{"id":3546,"date":"2025-01-16T16:04:58","date_gmt":"2025-01-16T15:04:58","guid":{"rendered":"https:\/\/scispx.com\/?post_type=instruments&#038;p=3546"},"modified":"2025-05-27T14:55:07","modified_gmt":"2025-05-27T12:55:07","slug":"nex-xt-analyseur-de-soufre-en-ligne","status":"publish","type":"instruments","link":"https:\/\/scispx.com\/fr\/instruments\/nex-xt\/","title":{"rendered":"NEX XT"},"content":{"rendered":"<div class=\"lg:col-start-1 lg:col-span-6\">\n<div class=\"my-4 hs-search-keyword [&amp;_h2]:font-montserrat [&amp;_h2]:font-normal [&amp;_h2]:text-rigaku-dark-blue [&amp;_h2]:text-[28px] [&amp;_h3]:font-roboto [&amp;_h3]:font-bold [&amp;_h3]:text-lg [&amp;_h3]:text-[#363c3f] [&amp;_ul]:list-disc [&amp;_ol]:list-decimal [&amp;_ul]:list-outside [&amp;_ul]:pl-8 [&amp;_ul]:pt-2 [&amp;_ol]:pl-8 [&amp;_ol]:pt-2\">\n<h2>Analyseur de soufre en ligne<\/h2>\n<div class=\"text-base my-auto mx-auto py-5 [--thread-content-margin:--spacing(4)] @[37rem]:[--thread-content-margin:--spacing(6)] @[72rem]:[--thread-content-margin:--spacing(16)] px-(--thread-content-margin)\">\n<div class=\"[--thread-content-max-width:32rem] @[34rem]:[--thread-content-max-width:40rem] @[64rem]:[--thread-content-max-width:48rem] mx-auto flex max-w-(--thread-content-max-width) flex-1 text-base gap-4 md:gap-5 lg:gap-6 group\/turn-messages focus-visible:outline-hidden\" tabindex=\"-1\">\n<div class=\"group\/conversation-turn relative flex w-full min-w-0 flex-col agent-turn\">\n<div class=\"relative flex-col gap-1 md:gap-3\">\n<div class=\"flex max-w-full flex-col grow\">\n<div class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal [.text-message+&amp;]:mt-5\" dir=\"auto\" data-message-author-role=\"assistant\" data-message-id=\"1241e7f2-5776-4fdd-a2d3-db17dcd520fb\" data-message-model-slug=\"gpt-4o-mini\">\n<div class=\"flex w-full flex-col gap-1 empty:hidden first:pt-[3px]\">\n<div class=\"markdown prose dark:prose-invert w-full break-words light\">\n<p data-start=\"0\" data-end=\"204\" data-is-last-node=\"\" data-is-only-node=\"\">Le NEX XT offre des mesures en ligne et en temps r\u00e9el par transmission de rayons X (XRT) du soufre, avec des concentrations allant de 0.04 \u00e0 6wt%, dans divers flux p\u00e9troliers (p\u00e9trole brut, fioul lourd et autres hydrocarbures tr\u00e8s visqueux), quel que soit le type de flux.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<div>\n<div class=\"my-4 hs-search-keyword [&amp;_h2]:font-montserrat [&amp;_h2]:font-normal [&amp;_h2]:text-rigaku-dark-blue [&amp;_h2]:text-[28px] [&amp;_h3]:font-roboto [&amp;_h3]:font-bold [&amp;_h3]:text-lg [&amp;_h3]:text-[#363c3f] [&amp;_ul]:list-disc [&amp;_ol]:list-decimal [&amp;_ul]:list-outside [&amp;_ul]:pl-8 [&amp;_ul]:pt-2 [&amp;_ol]:pl-8 [&amp;_ol]:pt-2\">\n<p>Le NEX XT r\u00e9pond aux exigences vari\u00e9es de l\u2019industrie.<\/p>\n<\/div>\n<\/div>\n<p>C\u2019est un analyseur compact, polyvalent et robuste de transmission\/absorption de rayons X, sp\u00e9cialement con\u00e7u pour l\u2019analyse totale du soufre dans les raffineries, les ol\u00e9oducs, les processus de m\u00e9lange et autres installations de stockage.<\/p>\n<p>&nbsp;<\/p>\n<h3><strong>Applications du NEX XT :<\/strong><\/h3>\n<p>Le NEX XT fournit des mesures en ligne et en temps r\u00e9el par transmission de rayons X (XRT) du soufre, allant de 400 parties par million (ppm) \u00e0 6\u202f% en poids, sur divers flux p\u00e9troliers. Il repr\u00e9sente la nouvelle g\u00e9n\u00e9ration de solutions de processus pour la mesure du soufre dans le p\u00e9trole brut, le fioul marin, les huiles combustibles et d\u2019autres hydrocarbures tr\u00e8s visqueux.<\/p>\n<ul>\n<li>M\u00e9lange et suivi du p\u00e9trole brut et des mati\u00e8res premi\u00e8res de raffinage<\/li>\n<li>M\u00e9lange et suivi des carburants marins pour conformit\u00e9 aux r\u00e9glementations <a href=\"https:\/\/www.imo.org\/en\/about\/Conventions\/Pages\/International-Convention-for-the-Prevention-of-Pollution-from-Ships-(MARPOL).aspx\" target=\"_blank\" rel=\"noopener\">OMI MARPOL<\/a> .<\/li>\n<li>Contr\u00f4le qualit\u00e9 du p\u00e9trole brut dans les installations de collecte et de stockage \u00e9loign\u00e9es<\/li>\n<li>Suivi des huiles de gaz \u00e0 vide \u00e0 haute temp\u00e9rature<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<h3><strong>Plus rapide et plus sensible<\/strong><\/h3>\n<p>Gr\u00e2ce \u00e0 du mat\u00e9riel sp\u00e9cialement d\u00e9velopp\u00e9 et \u00e0 des technologies logicielles innovantes propri\u00e9taires, le syst\u00e8me NEX XT est plus rapide, plus sensible et beaucoup plus compact que les syst\u00e8mes concurrents. Le NEX XT effectue des mesures continues et fiables du soufre \u00e0 des pressions allant jusqu\u2019\u00e0 100 bars et des temp\u00e9ratures jusqu\u2019\u00e0 200\u00b0C, dans des configurations personnalis\u00e9es. Le NEX XT fonctionne comme un analyseur autonome ou fournit un contr\u00f4le en boucle ferm\u00e9e en temps r\u00e9el lorsqu\u2019il est int\u00e9gr\u00e9 dans un syst\u00e8me de m\u00e9lange ou d\u2019automatisation \u00e0 l\u2019\u00e9chelle industrielle.<\/p>\n<p>Parmi les autres caract\u00e9ristiques cl\u00e9s figurent une interface utilisateur simplifi\u00e9e, une moindre d\u00e9pendance aux \u00e9talons de calibration, une correction automatique de la densit\u00e9, une protection par mot de passe, ainsi qu\u2019une plateforme standardis\u00e9e pour la communication des r\u00e9sultats de soufre vers un DCS (Distributed Control System).\u2003<\/p>\n<p>&nbsp;<\/p>\n<\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Analyseur de soufre en continu pour flux p\u00e9troliers<\/p>","protected":false},"featured_media":3548,"template":"","brands":[444],"applications":[231,445],"markets":[48,443,116],"class_list":["post-3546","instruments","type-instruments","status-publish","has-post-thumbnail","hentry","brands-rigaku","applications-elemental-analysis","applications-xrf","markets-animal-feed","markets-packaging","markets-paper-packaging-products"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v25.5 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>NEX XT<\/title>\n<meta name=\"description\" content=\"Sulfur process analyzer for total sulfur measurements ranging from 0.04 to 6 wt% in crude oil, bunker fuel, fuel oils, and more.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/scispx.com\/fr\/instruments\/nex-xt\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"NEX XT\" \/>\n<meta property=\"og:description\" content=\"Sulfur process analyzer for total sulfur measurements ranging from 0.04 to 6 wt% in crude oil, bunker fuel, fuel oils, and more.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/scispx.com\/fr\/instruments\/nex-xt\/\" \/>\n<meta property=\"og:site_name\" content=\"SciSPX Analysis simplified\" \/>\n<meta property=\"article:modified_time\" content=\"2025-05-27T12:55:07+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/scispx.com\/wp-content\/uploads\/2025\/01\/NEX-XT-inline.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"800\" \/>\n\t<meta property=\"og:image:height\" content=\"610\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Dur\u00e9e de lecture estim\u00e9e\" \/>\n\t<meta name=\"twitter:data1\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/scispx.com\/fr\/instruments\/nex-xt\/\",\"url\":\"https:\/\/scispx.com\/fr\/instruments\/nex-xt\/\",\"name\":\"NEX XT\",\"isPartOf\":{\"@id\":\"https:\/\/scispx.com\/fr\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/scispx.com\/fr\/instruments\/nex-xt\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/scispx.com\/fr\/instruments\/nex-xt\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/scispx.com\/wp-content\/uploads\/2025\/01\/NEX-XT-inline.jpg\",\"datePublished\":\"2025-01-16T15:04:58+00:00\",\"dateModified\":\"2025-05-27T12:55:07+00:00\",\"description\":\"Sulfur process analyzer for total sulfur measurements ranging from 0.04 to 6 wt% in crude oil, bunker fuel, fuel oils, and more.\",\"breadcrumb\":{\"@id\":\"https:\/\/scispx.com\/fr\/instruments\/nex-xt\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/scispx.com\/fr\/instruments\/nex-xt\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/scispx.com\/fr\/instruments\/nex-xt\/#primaryimage\",\"url\":\"https:\/\/scispx.com\/wp-content\/uploads\/2025\/01\/NEX-XT-inline.jpg\",\"contentUrl\":\"https:\/\/scispx.com\/wp-content\/uploads\/2025\/01\/NEX-XT-inline.jpg\",\"width\":800,\"height\":610,\"caption\":\"Sulfur process analyzer\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/scispx.com\/fr\/instruments\/nex-xt\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/scispx.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Instruments\",\"item\":\"https:\/\/scispx.com\/instruments\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"NEX XT\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/scispx.com\/fr\/#website\",\"url\":\"https:\/\/scispx.com\/fr\/\",\"name\":\"SciSPX Analysis simplified\",\"description\":\"SciSPX Analysis simplified\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/scispx.com\/fr\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"NEX XT","description":"Analyseur de soufre pour mesures du soufre total allant de 0,04 \u00e0 6\u202f% en poids dans le p\u00e9trole brut, le fioul marin, les huiles combustibles,...","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/scispx.com\/fr\/instruments\/nex-xt\/","og_locale":"fr_FR","og_type":"article","og_title":"NEX XT","og_description":"Sulfur process analyzer for total sulfur measurements ranging from 0.04 to 6 wt% in crude oil, bunker fuel, fuel oils, and more.","og_url":"https:\/\/scispx.com\/fr\/instruments\/nex-xt\/","og_site_name":"SciSPX Analysis simplified","article_modified_time":"2025-05-27T12:55:07+00:00","og_image":[{"width":800,"height":610,"url":"https:\/\/scispx.com\/wp-content\/uploads\/2025\/01\/NEX-XT-inline.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Dur\u00e9e de lecture estim\u00e9e":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/scispx.com\/fr\/instruments\/nex-xt\/","url":"https:\/\/scispx.com\/fr\/instruments\/nex-xt\/","name":"NEX XT","isPartOf":{"@id":"https:\/\/scispx.com\/fr\/#website"},"primaryImageOfPage":{"@id":"https:\/\/scispx.com\/fr\/instruments\/nex-xt\/#primaryimage"},"image":{"@id":"https:\/\/scispx.com\/fr\/instruments\/nex-xt\/#primaryimage"},"thumbnailUrl":"https:\/\/scispx.com\/wp-content\/uploads\/2025\/01\/NEX-XT-inline.jpg","datePublished":"2025-01-16T15:04:58+00:00","dateModified":"2025-05-27T12:55:07+00:00","description":"Analyseur de soufre pour mesures du soufre total allant de 0,04 \u00e0 6\u202f% en poids dans le p\u00e9trole brut, le fioul marin, les huiles combustibles,...","breadcrumb":{"@id":"https:\/\/scispx.com\/fr\/instruments\/nex-xt\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/scispx.com\/fr\/instruments\/nex-xt\/"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/scispx.com\/fr\/instruments\/nex-xt\/#primaryimage","url":"https:\/\/scispx.com\/wp-content\/uploads\/2025\/01\/NEX-XT-inline.jpg","contentUrl":"https:\/\/scispx.com\/wp-content\/uploads\/2025\/01\/NEX-XT-inline.jpg","width":800,"height":610,"caption":"Sulfur process analyzer"},{"@type":"BreadcrumbList","@id":"https:\/\/scispx.com\/fr\/instruments\/nex-xt\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/scispx.com\/"},{"@type":"ListItem","position":2,"name":"Instruments","item":"https:\/\/scispx.com\/instruments\/"},{"@type":"ListItem","position":3,"name":"NEX XT"}]},{"@type":"WebSite","@id":"https:\/\/scispx.com\/fr\/#website","url":"https:\/\/scispx.com\/fr\/","name":"SciSPX Analyse simplifi\u00e9e","description":"SciSPX Analyse simplifi\u00e9e","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/scispx.com\/fr\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"}]}},"_links":{"self":[{"href":"https:\/\/scispx.com\/fr\/wp-json\/wp\/v2\/instruments\/3546","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/scispx.com\/fr\/wp-json\/wp\/v2\/instruments"}],"about":[{"href":"https:\/\/scispx.com\/fr\/wp-json\/wp\/v2\/types\/instruments"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/scispx.com\/fr\/wp-json\/wp\/v2\/media\/3548"}],"wp:attachment":[{"href":"https:\/\/scispx.com\/fr\/wp-json\/wp\/v2\/media?parent=3546"}],"wp:term":[{"taxonomy":"brands","embeddable":true,"href":"https:\/\/scispx.com\/fr\/wp-json\/wp\/v2\/brands?post=3546"},{"taxonomy":"applications","embeddable":true,"href":"https:\/\/scispx.com\/fr\/wp-json\/wp\/v2\/applications?post=3546"},{"taxonomy":"markets","embeddable":true,"href":"https:\/\/scispx.com\/fr\/wp-json\/wp\/v2\/markets?post=3546"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}