{"id":4091,"date":"2025-05-26T14:24:39","date_gmt":"2025-05-26T12:24:39","guid":{"rendered":"https:\/\/scispx.com\/?post_type=instruments&#038;p=4091"},"modified":"2026-10-12T08:59:00","modified_gmt":"2026-10-12T06:59:00","slug":"marsxpress-2-0-systeme-scientifique-a-micro-ondes","status":"publish","type":"instruments","link":"https:\/\/scispx.com\/fr\/instruments\/marsxpress-2-0-systeme-scientifique-a-micro-ondes\/","title":{"rendered":"MARSXpress 2.0"},"content":{"rendered":"<h2 class=\"ml-0 mb-1 pl-0\">Syst\u00e8me scientifique \u00e0 micro-ondes<\/h2>\n<p class=\"isSelectedEnd\">Le MARSXpress 2.0 est un syst\u00e8me de digestion scientifique par micro-ondes qui simplifie la pr\u00e9paration courante des \u00e9chantillons. S'appuyant sur la technologie de r\u00e9cipients MARSXpress de CEM et sur les fonctionnalit\u00e9s XpressIntelligence, ce syst\u00e8me allie un assemblage simple des r\u00e9cipients, une programmation simplifi\u00e9e de la digestion, des tailles de lots flexibles et des fonctions de surveillance.<\/p>\n<p>Le MARSXpress 2.0 peut traiter entre 1 et 40 \u00e9chantillons en un seul lot, ce qui le rend adapt\u00e9 aussi bien aux \u00e9chantillons individuels qu\u2019aux protocoles de digestion \u00e0 haut d\u00e9bit.<\/p>\n<h3><strong>XpressIntelligence<\/strong><\/h3>\n<p class=\"isSelectedEnd\"><img decoding=\"async\" class=\"wp-image-4333 alignleft\" src=\"https:\/\/scispx.com\/wp-content\/uploads\/2025\/05\/xpresscommand-e1754643723557-300x189.webp\" alt=\"\" width=\"256\" height=\"161\" srcset=\"https:\/\/scispx.com\/wp-content\/uploads\/2025\/05\/xpresscommand-e1754643723557-300x189.webp 300w, https:\/\/scispx.com\/wp-content\/uploads\/2025\/05\/xpresscommand-e1754643723557-768x483.webp 768w, https:\/\/scispx.com\/wp-content\/uploads\/2025\/05\/xpresscommand-e1754643723557-18x12.webp 18w, https:\/\/scispx.com\/wp-content\/uploads\/2025\/05\/xpresscommand-e1754643723557.webp 1013w\" sizes=\"(max-width: 256px) 100vw, 256px\" \/><strong>XpressIntelligence<\/strong> associe trois technologies : la technologie MARSXpress pour les navires, XpressStart et XpressCommand.<\/p>\n<p class=\"isSelectedEnd\"><strong>XpressStart<\/strong> simplifie la programmation de la digestion par micro-ondes. L'utilisateur s\u00e9lectionne la temp\u00e9rature de traitement souhait\u00e9e et lance le syst\u00e8me. Celui-ci d\u00e9termine alors le type de r\u00e9cipients, leur nombre et leur emplacement dans le lot, ainsi que la puissance micro-ondes requise, le temps de mont\u00e9e en puissance et le temps de maintien.<\/p>\n<p class=\"isSelectedEnd\">Le MARSXpress 2.0 est ainsi adapt\u00e9 \u00e0 toutes les situations, qu\u2019il s\u2019agisse d\u2019un criblage portant sur un seul \u00e9chantillon ou d\u2019un lot pouvant compter jusqu\u2019\u00e0 40 \u00e9chantillons, sans que l\u2019utilisateur ait \u00e0 d\u00e9finir manuellement l\u2019ensemble des param\u00e8tres de digestion.<\/p>\n<p><strong>XpressCommand<\/strong> offre une fonctionnalit\u00e9 de commande vocale int\u00e9gr\u00e9e au syst\u00e8me XpressIntelligence.<\/p>\n<h3><strong>Navires MARSXpress et flexibilit\u00e9 des lots<\/strong><\/h3>\n<p class=\"isSelectedEnd\">Le MARSXpress 2.0 utilise la gamme de cuves MARSXpress. Ces cuves se caract\u00e9risent par une conception en trois parties qui facilite leur montage et leur utilisation.<\/p>\n<p class=\"isSelectedEnd\">Le syst\u00e8me peut traiter 1, 2, 3 ou jusqu'\u00e0 40 \u00e9chantillons par lot. Cela permet aux laboratoires de traiter un seul \u00e9chantillon pour une analyse urgente, d'effectuer un petit lot de d\u00e9pistage ou de traiter un lot complet de 40 \u00e9chantillons.<\/p>\n<p class=\"isSelectedEnd\">Les r\u00e9cipients MARSXpress sont disponibles en diff\u00e9rentes tailles, allant de 20 ml \u00e0 130 ml, ce qui permet au syst\u00e8me de s'adapter \u00e0 des \u00e9chantillons de diff\u00e9rentes tailles. Ces r\u00e9cipients sont parfaits pour la pr\u00e9paration courante des \u00e9chantillons et peuvent \u00eatre utilis\u00e9s pour des \u00e9chantillons alimentaires, environnementaux et autres.<\/p>\n<p>La gamme de r\u00e9cipients MARSXpress est utilis\u00e9e pour la digestion en vue d'analyses par ICP-MS ou ICP-OES. Ces r\u00e9cipients conviennent \u00e9galement aux m\u00e9thodes de digestion environnementales, notamment les m\u00e9thodes 3015a, 3051a et 3052 de l\u2019EPA am\u00e9ricaine, ainsi que les normes europ\u00e9ennes, les m\u00e9thodes AOAC, les normes ISO, les m\u00e9thodes ASTM et les essais CPSC.<\/p>\n<div class=\"rowTitle text-center\">\n<h3><strong>Quelle gamme de bateaux MARSXpress vous convient le mieux ?<\/strong><\/h3>\n<\/div>\n<table>\n<thead>\n<tr>\n<th><\/th>\n<th><strong>MARSXpress<\/strong><\/th>\n<th><strong>MARSXpress Plus<\/strong><\/th>\n<th><strong>MARSXpress Max<\/strong><\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><strong>Capacit\u00e9 du navire<\/strong><\/td>\n<td>40 navires<\/td>\n<td>24 navires<\/td>\n<td>24 navires<\/td>\n<\/tr>\n<tr>\n<td><strong>Volume du navire<\/strong><\/td>\n<td>20, 55 ou 75 ml<\/td>\n<td>110 ml<\/td>\n<td>130 ml<\/td>\n<\/tr>\n<tr>\n<td><strong>Temp\u00e9rature maximale<\/strong><\/td>\n<td>210 \u00b0C<\/td>\n<td>210 \u00b0C<\/td>\n<td>220 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td><strong>Instruments compatibles<\/strong><\/td>\n<td><a href=\"https:\/\/scispx.com\/fr\/instruments\/mars-6\/\" target=\"_blank\" rel=\"noopener\">\u2022 MARS 6<\/a><br \/>\n\u2022 MARSXpress 2.0<\/td>\n<td><a href=\"https:\/\/scispx.com\/fr\/instruments\/mars-6\/\" target=\"_blank\" rel=\"noopener\">\u2022 MARS 6<\/a><br \/>\n\u2022 MARSXpress 2.0<\/td>\n<td>\u2022 MARSXpress 2.0<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3><strong>Suivi de la digestion et des donn\u00e9es d'ex\u00e9cution<\/strong><\/h3>\n<p class=\"isSelectedEnd\">Le MARSXpress 2.0 offre plusieurs moyens de surveiller la digestion. L'indicateur visuel lumineux (VLI) permet de v\u00e9rifier l'\u00e9tat du syst\u00e8me depuis n'importe quel endroit du laboratoire, tandis que la fen\u00eatre d'observation du syst\u00e8me permet aux utilisateurs de suivre le d\u00e9roulement de la digestion.<\/p>\n<p class=\"isSelectedEnd\">Une fois le cycle termin\u00e9, les utilisateurs peuvent consulter les donn\u00e9es enregistr\u00e9es et visualiser les informations de temp\u00e9rature tout au long de la digestion. Une interface graphique permet de comparer la temp\u00e9rature atteinte par chaque \u00e9chantillon \u00e0 sa valeur de consigne.<\/p>\n<p class=\"isSelectedEnd\">Les rapports d'analyse peuvent \u00e9galement \u00eatre export\u00e9s et personnalis\u00e9s avec des informations sur les m\u00e9thodes, des graphiques de temp\u00e9rature et de puissance, ainsi que des donn\u00e9es d'\u00e9chantillons. Les rapports peuvent en outre comporter le logo de l'entreprise du laboratoire.<\/p>\n<h3><strong>R\u00e9gulation de la temp\u00e9rature et s\u00e9curit\u00e9<\/strong><\/h3>\n<p class=\"isSelectedEnd\">Le MARSXpress 2.0 utilise le capteur de temp\u00e9rature sans contact et in situ iWave pour mesurer la temp\u00e9rature des \u00e9chantillons. Ce capteur fournit des mesures de temp\u00e9rature quelle que soit la position de l'\u00e9chantillon dans la cavit\u00e9 micro-ondes ou le nombre d'\u00e9chantillons dans le lot. Apr\u00e8s la digestion, le syst\u00e8me refroidit automatiquement les \u00e9chantillons jusqu'\u00e0 une temp\u00e9rature pr\u00e9d\u00e9finie avant leur retrait.<\/p>\n<p class=\"isSelectedEnd\">Un capteur de pression diff\u00e9rentielle surveille les conditions n\u00e9cessaires \u00e0 l'\u00e9vacuation des vapeurs. Le syst\u00e8me v\u00e9rifie le d\u00e9bit d'air requis avant, pendant et apr\u00e8s le cycle de digestion et \u00e9met une alerte si les conditions requises ne sont pas respect\u00e9es.<\/p>\n<h3><strong>Pr\u00e9paration syst\u00e9matique d\u2019\u00e9chantillons \u00e0 haut d\u00e9bit<\/strong><\/h3>\n<p>Le MARSXpress 2.0 allie un montage simple des r\u00e9cipients, un traitement par lots flexible, des param\u00e8tres de digestion automatis\u00e9s et une surveillance de la temp\u00e9rature et de la pression pour la pr\u00e9paration de routine d'\u00e9chantillons par micro-ondes. Ses r\u00e9cipients MARSXpress\u2122 permettent de traiter jusqu'\u00e0 40 \u00e9chantillons par lot et conviennent \u00e0 diverses applications, notamment la digestion d'\u00e9chantillons environnementaux et alimentaires avant une analyse par ICP-MS ou ICP-OES.<\/p>\n<p><script type=\"application\/ld+json\">{\n    \"@context\": \"https:\\\/\\\/schema.org\",\n    \"@type\": \"FAQPage\",\n    \"mainEntity\": [\n        {\n            \"@type\": \"Question\",\n            \"name\": \"What is microwave digestion?\",\n            \"acceptedAnswer\": {\n                \"@type\": \"Answer\",\n                \"text\": \"Microwave digestion is a sample preparation technique that uses microwave energy, acids, pressure, and controlled temperature to dissolve samples before elemental analysis by ICP-MS, ICP-OES, or atomic absorption spectroscopy.\"\n            }\n        },\n        {\n            \"@type\": \"Question\",\n            \"name\": \"Why is microwave digestion important for elemental analysis?\",\n            \"acceptedAnswer\": {\n                \"@type\": \"Answer\",\n                \"text\": \"Microwave digestion converts solid and complex samples into homogeneous liquid solutions, improving element recovery, analytical accuracy, and reproducibility before instrumental analysis.\"\n            }\n        },\n        {\n            \"@type\": \"Question\",\n            \"name\": \"What is XpressIntelligence?\",\n            \"acceptedAnswer\": {\n                \"@type\": \"Answer\",\n                \"text\": \"XpressIntelligence is an integrated technology platform that combines MARSXpress vessel technology, XpressStart automated method setup, and XpressCommand voice functionality to simplify microwave digestion.\"\n            }\n        },\n        {\n            \"@type\": \"Question\",\n            \"name\": \"What is XpressStart?\",\n            \"acceptedAnswer\": {\n                \"@type\": \"Answer\",\n                \"text\": \"XpressStart is an intelligent microwave digestion feature that automatically determines digestion parameters based on vessel type, vessel position, vessel count, and target temperature.\"\n            }\n        },\n        {\n            \"@type\": \"Question\",\n            \"name\": \"What is the Visual Light Indicator (VLI)?\",\n            \"acceptedAnswer\": {\n                \"@type\": \"Answer\",\n                \"text\": \"The Visual Light Indicator is a status display that allows laboratory personnel to determine the operating condition of the microwave digestion system from across the laboratory.\"\n            }\n        },\n        {\n            \"@type\": \"Question\",\n            \"name\": \"What types of samples can be digested using the MARSXpress 2.0?\",\n            \"acceptedAnswer\": {\n                \"@type\": \"Answer\",\n                \"text\": \"The system is suitable for food, environmental, agricultural, industrial, pharmaceutical, and research samples requiring elemental analysis.\"\n            }\n        }\n    ]\n}<\/script><\/p>","protected":false},"excerpt":{"rendered":"<p>Syst\u00e8me scientifique de digestion par micro-ondes con\u00e7u pour simplifier la pr\u00e9paration courante des \u00e9chantillons<\/p>","protected":false},"featured_media":4092,"template":"","brands":[130],"applications":[217,213],"markets":[18,45,48,14,22,115,38,120,25,43,26,17,16,34,47,15,27,126,39,44,110,28,111,30,116,117,40,33,36,46,23,282,32,127,35,31],"class_list":["post-4091","instruments","type-instruments","status-publish","has-post-thumbnail","hentry","brands-cem","applications-digestion","applications-sample-prep","markets-agriculture","markets-agriculture-analysis-services","markets-animal-feed","markets-chemical-industry","markets-chemicals-chemicals","markets-chemicals-materials","markets-coal-coke-biomass","markets-construction-materials","markets-consumer-products","markets-crop-farming","markets-dairy","markets-energy-and-sustainability","markets-environmental","markets-environmental-services-and-equipment","markets-fertilizers-and-chemicals","markets-food-and-beverage","markets-fruit-and-vegetables","markets-inorganic-materials","markets-liquid-fuels","markets-livestock","markets-materials","markets-meat","markets-metals-and-mining","markets-oils-and-fats","markets-paper-packaging-products","markets-polymers-rubber","markets-refinery","markets-snacks","markets-soil-and-surface","markets-soil-and-water-conservation","markets-specialty-chemicals","markets-structural-and-civil-engineering","markets-sugar-industry","markets-waste-management","markets-wastewater-treatment","markets-water-and-soft-drinks"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v25.5 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>MARSXpress 2.0 | Scientific Microwave System | SciSPX Analysis simplified<\/title>\n<meta name=\"description\" content=\"Scientific Microwave Digestion system designed to simplify routine sample preparation, featuring batch processing from 1 to 40 samples.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/scispx.com\/fr\/instruments\/marsxpress-2-0-systeme-scientifique-a-micro-ondes\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"MARSXpress 2.0 | Scientific Microwave System | SciSPX Analysis simplified\" \/>\n<meta property=\"og:description\" content=\"Scientific Microwave Digestion system designed to simplify routine sample preparation, featuring batch processing from 1 to 40 samples.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/scispx.com\/fr\/instruments\/marsxpress-2-0-systeme-scientifique-a-micro-ondes\/\" \/>\n<meta property=\"og:site_name\" content=\"SciSPX Analysis simplified\" \/>\n<meta property=\"article:modified_time\" content=\"2026-10-12T06:59:00+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/scispx.com\/wp-content\/uploads\/2025\/05\/MARSXpress2.0_Straight-On_Std_Web.png\" \/>\n\t<meta property=\"og:image:width\" content=\"800\" \/>\n\t<meta property=\"og:image:height\" content=\"800\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Dur\u00e9e de lecture estim\u00e9e\" \/>\n\t<meta name=\"twitter:data1\" content=\"4 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/scispx.com\/fr\/instruments\/marsxpress-2-0-systeme-scientifique-a-micro-ondes\/\",\"url\":\"https:\/\/scispx.com\/fr\/instruments\/marsxpress-2-0-systeme-scientifique-a-micro-ondes\/\",\"name\":\"MARSXpress 2.0 | Scientific Microwave System | SciSPX Analysis simplified\",\"isPartOf\":{\"@id\":\"https:\/\/scispx.com\/fr\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/scispx.com\/fr\/instruments\/marsxpress-2-0-systeme-scientifique-a-micro-ondes\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/scispx.com\/fr\/instruments\/marsxpress-2-0-systeme-scientifique-a-micro-ondes\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/scispx.com\/wp-content\/uploads\/2025\/05\/MARSXpress2.0_Straight-On_Std_Web.png\",\"datePublished\":\"2025-05-26T12:24:39+00:00\",\"dateModified\":\"2026-10-12T06:59:00+00:00\",\"description\":\"Scientific Microwave Digestion system designed to simplify routine sample preparation, featuring batch processing from 1 to 40 samples.\",\"breadcrumb\":{\"@id\":\"https:\/\/scispx.com\/fr\/instruments\/marsxpress-2-0-systeme-scientifique-a-micro-ondes\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/scispx.com\/fr\/instruments\/marsxpress-2-0-systeme-scientifique-a-micro-ondes\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/scispx.com\/fr\/instruments\/marsxpress-2-0-systeme-scientifique-a-micro-ondes\/#primaryimage\",\"url\":\"https:\/\/scispx.com\/wp-content\/uploads\/2025\/05\/MARSXpress2.0_Straight-On_Std_Web.png\",\"contentUrl\":\"https:\/\/scispx.com\/wp-content\/uploads\/2025\/05\/MARSXpress2.0_Straight-On_Std_Web.png\",\"width\":800,\"height\":800,\"caption\":\"Scientific microwave system\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/scispx.com\/fr\/instruments\/marsxpress-2-0-systeme-scientifique-a-micro-ondes\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/scispx.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Instruments\",\"item\":\"https:\/\/scispx.com\/instruments\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"MARSXpress 2.0\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/scispx.com\/fr\/#website\",\"url\":\"https:\/\/scispx.com\/fr\/\",\"name\":\"SciSPX Analysis simplified\",\"description\":\"SciSPX Analysis simplified\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/scispx.com\/fr\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"MARSXpress 2.0 | Syst\u00e8me scientifique \u00e0 micro-ondes | SciSPX : l'analyse simplifi\u00e9e","description":"Syst\u00e8me de digestion par micro-ondes \u00e0 usage scientifique, con\u00e7u pour simplifier la pr\u00e9paration courante des \u00e9chantillons, permettant le traitement par lots de 1 \u00e0 40 \u00e9chantillons.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/scispx.com\/fr\/instruments\/marsxpress-2-0-systeme-scientifique-a-micro-ondes\/","og_locale":"fr_FR","og_type":"article","og_title":"MARSXpress 2.0 | Scientific Microwave System | SciSPX Analysis simplified","og_description":"Scientific Microwave Digestion system designed to simplify routine sample preparation, featuring batch processing from 1 to 40 samples.","og_url":"https:\/\/scispx.com\/fr\/instruments\/marsxpress-2-0-systeme-scientifique-a-micro-ondes\/","og_site_name":"SciSPX Analysis simplified","article_modified_time":"2026-10-12T06:59:00+00:00","og_image":[{"width":800,"height":800,"url":"https:\/\/scispx.com\/wp-content\/uploads\/2025\/05\/MARSXpress2.0_Straight-On_Std_Web.png","type":"image\/png"}],"twitter_card":"summary_large_image","twitter_misc":{"Dur\u00e9e de lecture estim\u00e9e":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/scispx.com\/fr\/instruments\/marsxpress-2-0-systeme-scientifique-a-micro-ondes\/","url":"https:\/\/scispx.com\/fr\/instruments\/marsxpress-2-0-systeme-scientifique-a-micro-ondes\/","name":"MARSXpress 2.0 | Syst\u00e8me scientifique \u00e0 micro-ondes | SciSPX : l'analyse simplifi\u00e9e","isPartOf":{"@id":"https:\/\/scispx.com\/fr\/#website"},"primaryImageOfPage":{"@id":"https:\/\/scispx.com\/fr\/instruments\/marsxpress-2-0-systeme-scientifique-a-micro-ondes\/#primaryimage"},"image":{"@id":"https:\/\/scispx.com\/fr\/instruments\/marsxpress-2-0-systeme-scientifique-a-micro-ondes\/#primaryimage"},"thumbnailUrl":"https:\/\/scispx.com\/wp-content\/uploads\/2025\/05\/MARSXpress2.0_Straight-On_Std_Web.png","datePublished":"2025-05-26T12:24:39+00:00","dateModified":"2026-10-12T06:59:00+00:00","description":"Syst\u00e8me de digestion par micro-ondes \u00e0 usage scientifique, con\u00e7u pour simplifier la pr\u00e9paration courante des \u00e9chantillons, permettant le traitement par lots de 1 \u00e0 40 \u00e9chantillons.","breadcrumb":{"@id":"https:\/\/scispx.com\/fr\/instruments\/marsxpress-2-0-systeme-scientifique-a-micro-ondes\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/scispx.com\/fr\/instruments\/marsxpress-2-0-systeme-scientifique-a-micro-ondes\/"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/scispx.com\/fr\/instruments\/marsxpress-2-0-systeme-scientifique-a-micro-ondes\/#primaryimage","url":"https:\/\/scispx.com\/wp-content\/uploads\/2025\/05\/MARSXpress2.0_Straight-On_Std_Web.png","contentUrl":"https:\/\/scispx.com\/wp-content\/uploads\/2025\/05\/MARSXpress2.0_Straight-On_Std_Web.png","width":800,"height":800,"caption":"Scientific microwave system"},{"@type":"BreadcrumbList","@id":"https:\/\/scispx.com\/fr\/instruments\/marsxpress-2-0-systeme-scientifique-a-micro-ondes\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/scispx.com\/"},{"@type":"ListItem","position":2,"name":"Instruments","item":"https:\/\/scispx.com\/instruments\/"},{"@type":"ListItem","position":3,"name":"MARSXpress 2.0"}]},{"@type":"WebSite","@id":"https:\/\/scispx.com\/fr\/#website","url":"https:\/\/scispx.com\/fr\/","name":"SciSPX Analyse simplifi\u00e9e","description":"SciSPX Analyse simplifi\u00e9e","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/scispx.com\/fr\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"}]}},"_links":{"self":[{"href":"https:\/\/scispx.com\/fr\/wp-json\/wp\/v2\/instruments\/4091","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/scispx.com\/fr\/wp-json\/wp\/v2\/instruments"}],"about":[{"href":"https:\/\/scispx.com\/fr\/wp-json\/wp\/v2\/types\/instruments"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/scispx.com\/fr\/wp-json\/wp\/v2\/media\/4092"}],"wp:attachment":[{"href":"https:\/\/scispx.com\/fr\/wp-json\/wp\/v2\/media?parent=4091"}],"wp:term":[{"taxonomy":"brands","embeddable":true,"href":"https:\/\/scispx.com\/fr\/wp-json\/wp\/v2\/brands?post=4091"},{"taxonomy":"applications","embeddable":true,"href":"https:\/\/scispx.com\/fr\/wp-json\/wp\/v2\/applications?post=4091"},{"taxonomy":"markets","embeddable":true,"href":"https:\/\/scispx.com\/fr\/wp-json\/wp\/v2\/markets?post=4091"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}