\/iso-dual-inlet-systeem-voor-irms\/#primaryimage"},"thumbnailUrl":"https:\/\/scispx.com\/wp-content\/uploads\/2026\/04\/iso-flow-dual.webp","datePublished":"2026-04-22T08:03:00+00:00","dateModified":"2026-04-22T08:03:36+00:00","description":"Dual\u2011inlet\u2011systeem voor isotopenverhouding\u2011massaspectrometrie, ideaal voor de analyse van zuivere gassen, carbonaatmaterialen en watermonsters.","breadcrumb":{"@id":"https:\/\/scispx.com\/nl\/instruments\/iso-dual-inlet-systeem-voor-irms\/#breadcrumb"},"inLanguage":"nl-NL","potentialAction":[{"@type":"ReadAction","target":["https:\/\/scispx.com\/nl\/instruments\/iso-dual-inlet-systeem-voor-irms\/"]}]},{"@type":"ImageObject","inLanguage":"nl-NL","@id":"https:\/\/scispx.com\/nl\/instruments\/iso-dual-inlet-systeem-voor-irms\/#primaryimage","url":"https:\/\/scispx.com\/wp-content\/uploads\/2026\/04\/iso-flow-dual.webp","contentUrl":"https:\/\/scispx.com\/wp-content\/uploads\/2026\/04\/iso-flow-dual.webp","width":1080,"height":1080,"caption":"High-precision dual inlet system for IRMS"},{"@type":"BreadcrumbList","@id":"https:\/\/scispx.com\/nl\/instruments\/iso-dual-inlet-systeem-voor-irms\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/scispx.com\/"},{"@type":"ListItem","position":2,"name":"Instruments","item":"https:\/\/scispx.com\/instruments\/"},{"@type":"ListItem","position":3,"name":"Iso DUAL INLET"}]},{"@type":"WebSite","@id":"https:\/\/scispx.com\/nl\/#website","url":"https:\/\/scispx.com\/nl\/","name":"SciSPX Analyse vereenvoudigd","description":"SciSPX Analyse vereenvoudigd","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/scispx.com\/nl\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"nl-NL"}]}},"_links":{"self":[{"href":"https:\/\/scispx.com\/nl\/wp-json\/wp\/v2\/instruments\/5089","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/scispx.com\/nl\/wp-json\/wp\/v2\/instruments"}],"about":[{"href":"https:\/\/scispx.com\/nl\/wp-json\/wp\/v2\/types\/instruments"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/scispx.com\/nl\/wp-json\/wp\/v2\/media\/5090"}],"wp:attachment":[{"href":"https:\/\/scispx.com\/nl\/wp-json\/wp\/v2\/media?parent=5089"}],"wp:term":[{"taxonomy":"brands","embeddable":true,"href":"https:\/\/scispx.com\/nl\/wp-json\/wp\/v2\/brands?post=5089"},{"taxonomy":"applications","embeddable":true,"href":"https:\/\/scispx.com\/nl\/wp-json\/wp\/v2\/applications?post=5089"},{"taxonomy":"markets","embeddable":true,"href":"https:\/\/scispx.com\/nl\/wp-json\/wp\/v2\/markets?post=5089"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}