{"id":5065,"date":"2026-04-16T10:52:32","date_gmt":"2026-04-16T08:52:32","guid":{"rendered":"https:\/\/scispx.com\/?post_type=instruments&#038;p=5065"},"modified":"2026-10-12T09:24:49","modified_gmt":"2026-10-12T07:24:49","slug":"gc5-gc-irms-system","status":"publish","type":"instruments","link":"https:\/\/scispx.com\/nl\/instruments\/gc5-gc-irms-system\/","title":{"rendered":"GC5"},"content":{"rendered":"<header class=\"headerlayout--h1\">\n<h2 class=\"\">Het GC-IRMS-systeem met de hoogste gevoeligheid<\/h2>\n<h3><strong>Wat is de GC5?<\/strong><\/h3>\n<\/header>\n<p data-start=\"179\" data-end=\"473\">De GC5 is een <strong>op gaschromatografie gebaseerd isotopenverhouding\u2011massaspectrometriesysteem (GC\u2011IRMS)<\/strong> voor stofspecifieke isotopenanalyse met zeer hoge gevoeligheid. Het systeem is ideaal voor geavanceerde toepassingen in biogeochemisch en forensisch onderzoek, waar gedetailleerd inzicht op moleculair niveau vereist is.<\/p>\n<p data-start=\"475\" data-end=\"766\">Door hoogwaardige gaschromatografie te combineren met isotopenverhouding\u2011massaspectrometrie, maakt het systeem een zeer nauwkeurige analyse van individuele verbindingen mogelijk, zelfs bij zeer lage concentraties. Het levert gevoeligheid op picomolniveau, terwijl de chromatografische integriteit behouden blijft tijdens de omzetting van verbindingen.<\/p>\n<h3 data-section-id=\"1ip9ohx\" data-start=\"773\" data-end=\"828\"><strong>Waarom is stofspecifieke isotopenanalyse belangrijk?<\/strong><\/h3>\n<p data-start=\"830\" data-end=\"1096\">Stofspecifieke isotopenanalyse stelt onderzoekers in staat de oorsprong, transformatie en reactiepaden van individuele verbindingen binnen complexe mengsels te bestuderen. Hierdoor is het een sleuteltechniek binnen onder andere geochemie, milieuwetenschappen en forensische analyse.<\/p>\n<p data-start=\"1098\" data-end=\"1205\">De GC5 is ontwikkeld om deze toepassingen te ondersteunen met hoge gevoeligheid en flexibele configuratiemogelijkheden.<\/p>\n<h3 data-section-id=\"o54pku\" data-start=\"1212\" data-end=\"1251\"><strong>Wat maakt de GC5 uiterst gevoelig?<\/strong><\/h3>\n<p data-start=\"1253\" data-end=\"1349\">Het systeem is ontworpen om zeer lage detectielimieten te bereiken zonder verlies aan piekkwaliteit.<\/p>\n<p data-start=\"1351\" data-end=\"1383\"><strong>Belangrijkste prestatiekenmerken:<\/strong><\/p>\n<ul data-start=\"1384\" data-end=\"1601\">\n<li data-section-id=\"1gn1f2n\" data-start=\"1384\" data-end=\"1424\">Detectiegevoeligheid op picomoolniveau<\/li>\n<li data-section-id=\"19xqpva\" data-start=\"1425\" data-end=\"1480\">Micro\u2011volume GC\u2011reactorbuisjes zonder dood volume<\/li>\n<li data-section-id=\"1fz60as\" data-start=\"1481\" data-end=\"1545\">Behoud van chromatografische piekvorm tijdens verbranding<\/li>\n<li data-section-id=\"b4ttzt\" data-start=\"1546\" data-end=\"1601\">Hoge signaalintegriteit voor analyten met lage concentraties<\/li>\n<\/ul>\n<p data-start=\"1603\" data-end=\"1730\">Het microreactorontwerp zorgt voor stabiele oxidatieprestaties over lange tijd, wat bijdraagt aan consistente analytische resultaten.<\/p>\n<h3 data-section-id=\"mge5lo\" data-start=\"1737\" data-end=\"1788\"><strong>Hoe wordt betrouwbare en stabiele analyse gegarandeerd?<\/strong><\/h3>\n<p data-start=\"1790\" data-end=\"1974\">De GC5 gebruikt continue zuurstoftoevoer in de oven om optimale oxidatiecondities te handhaven. Dit verbetert de stabiliteit op lange termijn en garandeert consistente analytische prestaties.<\/p>\n<p data-start=\"1976\" data-end=\"2027\"><strong>Aanvullende kenmerken die de betrouwbaarheid ondersteunen:<\/strong><\/p>\n<ul data-start=\"2028\" data-end=\"2285\">\n<li data-section-id=\"1bxhv6n\" data-start=\"2028\" data-end=\"2085\">Continue O\u2082-dosering voor stabiele verbranding<\/li>\n<li data-section-id=\"4kzc38\" data-start=\"2086\" data-end=\"2165\">Automatische O\u2082\u2011herlading voor \u03b4\u00b9\u2075N\u2011analyse, voor volledige omzetting naar N\u2082<\/li>\n<li data-section-id=\"13wt8up\" data-start=\"2166\" data-end=\"2221\">Robuust reactorontwerp met lange levensduur<\/li>\n<li data-section-id=\"1awmhmf\" data-start=\"2222\" data-end=\"2285\">Minimale downtime bij het wisselen van GC\u2011kolommen en reactorbuizen<\/li>\n<\/ul>\n<h3 data-section-id=\"bxb3th\" data-start=\"2292\" data-end=\"2343\"><strong>Hoe verbetert het systeem de effici\u00ebntie van de workflow?<\/strong><\/h3>\n<p data-start=\"2345\" data-end=\"2459\">De GC5 is volledig ge\u00efntegreerd met de lyticOS\u00ae Software Suite, die geautomatiseerde Peak Mapping-functionaliteit bevat.<\/p>\n<p data-start=\"2461\" data-end=\"2474\"><strong>Dit zorgt voor:<\/strong><\/p>\n<ul data-start=\"2475\" data-end=\"2622\">\n<li data-section-id=\"oosz9r\" data-start=\"2475\" data-end=\"2520\">Snelle verwerking van complexe chromatogrammen<\/li>\n<li data-section-id=\"1j0jb9\" data-start=\"2521\" data-end=\"2572\">Automatische identificatie en uitlijning van pieken<\/li>\n<li data-section-id=\"1s3spdh\" data-start=\"2573\" data-end=\"2622\">Aanzienlijke reductie van dataverwerkingstijd<\/li>\n<\/ul>\n<p data-start=\"2624\" data-end=\"2700\">Hierdoor worden complexe datasets in minuten in plaats van uren verwerkt.<\/p>\n<h3 data-section-id=\"lrmpac\" data-start=\"3382\" data-end=\"3416\"><strong>Welke isotopen kunnen worden geanalyseerd?<\/strong><\/h3>\n<p data-start=\"3418\" data-end=\"3472\">De GC5 ondersteunt online isotopenverhoudingmetingen van:<\/p>\n<ul data-start=\"3473\" data-end=\"3512\">\n<li data-section-id=\"2gvugl\" data-start=\"3473\" data-end=\"3481\">\u03b4\u00b9\u00b3C<\/li>\n<li data-section-id=\"7der26\" data-start=\"3482\" data-end=\"3490\">\u03b4\u00b9\u2075N<\/li>\n<li data-section-id=\"91s6nr\" data-start=\"3491\" data-end=\"3503\">\u03b4\u00b2H (\u03b4D)<\/li>\n<li data-section-id=\"7dl8k2\" data-start=\"3504\" data-end=\"3512\">\u03b4\u00b9\u2078O<\/li>\n<\/ul>\n<p data-start=\"3514\" data-end=\"3602\">Capillaire gaschromatografie scheidt de verbindingen voorafgaand aan de meting.<\/p>\n<h3 data-section-id=\"oqfmgl\" data-start=\"3609\" data-end=\"3665\"><strong>Microreactortechnologie\u00a0<\/strong><\/h3>\n<p data-start=\"3667\" data-end=\"3765\">De GC5 maakt gebruik van microbore reactortechnologie om de chromatografische integriteit te behouden tijdens de verbranding.<\/p>\n<p data-start=\"3767\" data-end=\"3779\"><strong>Dit ontwerp:<\/strong><\/p>\n<ul data-start=\"3780\" data-end=\"3985\">\n<li data-section-id=\"6hvzs0\" data-start=\"3780\" data-end=\"3822\">Behoudt de piekvorm tijdens omzetting<\/li>\n<li data-section-id=\"p9mjp2\" data-start=\"3823\" data-end=\"3884\">Maakt nauwkeurige meting van dicht eluerende verbindingen mogelijk<\/li>\n<li data-section-id=\"wae4su\" data-start=\"3885\" data-end=\"3930\">Vermijdt kwetsbare keramische reactoronderdelen<\/li>\n<li data-section-id=\"1vz7x2j\" data-start=\"3931\" data-end=\"3985\">Ondersteunt hogetemperatuurgebruik tot 1.500\u202f\u00b0C<\/li>\n<\/ul>\n<p data-start=\"3987\" data-end=\"4089\">Element\u2011specifieke reactorconfiguraties zorgen voor optimale prestaties voor verschillende isotopensystemen.<\/p>\n<h3 data-section-id=\"5m6hev\" data-start=\"4783\" data-end=\"4811\"><strong>Multi\u2011isotopenflexibiliteit<\/strong><\/h3>\n<p data-start=\"4813\" data-end=\"4948\">De GC5 is ontworpen voor snel schakelen tussen isotopenmeetmodi en ondersteunt multi\u2011isotopenworkflows binnen \u00e9\u00e9n enkel platform.<\/p>\n<p data-start=\"4950\" data-end=\"5001\"><strong>Het maakt toepassingsspecifieke configuraties mogelijk voor:<\/strong><\/p>\n<ul data-start=\"5002\" data-end=\"5134\">\n<li data-section-id=\"srh1ho\" data-start=\"5002\" data-end=\"5047\">Koolstof en waterstof in aardolie-analyse<\/li>\n<li data-section-id=\"1yxcq8l\" data-start=\"5048\" data-end=\"5075\">Stikstof in aminozuren<\/li>\n<li data-section-id=\"2tn2vn\" data-start=\"5076\" data-end=\"5134\">Koolstof, waterstof en zuurstof in aroma\u2011 en geurstoffen<\/li>\n<\/ul>\n<p data-start=\"5136\" data-end=\"5240\">Deze flexibiliteit vereenvoudigt methodeontwikkeling en maakt het systeem aanpasbaar aan uiteenlopende onderzoeksbehoeften.<\/p>\n<h3 data-start=\"5136\" data-end=\"5240\"><strong>Monstertypes:\u00a0<\/strong><\/h3>\n<ul>\n<li>Alkanen<\/li>\n<li>PLFA's<\/li>\n<li>Biomarkers<\/li>\n<li>Aminozuren<\/li>\n<li>Koolhydraten<\/li>\n<li>Stero\u00efde extracten<\/li>\n<li>Ruwe oliefracties<\/li>\n<li>Aardgassen<\/li>\n<li>Drugs en verdovende middelen<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<p><script type=\"application\/ld+json\">{\n    \"@context\": \"https:\\\/\\\/schema.org\",\n    \"@type\": \"FAQPage\",\n    \"mainEntity\": [\n        {\n            \"@type\": \"Question\",\n            \"name\": \"What type of analysis is the GC5 designed for?\",\n            \"acceptedAnswer\": {\n                \"@type\": \"Answer\",\n                \"text\": \"The GC5 is designed for compound\\u2011specific isotope analysis, allowing individual compounds within complex mixtures to be separated by gas chromatography and measured by isotope ratio mass spectrometry.\"\n            }\n        },\n        {\n            \"@type\": \"Question\",\n            \"name\": \"Why is compound\\u2011specific isotope analysis important?\",\n            \"acceptedAnswer\": {\n                \"@type\": \"Answer\",\n                \"text\": \"Compound\\u2011specific isotope analysis enables researchers to study the origin, transformation pathways, and environmental or biological fate of individual compounds, which is essential in fields such as geochemistry, environmental science, and forensic investigations.\"\n            }\n        },\n        {\n            \"@type\": \"Question\",\n            \"name\": \"What level of sensitivity does the GC5 achieve?\",\n            \"acceptedAnswer\": {\n                \"@type\": \"Answer\",\n                \"text\": \"The GC5 delivers picomole\\u2011level detection sensitivity while preserving chromatographic peak integrity, making it suitable for analyzing compounds present at very low concentrations.\"\n            }\n        },\n        {\n            \"@type\": \"Question\",\n            \"name\": \"Which isotopes can be analyzed using the GC5?\",\n            \"acceptedAnswer\": {\n                \"@type\": \"Answer\",\n                \"text\": \"The GC5 supports online isotope ratio analysis of carbon, nitrogen, hydrogen, and oxygen, specifically \\u03b4\\u00b9\\u00b3C, \\u03b4\\u00b9\\u2075N, \\u03b4\\u00b2H, and \\u03b4\\u00b9\\u2078O.\"\n            }\n        },\n        {\n            \"@type\": \"Question\",\n            \"name\": \"What types of samples can be analyzed with the GC5?\",\n            \"acceptedAnswer\": {\n                \"@type\": \"Answer\",\n                \"text\": \"The system can analyze a wide range of sample types, including alkanes, PLFAs, biomarkers, amino acids, carbohydrates, steroid extracts, crude oil fractions, natural gases, drugs of abuse, and other compound classes.\"\n            }\n        }\n    ]\n}<\/script><\/p>\n<p><script type=\"application\/ld+json\">{\n    \"@context\": \"https:\\\/\\\/schema.org\\\/\",\n    \"@type\": \"Product\",\n    \"name\": \"GC5\",\n    \"image\": \"https:\\\/\\\/scispx.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/GC5.webp\",\n    \"description\": \"The GC5 is a gas chromatograph-based isotope ratio mass spectrometry (GC-IRMS) system for high-sensitivity compound-specific isotope analysis. It is ideal for advanced applications in biogeochemistry and forensic research, where detailed insight at the molecular level is required.\",\n    \"brand\": {\n        \"@type\": \"Brand\",\n        \"name\": \"Elementar\"\n    },\n    \"offers\": {\n        \"@type\": \"Offer\",\n        \"url\": \"https:\\\/\\\/scispx.com\\\/instruments\\\/gc5-gc-irms-system\\\/\",\n        \"priceCurrency\": \"EUR\",\n        \"price\": \"0\",\n        \"availability\": \"https:\\\/\\\/schema.org\\\/InStock\",\n        \"seller\": {\n            \"@type\": \"Organization\",\n            \"name\": \"SciSPX\",\n            \"url\": \"https:\\\/\\\/scispx.com\",\n            \"logo\": \"https:\\\/\\\/scispx.com\\\/wp-content\\\/uploads\\\/2025\\\/04\\\/SciSPX_RGB-Icon.png\",\n            \"areaServed\": [\n                {\n                    \"@type\": \"Country\",\n                    \"name\": \"Belgium\"\n                },\n                {\n                    \"@type\": \"Country\",\n                    \"name\": \"Netherlands\"\n                },\n                {\n                    \"@type\": \"Country\",\n                    \"name\": \"Luxembourg\"\n                }\n            ]\n        }\n    }\n}<\/script><\/p>","protected":false},"excerpt":{"rendered":"<p>GC\u2011IRMS\u2011systeem voor zeer gevoelige, stofspecifieke isotopenanalyse<\/p>","protected":false},"featured_media":5066,"template":"","brands":[133],"applications":[215,449],"markets":[17,16,15,36],"class_list":["post-5065","instruments","type-instruments","status-publish","has-post-thumbnail","hentry","brands-elementar","applications-analysis","applications-isotope-analyzers","markets-energy-and-sustainability","markets-environmental","markets-food-and-beverage","markets-soil-and-surface"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v25.5 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>GC5 | GC-IRMS system | SciSPX Analysis simplified<\/title>\n<meta name=\"description\" content=\"Gas chromatograph-based isotope ratio mass spectrometry (GC-IRMS) system developed for high-sensitivity compound-specific isotope analysis.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/scispx.com\/nl\/instruments\/gc5-gc-irms-system\/\" \/>\n<meta property=\"og:locale\" content=\"nl_NL\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"GC5 | GC-IRMS system | SciSPX Analysis simplified\" \/>\n<meta property=\"og:description\" content=\"Gas chromatograph-based isotope ratio mass spectrometry (GC-IRMS) system developed for high-sensitivity compound-specific isotope analysis.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/scispx.com\/nl\/instruments\/gc5-gc-irms-system\/\" \/>\n<meta property=\"og:site_name\" content=\"SciSPX Analysis simplified\" \/>\n<meta property=\"article:modified_time\" content=\"2026-10-12T07:24:49+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/scispx.com\/wp-content\/uploads\/2026\/04\/GC5.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"1080\" \/>\n\t<meta property=\"og:image:height\" content=\"1080\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Geschatte leestijd\" \/>\n\t<meta name=\"twitter:data1\" content=\"3 minuten\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/scispx.com\/nl\/instruments\/gc5-gc-irms-system\/\",\"url\":\"https:\/\/scispx.com\/nl\/instruments\/gc5-gc-irms-system\/\",\"name\":\"GC5 | GC-IRMS system | SciSPX Analysis simplified\",\"isPartOf\":{\"@id\":\"https:\/\/scispx.com\/nl\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/scispx.com\/nl\/instruments\/gc5-gc-irms-system\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/scispx.com\/nl\/instruments\/gc5-gc-irms-system\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/scispx.com\/wp-content\/uploads\/2026\/04\/GC5.webp\",\"datePublished\":\"2026-04-16T08:52:32+00:00\",\"dateModified\":\"2026-10-12T07:24:49+00:00\",\"description\":\"Gas chromatograph-based isotope ratio mass spectrometry (GC-IRMS) system developed for high-sensitivity compound-specific isotope analysis.\",\"breadcrumb\":{\"@id\":\"https:\/\/scispx.com\/nl\/instruments\/gc5-gc-irms-system\/#breadcrumb\"},\"inLanguage\":\"nl-NL\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/scispx.com\/nl\/instruments\/gc5-gc-irms-system\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"nl-NL\",\"@id\":\"https:\/\/scispx.com\/nl\/instruments\/gc5-gc-irms-system\/#primaryimage\",\"url\":\"https:\/\/scispx.com\/wp-content\/uploads\/2026\/04\/GC5.webp\",\"contentUrl\":\"https:\/\/scispx.com\/wp-content\/uploads\/2026\/04\/GC5.webp\",\"width\":1080,\"height\":1080,\"caption\":\"GC-IRMS system\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/scispx.com\/nl\/instruments\/gc5-gc-irms-system\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/scispx.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Instruments\",\"item\":\"https:\/\/scispx.com\/instruments\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"GC5\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/scispx.com\/nl\/#website\",\"url\":\"https:\/\/scispx.com\/nl\/\",\"name\":\"SciSPX Analysis simplified\",\"description\":\"SciSPX Analysis simplified\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/scispx.com\/nl\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"nl-NL\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"GC5 | GC-IRMS-systeem | SciSPX: analyse vereenvoudigd","description":"GC\u2011IRMS\u2011systeem op basis van gaschromatografie, ontwikkeld voor stofspecifieke isotopenanalyse met zeer hoge gevoeligheid.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/scispx.com\/nl\/instruments\/gc5-gc-irms-system\/","og_locale":"nl_NL","og_type":"article","og_title":"GC5 | GC-IRMS system | SciSPX Analysis simplified","og_description":"Gas chromatograph-based isotope ratio mass spectrometry (GC-IRMS) system developed for high-sensitivity compound-specific isotope analysis.","og_url":"https:\/\/scispx.com\/nl\/instruments\/gc5-gc-irms-system\/","og_site_name":"SciSPX Analysis simplified","article_modified_time":"2026-10-12T07:24:49+00:00","og_image":[{"width":1080,"height":1080,"url":"https:\/\/scispx.com\/wp-content\/uploads\/2026\/04\/GC5.webp","type":"image\/webp"}],"twitter_card":"summary_large_image","twitter_misc":{"Geschatte leestijd":"3 minuten"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/scispx.com\/nl\/instruments\/gc5-gc-irms-system\/","url":"https:\/\/scispx.com\/nl\/instruments\/gc5-gc-irms-system\/","name":"GC5 | GC-IRMS-systeem | SciSPX: analyse vereenvoudigd","isPartOf":{"@id":"https:\/\/scispx.com\/nl\/#website"},"primaryImageOfPage":{"@id":"https:\/\/scispx.com\/nl\/instruments\/gc5-gc-irms-system\/#primaryimage"},"image":{"@id":"https:\/\/scispx.com\/nl\/instruments\/gc5-gc-irms-system\/#primaryimage"},"thumbnailUrl":"https:\/\/scispx.com\/wp-content\/uploads\/2026\/04\/GC5.webp","datePublished":"2026-04-16T08:52:32+00:00","dateModified":"2026-10-12T07:24:49+00:00","description":"GC\u2011IRMS\u2011systeem op basis van gaschromatografie, ontwikkeld voor stofspecifieke isotopenanalyse met zeer hoge gevoeligheid.","breadcrumb":{"@id":"https:\/\/scispx.com\/nl\/instruments\/gc5-gc-irms-system\/#breadcrumb"},"inLanguage":"nl-NL","potentialAction":[{"@type":"ReadAction","target":["https:\/\/scispx.com\/nl\/instruments\/gc5-gc-irms-system\/"]}]},{"@type":"ImageObject","inLanguage":"nl-NL","@id":"https:\/\/scispx.com\/nl\/instruments\/gc5-gc-irms-system\/#primaryimage","url":"https:\/\/scispx.com\/wp-content\/uploads\/2026\/04\/GC5.webp","contentUrl":"https:\/\/scispx.com\/wp-content\/uploads\/2026\/04\/GC5.webp","width":1080,"height":1080,"caption":"GC-IRMS system"},{"@type":"BreadcrumbList","@id":"https:\/\/scispx.com\/nl\/instruments\/gc5-gc-irms-system\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/scispx.com\/"},{"@type":"ListItem","position":2,"name":"Instruments","item":"https:\/\/scispx.com\/instruments\/"},{"@type":"ListItem","position":3,"name":"GC5"}]},{"@type":"WebSite","@id":"https:\/\/scispx.com\/nl\/#website","url":"https:\/\/scispx.com\/nl\/","name":"SciSPX Analyse vereenvoudigd","description":"SciSPX Analyse vereenvoudigd","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/scispx.com\/nl\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"nl-NL"}]}},"_links":{"self":[{"href":"https:\/\/scispx.com\/nl\/wp-json\/wp\/v2\/instruments\/5065","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/scispx.com\/nl\/wp-json\/wp\/v2\/instruments"}],"about":[{"href":"https:\/\/scispx.com\/nl\/wp-json\/wp\/v2\/types\/instruments"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/scispx.com\/nl\/wp-json\/wp\/v2\/media\/5066"}],"wp:attachment":[{"href":"https:\/\/scispx.com\/nl\/wp-json\/wp\/v2\/media?parent=5065"}],"wp:term":[{"taxonomy":"brands","embeddable":true,"href":"https:\/\/scispx.com\/nl\/wp-json\/wp\/v2\/brands?post=5065"},{"taxonomy":"applications","embeddable":true,"href":"https:\/\/scispx.com\/nl\/wp-json\/wp\/v2\/applications?post=5065"},{"taxonomy":"markets","embeddable":true,"href":"https:\/\/scispx.com\/nl\/wp-json\/wp\/v2\/markets?post=5065"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}