{"id":1205,"date":"2022-12-21T17:09:53","date_gmt":"2022-12-21T16:09:53","guid":{"rendered":"https:\/\/scispx.com\/instruments\/blade\/"},"modified":"2026-10-12T08:37:16","modified_gmt":"2026-10-12T06:37:16","slug":"blade-systeme-de-digestion-par-micro-ondes","status":"publish","type":"instruments","link":"https:\/\/scispx.com\/fr\/instruments\/blade\/","title":{"rendered":"Blade"},"content":{"rendered":"<h2>Syst\u00e8me automatis\u00e9 de digestion par micro-ondes pour tous les types d'\u00e9chantillons<\/h2>\n<p>Le syst\u00e8me de digestion par micro-ondes BLADE <strong>simplifie la pr\u00e9paration des \u00e9chantillons \u00e9l\u00e9mentaires tout en augmentant le rendement du laboratoire<\/strong>. En alliant une digestion rapide, une manipulation simplifi\u00e9e des r\u00e9cipients, des flux de travail automatis\u00e9s et un traitement flexible des \u00e9chantillons, ce syst\u00e8me permet aux laboratoires de traiter un large \u00e9ventail d'\u00e9chantillons plus rapidement, sans compromettre ni les performances ni la tra\u00e7abilit\u00e9.<\/p>\n<h3><strong>Digestion rapide par micro-ondes pour un d\u00e9bit accru<\/strong><\/h3>\n<p class=\"isSelectedEnd\">Le BLADE a \u00e9t\u00e9 con\u00e7u pour les laboratoires o\u00f9 le d\u00e9bit est une priorit\u00e9. Il associe une technologie de vortex avanc\u00e9e \u00e0 la technologie Single Mode Cavity\u2122 (SMC) de CEM afin de fournir une densit\u00e9 de puissance \u00e9lev\u00e9e directement \u00e0 chaque \u00e9chantillon. Cela permet de <strong>des digestions plus claires en un temps record<\/strong> n\u00e9cessaires aux syst\u00e8mes traditionnels de digestion par micro-ondes.<\/p>\n<p class=\"isSelectedEnd\">Les cycles de digestion complets, y compris le refroidissement, sont men\u00e9s \u00e0 bien<strong> en quelques minutes.<\/strong> \u00c9tant donn\u00e9 que les \u00e9chantillons et les combinaisons d'acides peuvent \u00eatre m\u00e9lang\u00e9s au cours d'une m\u00eame s\u00e9quence de traitement, les laboratoires passent moins de temps \u00e0 organiser des lots de digestion distincts. Le syst\u00e8me permet \u00e9galement aux utilisateurs d'interrompre une file d'attente d'\u00e9chantillons en cours pour ajouter des \u00e9chantillons prioritaires ou urgents sans perturber le flux de travail global.<\/p>\n<p>Une fois la digestion termin\u00e9e, le portoir d'\u00e9chantillons peut \u00eatre facilement retir\u00e9 et transport\u00e9 vers la hotte pour la dilution finale, ce qui r\u00e9duit les \u00e9tapes de manipulation et favorise un fonctionnement efficace du laboratoire.<\/p>\n<h3><strong>Pr\u00e9paration simple du r\u00e9cipient<\/strong><\/h3>\n<p class=\"isSelectedEnd\">La pr\u00e9paration de l'\u00e9chantillon est con\u00e7ue pour n\u00e9cessiter un minimum d'intervention manuelle. Les utilisateurs versent l'\u00e9chantillon, le barreau d'agitation et l'acide dans le r\u00e9cipient en quartz de haute puret\u00e9 avant de fixer le bouchon Easy Snap Cap.<img decoding=\"async\" class=\"wp-image-4162 alignright\" src=\"https:\/\/beunderonde.nl\/wp-content\/uploads\/2022\/10\/blade_simple_vessel-300x180.jpg\" alt=\"Vase \u00e0 lames\" width=\"300\" height=\"128\" \/><\/p>\n<p class=\"isSelectedEnd\">Le bouchon Easy Snap assure une \u00e9tanch\u00e9it\u00e9 parfaite sans n\u00e9cessiter d'assemblage du r\u00e9cipient ni de serrage. Une fois la digestion termin\u00e9e, le bouchon peut \u00eatre retir\u00e9 imm\u00e9diatement pour permettre la dilution. Ce bouchon \u00e9tant jetable, il n'est pas n\u00e9cessaire de nettoyer les bouchons d'\u00e9tanch\u00e9it\u00e9 ni les bouchons r\u00e9utilisables des r\u00e9cipients, ce qui r\u00e9duit le temps consacr\u00e9 \u00e0 la pr\u00e9paration et au nettoyage.<\/p>\n<p class=\"isSelectedEnd\">Le BLADE utilise un seul r\u00e9cipient en quartz de haute puret\u00e9 pour les applications courantes, ce qui \u00e9vite d'avoir \u00e0 g\u00e9rer plusieurs tailles de r\u00e9cipients. Pour l'acide fluorhydrique (HF) ou d'autres applications sp\u00e9cialis\u00e9es, un rev\u00eatement en PTFE enti\u00e8rement en contact avec le fluide est disponible.<\/p>\n<p>Le processus de digestion lui-m\u00eame est tout aussi simple. Une fois le r\u00e9cipient plac\u00e9 dans l'\u00e9chantillonneur automatique, il suffit de s\u00e9lectionner la m\u00e9thode souhait\u00e9e et le syst\u00e8me effectue automatiquement le cycle de digestion, y compris le refroidissement.<\/p>\n<h3><strong>Automatisation du flux de travail, de la mise en balance \u00e0 l'analyse<\/strong><\/h3>\n<p class=\"isSelectedEnd\">Le BLADE prend en charge les flux de travail en laboratoire au-del\u00e0 de la simple digestion. La lecture des codes-barres permet de suivre les \u00e9chantillons de la balance jusqu'\u00e0 l'analyse, tandis que l'automatisation s\u00e9quentielle continue assure un traitement ininterrompu des \u00e9chantillons.<\/p>\n<p class=\"isSelectedEnd\">Contrairement aux syst\u00e8mes classiques, le BLADE charge automatiquement les r\u00e9cipients dans la cavit\u00e9 micro-ondes, scelle chaque r\u00e9cipient individuellement, d\u00e9charge les r\u00e9cipients apr\u00e8s la digestion et les replace sur le portoir \u00e0 \u00e9chantillons une fois refroidis. Aucun chargement manuel des r\u00e9cipients, aucune pince, aucune \u00e9tape de pressurisation externe ni aucun d\u00e9chargement manuel ne sont n\u00e9cessaires. Cette automatisation r\u00e9duit au minimum l'exposition de l'op\u00e9rateur aux acides et aux vapeurs acides tout en optimisant le temps de fonctionnement de l'instrument.<\/p>\n<h3><strong>Pr\u00e9paration flexible des \u00e9chantillons<\/strong><\/h3>\n<p class=\"isSelectedEnd\">Le syst\u00e8me permet de traiter un large \u00e9ventail de types d'\u00e9chantillons \u00e0 l'aide de m\u00e9thodes de digestion pr\u00e9programm\u00e9es. <strong>Il est capable de d\u00e9composer des mati\u00e8res organiques simples, notamment des \u00e9chantillons alimentaires et v\u00e9g\u00e9taux<\/strong>, ainsi que des matrices plus exigeantes telles que le fioul de soute, le PET et les catalyseurs. Diff\u00e9rents types d'\u00e9chantillons et diff\u00e9rentes combinaisons d'acides peuvent \u00eatre trait\u00e9s au cours d'une m\u00eame s\u00e9quence.<\/p>\n<p class=\"isSelectedEnd\"><strong>Les m\u00e9thodes disponibles prennent en charge les acides suivants :<\/strong><\/p>\n<ul data-spread=\"false\">\n<li>Acide nitrique (HNO\u2083)<\/li>\n<li>Acide chlorhydrique (HCl)<\/li>\n<li>Acide fluorhydrique (HF)<\/li>\n<\/ul>\n<p>Les m\u00e9thodes pr\u00e9programm\u00e9es \u00e9vitent d'avoir \u00e0 mettre au point des m\u00e9thodes de routine et fournissent des recommandations concernant la taille des \u00e9chantillons et le choix de l'acide, aidant ainsi les laboratoires \u00e0 s\u00e9lectionner les conditions de digestion appropri\u00e9es.<\/p>\n<h3><strong>Surveillance et fonctionnement du syst\u00e8me<\/strong><\/h3>\n<p class=\"isSelectedEnd\">Le BLADE fonctionne gr\u00e2ce \u00e0 un syst\u00e8me int\u00e9gr\u00e9 <strong>\u00c9cran tactile haute d\u00e9finition de 10 pouces<\/strong> qui affiche toutes les conditions de fonctionnement, y compris les graphiques, sur un seul \u00e9cran.<\/p>\n<p class=\"isSelectedEnd\">Une cam\u00e9ra haute d\u00e9finition int\u00e9gr\u00e9e permet aux utilisateurs d'observer les processus de digestion en temps r\u00e9el pendant le fonctionnement. Le syst\u00e8me est \u00e9galement \u00e9quip\u00e9 d'un indicateur lumineux visuel (VLI), qui permet aux techniciens de d\u00e9terminer l'\u00e9tat du syst\u00e8me depuis n'importe quel endroit du laboratoire sans avoir \u00e0 surveiller l'appareil en permanence.<\/p>\n<h3 class=\"bold\"><strong>Contr\u00f4le et conformit\u00e9 au CFR<\/strong><\/h3>\n<p class=\"isSelectedEnd\">Le BLADE mesure, contr\u00f4le et enregistre en direct la temp\u00e9rature et la pression de chaque \u00e9chantillon tout au long du processus de digestion. Toutes les conditions de fonctionnement sont enregistr\u00e9es \u00e9lectroniquement et peuvent \u00eatre consult\u00e9es ult\u00e9rieurement \u00e0 des fins de v\u00e9rification, de documentation ou d'audit.<\/p>\n<p class=\"isSelectedEnd\">Pour les laboratoires exer\u00e7ant leurs activit\u00e9s dans le cadre de <strong>Exigences de la partie 11 du titre 21 du CFR,<\/strong> Le syst\u00e8me int\u00e8gre un mode CFR d\u00e9di\u00e9. Ce logiciel offre des fonctionnalit\u00e9s telles que le contr\u00f4le d'acc\u00e8s des utilisateurs, les pistes d'audit, les mots de passe, les signatures \u00e9lectroniques et d'autres fonctionnalit\u00e9s n\u00e9cessaires pour se conformer \u00e0 la norme 21 CFR Partie 11, sous-parties A \u00e0 C.<\/p>\n<h3><strong>Technologie de cavit\u00e9 monomode<\/strong><\/h3>\n<p class=\"isSelectedEnd\">Le BLADE utilise la technologie Single Mode Cavity\u2122 (SMC) de la soci\u00e9t\u00e9, qui ajuste automatiquement l'\u00e9nergie micro-ondes en fonction de chaque \u00e9chantillon et de sa matrice acide. En dirigeant une puissance micro-ondes optimis\u00e9e vers chaque \u00e9chantillon individuellement, le syst\u00e8me permet des digestions plus rapides, plus s\u00fbres et plus compl\u00e8tes, tout en garantissant des conditions de traitement constantes.<\/p>\n<h3><strong>D\u00e9termination pr\u00e9cise des m\u00e9taux traces dans les \u00e9chantillons alimentaires<\/strong><\/h3>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"wp-image-2330 alignright\" src=\"https:\/\/scispx.com\/wp-content\/uploads\/2022\/12\/eating-601581_1920-300x208.jpg\" alt=\"Digestion d&#039;\u00e9chantillons alimentaires\" width=\"308\" height=\"213\" srcset=\"https:\/\/scispx.com\/wp-content\/uploads\/2022\/12\/eating-601581_1920-300x208.jpg 300w, https:\/\/scispx.com\/wp-content\/uploads\/2022\/12\/eating-601581_1920-1024x710.jpg 1024w, https:\/\/scispx.com\/wp-content\/uploads\/2022\/12\/eating-601581_1920-768x532.jpg 768w, https:\/\/scispx.com\/wp-content\/uploads\/2022\/12\/eating-601581_1920-1536x1065.jpg 1536w, https:\/\/scispx.com\/wp-content\/uploads\/2022\/12\/eating-601581_1920-18x12.jpg 18w, https:\/\/scispx.com\/wp-content\/uploads\/2022\/12\/eating-601581_1920.jpg 1920w\" sizes=\"(max-width: 308px) 100vw, 308px\" \/><\/p>\n<p>Digestion d\u2019\u00e9chantillons alimentaires Une analyse pr\u00e9cise des m\u00e9taux traces est essentielle pour un \u00e9tiquetage fiable et la s\u00e9curit\u00e9 du consommateur. Gr\u00e2ce \u00e0 la combinaison d\u2019une cavit\u00e9 Single Mode et d\u2019un vortexing rapide, le syst\u00e8me BLADE dig\u00e8re rapidement et compl\u00e8tement m\u00eame les \u00e9chantillons alimentaires les plus exigeants, sans n\u00e9cessiter que les \u00e9chantillons soient similaires dans un m\u00eame lot. D\u00e9couvrez \u00e9galement la <a href=\"https:\/\/scispx.com\/wp-content\/uploads\/2023\/02\/ApNote_BLADE_Digestion_and_Analysis_of_Food_Samples.pdf\">note d\u2019application<\/a> pr\u00e9sentant la digestion et l\u2019analyse de diff\u00e9rents \u00e9chantillons alimentaires<\/p>\n<p>&nbsp;<\/p>\n<p><script type=\"application\/ld+json\">{\n    \"@context\": \"https:\\\/\\\/schema.org\",\n    \"@type\": \"FAQPage\",\n    \"mainEntity\": [\n        {\n            \"@type\": \"Question\",\n            \"name\": \"What is microwave digestion?\",\n            \"acceptedAnswer\": {\n                \"@type\": \"Answer\",\n                \"text\": \"Microwave digestion is a sample preparation technique that uses microwave energy, acids, and controlled pressure and temperature to dissolve samples before elemental analysis. It is commonly used before ICP-OES, ICP-MS, and atomic absorption spectroscopy.\"\n            }\n        },\n        {\n            \"@type\": \"Question\",\n            \"name\": \"Why is microwave digestion important for elemental analysis?\",\n            \"acceptedAnswer\": {\n                \"@type\": \"Answer\",\n                \"text\": \"Microwave digestion converts solid, liquid, and complex matrices into homogeneous solutions suitable for elemental analysis. Proper digestion improves analytical accuracy, reproducibility, and recovery of target elements.\"\n            }\n        },\n        {\n            \"@type\": \"Question\",\n            \"name\": \"What makes the BLADE different from traditional microwave digestion systems?\",\n            \"acceptedAnswer\": {\n                \"@type\": \"Answer\",\n                \"text\": \"The BLADE combines automated vessel loading, sealing, digestion, cooling, and unloading into a single workflow. Unlike conventional systems, it minimizes manual intervention and allows continuous sample processing while maintaining traceability.\"\n            }\n        },\n        {\n            \"@type\": \"Question\",\n            \"name\": \"Can the BLADE process multiple sample types in the same run?\",\n            \"acceptedAnswer\": {\n                \"@type\": \"Answer\",\n                \"text\": \"Yes. The system supports mix-and-match digestion, allowing different sample types and acid combinations to be processed within the same automated sequence. This reduces the need for separate digestion batches.\"\n            }\n        },\n        {\n            \"@type\": \"Question\",\n            \"name\": \"How does the BLADE increase laboratory throughput?\",\n            \"acceptedAnswer\": {\n                \"@type\": \"Answer\",\n                \"text\": \"The BLADE uses Single Mode Cavity technology and advanced vortexing to deliver high microwave energy directly to individual samples. This enables complete digestion cycles, including cooling, within minutes and allows faster sample turnaround.\"\n            }\n        },\n        {\n            \"@type\": \"Question\",\n            \"name\": \"Why are disposable caps beneficial in microwave digestion?\",\n            \"acceptedAnswer\": {\n                \"@type\": \"Answer\",\n                \"text\": \"Disposable caps eliminate the need to clean reusable vessel caps or seal plugs. This reduces preparation time, minimizes contamination risks, and increases laboratory efficiency.\"\n            }\n        },\n        {\n            \"@type\": \"Question\",\n            \"name\": \"Which sample types can be digested using the BLADE?\",\n            \"acceptedAnswer\": {\n                \"@type\": \"Answer\",\n                \"text\": \"The BLADE can digest a wide range of materials, including food samples, plant materials, petroleum products, bunker oil, plastics such as PET, catalysts, and other challenging industrial matrices.\"\n            }\n        },\n        {\n            \"@type\": \"Question\",\n            \"name\": \"Which acids can be used with the BLADE microwave digestion system?\",\n            \"acceptedAnswer\": {\n                \"@type\": \"Answer\",\n                \"text\": \"The system supports nitric acid (HNO\\u2083), hydrochloric acid (HCl), and hydrofluoric acid (HF), depending on the sample type and analytical requirements.\"\n            }\n        },\n        {\n            \"@type\": \"Question\",\n            \"name\": \"What are the advantages of automated microwave digestion?\",\n            \"acceptedAnswer\": {\n                \"@type\": \"Answer\",\n                \"text\": \"Automated microwave digestion increases throughput, improves reproducibility, reduces operator exposure to hazardous reagents, enhances traceability, and minimizes manual handling throughout the digestion workflow.\"\n            }\n        }\n    ]\n}<\/script><\/p>\n<p><script type=\"application\/ld+json\">{\n    \"@context\": \"https:\\\/\\\/schema.org\\\/\",\n    \"@type\": \"Product\",\n    \"name\": \"BLADE\",\n    \"image\": \"https:\\\/\\\/scispx.com\\\/wp-content\\\/uploads\\\/2022\\\/12\\\/blade_product_web.png\",\n    \"description\": \"The BLADE microwave digestion system simplifies elemental sample preparation while increasing laboratory throughput. By combining fast digestion, simplified vessel handling, automated workflows, and flexible sample processing, the system helps laboratories process a wide range of samples in less time without compromising performance or traceability.\",\n    \"brand\": {\n        \"@type\": \"Brand\",\n        \"name\": \"CEM\"\n    },\n    \"offers\": {\n        \"@type\": \"Offer\",\n        \"url\": \"https:\\\/\\\/scispx.com\\\/instruments\\\/blade\\\/\",\n        \"priceCurrency\": \"EUR\",\n        \"price\": \"0\",\n        \"availability\": \"https:\\\/\\\/schema.org\\\/InStock\",\n        \"seller\": {\n            \"@type\": \"Organization\",\n            \"name\": \"SciSPX\",\n            \"url\": \"https:\\\/\\\/scispx.com\",\n            \"logo\": \"https:\\\/\\\/scispx.com\\\/wp-content\\\/uploads\\\/2025\\\/04\\\/SciSPX_RGB-Icon.png\",\n            \"areaServed\": [\n                {\n                    \"@type\": \"Country\",\n                    \"name\": \"Belgium\"\n                },\n                {\n                    \"@type\": \"Country\",\n                    \"name\": \"Netherlands\"\n                },\n                {\n                    \"@type\": \"Country\",\n                    \"name\": \"Luxembourg\"\n                }\n            ]\n        }\n    }\n}<\/script><\/p>","protected":false},"excerpt":{"rendered":"<p>Con\u00e7u pour simplifier la pr\u00e9paration des \u00e9chantillons \u00e9l\u00e9mentaires tout en augmentant le rendement du laboratoire<\/p>","protected":false},"featured_media":1389,"template":"","brands":[130],"applications":[217],"markets":[18,48,439,14,22,38,25,43,26,411,17,16,47,15,27,39,44,110,28,30,443,40,33,36,46,23,32,35,31],"class_list":["post-1205","instruments","type-instruments","status-publish","has-post-thumbnail","hentry","brands-cem","applications-digestion","markets-agriculture","markets-animal-feed","markets-battery-production","markets-chemical-industry","markets-chemicals-chemicals","markets-coal-coke-biomass","markets-consumer-products","markets-crop-farming","markets-dairy","markets-energy-and-bio-fuels","markets-energy-and-sustainability","markets-environmental","markets-fertilizers-and-chemicals","markets-food-and-beverage","markets-fruit-and-vegetables","markets-liquid-fuels","markets-livestock","markets-materials","markets-meat","markets-oils-and-fats","markets-packaging","markets-refinery","markets-snacks","markets-soil-and-surface","markets-soil-and-water-conservation","markets-specialty-chemicals","markets-sugar-industry","markets-wastewater-treatment","markets-water-and-soft-drinks"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v25.5 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Blade | Microwave Digestion System | SciSPX Analysis simplified<\/title>\n<meta name=\"description\" content=\"BLADE microwave digestion system accelerates sample preparation for elemental analysis. It handles both routine and challenging sample types.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/scispx.com\/fr\/instruments\/blade\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Blade | Microwave Digestion System | SciSPX Analysis simplified\" \/>\n<meta property=\"og:description\" content=\"BLADE microwave digestion system accelerates sample preparation for elemental analysis. It handles both routine and challenging sample types.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/scispx.com\/fr\/instruments\/blade\/\" \/>\n<meta property=\"og:site_name\" content=\"SciSPX Analysis simplified\" \/>\n<meta property=\"article:modified_time\" content=\"2026-10-12T06:37:16+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/scispx.com\/wp-content\/uploads\/2022\/12\/blade_product_web.png\" \/>\n\t<meta property=\"og:image:width\" content=\"600\" \/>\n\t<meta property=\"og:image:height\" content=\"600\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Dur\u00e9e de lecture estim\u00e9e\" \/>\n\t<meta name=\"twitter:data1\" content=\"4 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/scispx.com\/fr\/instruments\/blade\/\",\"url\":\"https:\/\/scispx.com\/fr\/instruments\/blade\/\",\"name\":\"Blade | Microwave Digestion System | SciSPX Analysis simplified\",\"isPartOf\":{\"@id\":\"https:\/\/scispx.com\/fr\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/scispx.com\/fr\/instruments\/blade\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/scispx.com\/fr\/instruments\/blade\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/scispx.com\/wp-content\/uploads\/2022\/12\/blade_product_web.png\",\"datePublished\":\"2022-12-21T16:09:53+00:00\",\"dateModified\":\"2026-10-12T06:37:16+00:00\",\"description\":\"BLADE microwave digestion system accelerates sample preparation for elemental analysis. It handles both routine and challenging sample types.\",\"breadcrumb\":{\"@id\":\"https:\/\/scispx.com\/fr\/instruments\/blade\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/scispx.com\/fr\/instruments\/blade\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/scispx.com\/fr\/instruments\/blade\/#primaryimage\",\"url\":\"https:\/\/scispx.com\/wp-content\/uploads\/2022\/12\/blade_product_web.png\",\"contentUrl\":\"https:\/\/scispx.com\/wp-content\/uploads\/2022\/12\/blade_product_web.png\",\"width\":600,\"height\":600,\"caption\":\"Microwave Digestion System\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/scispx.com\/fr\/instruments\/blade\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/scispx.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Instruments\",\"item\":\"https:\/\/scispx.com\/instruments\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Blade\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/scispx.com\/fr\/#website\",\"url\":\"https:\/\/scispx.com\/fr\/\",\"name\":\"SciSPX Analysis simplified\",\"description\":\"SciSPX Analysis simplified\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/scispx.com\/fr\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Blade | Syst\u00e8me de digestion par micro-ondes | SciSPX : l'analyse simplifi\u00e9e","description":"Le syst\u00e8me de digestion par micro-ondes BLADE acc\u00e9l\u00e8re la pr\u00e9paration des \u00e9chantillons pour l'analyse \u00e9l\u00e9mentaire. Il prend en charge les types d'\u00e9chantillons de routine et les types d'\u00e9chantillons difficiles.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/scispx.com\/fr\/instruments\/blade\/","og_locale":"fr_FR","og_type":"article","og_title":"Blade | Microwave Digestion System | SciSPX Analysis simplified","og_description":"BLADE microwave digestion system accelerates sample preparation for elemental analysis. It handles both routine and challenging sample types.","og_url":"https:\/\/scispx.com\/fr\/instruments\/blade\/","og_site_name":"SciSPX Analysis simplified","article_modified_time":"2026-10-12T06:37:16+00:00","og_image":[{"width":600,"height":600,"url":"https:\/\/scispx.com\/wp-content\/uploads\/2022\/12\/blade_product_web.png","type":"image\/png"}],"twitter_card":"summary_large_image","twitter_misc":{"Dur\u00e9e de lecture estim\u00e9e":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/scispx.com\/fr\/instruments\/blade\/","url":"https:\/\/scispx.com\/fr\/instruments\/blade\/","name":"Blade | Syst\u00e8me de digestion par micro-ondes | SciSPX : l'analyse simplifi\u00e9e","isPartOf":{"@id":"https:\/\/scispx.com\/fr\/#website"},"primaryImageOfPage":{"@id":"https:\/\/scispx.com\/fr\/instruments\/blade\/#primaryimage"},"image":{"@id":"https:\/\/scispx.com\/fr\/instruments\/blade\/#primaryimage"},"thumbnailUrl":"https:\/\/scispx.com\/wp-content\/uploads\/2022\/12\/blade_product_web.png","datePublished":"2022-12-21T16:09:53+00:00","dateModified":"2026-10-12T06:37:16+00:00","description":"Le syst\u00e8me de digestion par micro-ondes BLADE acc\u00e9l\u00e8re la pr\u00e9paration des \u00e9chantillons pour l'analyse \u00e9l\u00e9mentaire. Il prend en charge les types d'\u00e9chantillons de routine et les types d'\u00e9chantillons difficiles.","breadcrumb":{"@id":"https:\/\/scispx.com\/fr\/instruments\/blade\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/scispx.com\/fr\/instruments\/blade\/"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/scispx.com\/fr\/instruments\/blade\/#primaryimage","url":"https:\/\/scispx.com\/wp-content\/uploads\/2022\/12\/blade_product_web.png","contentUrl":"https:\/\/scispx.com\/wp-content\/uploads\/2022\/12\/blade_product_web.png","width":600,"height":600,"caption":"Microwave Digestion System"},{"@type":"BreadcrumbList","@id":"https:\/\/scispx.com\/fr\/instruments\/blade\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/scispx.com\/"},{"@type":"ListItem","position":2,"name":"Instruments","item":"https:\/\/scispx.com\/instruments\/"},{"@type":"ListItem","position":3,"name":"Blade"}]},{"@type":"WebSite","@id":"https:\/\/scispx.com\/fr\/#website","url":"https:\/\/scispx.com\/fr\/","name":"SciSPX Analyse simplifi\u00e9e","description":"SciSPX Analyse simplifi\u00e9e","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/scispx.com\/fr\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"}]}},"_links":{"self":[{"href":"https:\/\/scispx.com\/fr\/wp-json\/wp\/v2\/instruments\/1205","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/scispx.com\/fr\/wp-json\/wp\/v2\/instruments"}],"about":[{"href":"https:\/\/scispx.com\/fr\/wp-json\/wp\/v2\/types\/instruments"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/scispx.com\/fr\/wp-json\/wp\/v2\/media\/1389"}],"wp:attachment":[{"href":"https:\/\/scispx.com\/fr\/wp-json\/wp\/v2\/media?parent=1205"}],"wp:term":[{"taxonomy":"brands","embeddable":true,"href":"https:\/\/scispx.com\/fr\/wp-json\/wp\/v2\/brands?post=1205"},{"taxonomy":"applications","embeddable":true,"href":"https:\/\/scispx.com\/fr\/wp-json\/wp\/v2\/applications?post=1205"},{"taxonomy":"markets","embeddable":true,"href":"https:\/\/scispx.com\/fr\/wp-json\/wp\/v2\/markets?post=1205"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}