{"id":1198,"date":"2022-12-21T17:09:53","date_gmt":"2022-12-21T16:09:53","guid":{"rendered":"https:\/\/scispx.com\/instruments\/mars-6-extraction\/"},"modified":"2025-11-04T14:30:52","modified_gmt":"2025-11-04T12:30:52","slug":"mars-6-systeme-dextraction-par-micro-ondes","status":"publish","type":"instruments","link":"https:\/\/scispx.com\/fr\/instruments\/mars-6-extraction\/","title":{"rendered":"MARS 6 Extraction"},"content":{"rendered":"<h2 class=\"ml-0 mb-1 pl-0\">Microwave extraction system<\/h2>\n<p>Le MARS 6 Extraction\u2122 est un syst\u00e8me d\u2019extraction par micro-ondes qui allie design intelligent et facilit\u00e9 d\u2019utilisation exceptionnelle.\nAvec une puissance leader sur le march\u00e9 de 2000 watts, il est id\u00e9al pour pr\u00e9parer des \u00e9chantillons selon la norme <strong>m\u00e9thode EPA 3546<\/strong>les polym\u00e8res et bien plus encore.\nLe MARS 6 Extraction peut traiter jusqu\u2019\u00e0 <strong>40 \u00e9chantillons en un seul lot,<\/strong>en utilisant jusqu\u2019\u00e0 <strong>85% de solvant<\/strong> en moins par rapport aux m\u00e9thodes traditionnelles.\nIl offre le d\u00e9bit le plus \u00e9lev\u00e9 et le co\u00fbt par test le plus bas de toutes les m\u00e9thodes d\u2019extraction disponibles aujourd\u2019hui.<\/p>\n<p>&nbsp;<\/p>\n<h3><strong>Caract\u00e9ristiques du syst\u00e8me d'extraction par micro-ondes :<\/strong><\/h3>\n<ul>\n<li>Extraction de 40 \u00e9chantillons en seulement 25 minutes<\/li>\n<li>R\u00e9duction de solvant de 95 % par rapport \u00e0 la m\u00e9thode Soxhlet<\/li>\n<li>Capteurs avanc\u00e9s d\u00e9tectent les r\u00e9cipients et ajustent la puissance en cons\u00e9quence<\/li>\n<li>Conception flexible et ouverte permettant l\u2019utilisation de diff\u00e9rents types de r\u00e9cipients<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<h3><strong>Fonctionnement<\/strong><\/h3>\n<p><strong>Gagnez du temps et r\u00e9duisez vos co\u00fbts gr\u00e2ce \u00e0 l\u2019extraction par micro-ondes<\/strong><br \/>\nGagnez du temps et r\u00e9duisez vos co\u00fbts gr\u00e2ce \u00e0 l\u2019extraction par micro-ondes.\nLe MARS 6 peut pr\u00e9parer jusqu\u2019\u00e0 40 \u00e9chantillons en un seul lot en 25 minutes, offrant ainsi le d\u00e9bit le plus \u00e9lev\u00e9 et le co\u00fbt par test le plus bas du march\u00e9.\nLe contr\u00f4le de temp\u00e9rature pour chaque r\u00e9cipient et les technologies brevet\u00e9es PowerMAX garantissent une pr\u00e9cision in\u00e9gal\u00e9e en mati\u00e8re de mesure et de r\u00e9gulation, tandis que la technologie exclusive One Touch assure une facilit\u00e9 d\u2019utilisation exceptionnelle.<\/p>\n<p><strong>Technologie One-Touch<\/strong><br \/>\n<strong>Des m\u00e9thodes pr\u00e9install\u00e9es, \u00e0 port\u00e9e de main<\/strong><br \/>\nEn appuyant sur l\u2019ic\u00f4ne One-Touch sur l\u2019\u00e9cran tactile du MARS 6, vous s\u00e9lectionnez simplement le type d\u2019\u00e9chantillon parmi les nombreuses m\u00e9thodes pr\u00e9install\u00e9es. Le syst\u00e8me fait ensuite le reste : il d\u00e9tecte automatiquement le type de r\u00e9cipient, compte le nombre d\u2019\u00e9chantillons, ajuste la puissance en cons\u00e9quence, puis lance l\u2019extraction. C\u2019est aussi simple que cela !<\/p>\n<p>&nbsp;<\/p>\n<h3><strong>R\u00e9cipients<\/strong><\/h3>\n<p><strong>Des r\u00e9cipients con\u00e7us pour vous.<\/strong><\/p>\n<p><strong>Le r\u00e9cipient MARSXpress<\/strong><br \/>\nLe r\u00e9cipient MARSXpress de 75 ml est parfaitement adapt\u00e9 \u00e0 la m\u00e9thode USEPA 3546, permettant l\u2019extraction d\u2019\u00e9chantillons jusqu\u2019\u00e0 20 grammes. Sa conception simple en trois pi\u00e8ces le rend particuli\u00e8rement facile \u00e0 manipuler. Capable de traiter jusqu\u2019\u00e0 40 \u00e9chantillons simultan\u00e9ment, il offre aux laboratoires un d\u00e9bit \u00e9lev\u00e9 et le co\u00fbt par test le plus bas parmi tous les syst\u00e8mes disponibles sur le march\u00e9.<\/p>\n<p>&nbsp;<\/p>\n<p><strong>Le r\u00e9cipient MARSXpress Plus avec doublure en verre en option<\/strong><br \/>\nLe r\u00e9cipient MARSXpress de 110 ml offre un grand volume, id\u00e9al pour le traitement d\u2019\u00e9chantillons jusqu\u2019\u00e0 30 grammes. Il peut \u00eatre utilis\u00e9 avec un rev\u00eatement en verre jetable pratique, \u00e9liminant ainsi les \u00e9tapes de lavage entre les s\u00e9ries. Ce rev\u00eatement prot\u00e8ge \u00e9galement le r\u00e9cipient en T\u00e9flon\u00ae contre les contaminants fortement concentr\u00e9s.<\/p>","protected":false},"excerpt":{"rendered":"<p>Le MARS 6\u2122 Extraction offre un design intelligent et une facilit\u00e9 d\u2019utilisation remarquable pour les extractions<\/p>","protected":false},"featured_media":3886,"template":"","brands":[130],"applications":[220],"markets":[18,45,14,25,43,16,34,36],"class_list":["post-1198","instruments","type-instruments","status-publish","has-post-thumbnail","hentry","brands-cem","applications-extraction","markets-agriculture","markets-agriculture-analysis-services","markets-chemical-industry","markets-consumer-products","markets-crop-farming","markets-environmental","markets-environmental-services-and-equipment","markets-soil-and-surface"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v25.5 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>MARS 6 Extraction | Microwave Extraction System | SciSPX Analysis simplified<\/title>\n<meta name=\"description\" content=\"This microwave extraction system can process up to 40 samples in a single batch, using up to 85% less solvent than traditional methods.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/scispx.com\/fr\/instruments\/mars-6-extraction\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"MARS 6 Extraction | Microwave Extraction System | SciSPX Analysis simplified\" \/>\n<meta property=\"og:description\" content=\"This microwave extraction system can process up to 40 samples in a single batch, using up to 85% less solvent than traditional methods.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/scispx.com\/fr\/instruments\/mars-6-extraction\/\" \/>\n<meta property=\"og:site_name\" content=\"SciSPX Analysis simplified\" \/>\n<meta property=\"article:modified_time\" content=\"2025-11-04T12:30:52+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/scispx.com\/wp-content\/uploads\/2022\/12\/mars-6-exctraction.png\" \/>\n\t<meta property=\"og:image:width\" content=\"495\" \/>\n\t<meta property=\"og:image:height\" content=\"527\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Dur\u00e9e de lecture estim\u00e9e\" \/>\n\t<meta name=\"twitter:data1\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/scispx.com\/fr\/instruments\/mars-6-extraction\/\",\"url\":\"https:\/\/scispx.com\/fr\/instruments\/mars-6-extraction\/\",\"name\":\"MARS 6 Extraction | Microwave Extraction System | SciSPX Analysis simplified\",\"isPartOf\":{\"@id\":\"https:\/\/scispx.com\/fr\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/scispx.com\/fr\/instruments\/mars-6-extraction\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/scispx.com\/fr\/instruments\/mars-6-extraction\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/scispx.com\/wp-content\/uploads\/2022\/12\/mars-6-exctraction.png\",\"datePublished\":\"2022-12-21T16:09:53+00:00\",\"dateModified\":\"2025-11-04T12:30:52+00:00\",\"description\":\"This microwave extraction system can process up to 40 samples in a single batch, using up to 85% less solvent than traditional methods.\",\"breadcrumb\":{\"@id\":\"https:\/\/scispx.com\/fr\/instruments\/mars-6-extraction\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/scispx.com\/fr\/instruments\/mars-6-extraction\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/scispx.com\/fr\/instruments\/mars-6-extraction\/#primaryimage\",\"url\":\"https:\/\/scispx.com\/wp-content\/uploads\/2022\/12\/mars-6-exctraction.png\",\"contentUrl\":\"https:\/\/scispx.com\/wp-content\/uploads\/2022\/12\/mars-6-exctraction.png\",\"width\":495,\"height\":527,\"caption\":\"Microwave extraction system\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/scispx.com\/fr\/instruments\/mars-6-extraction\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/scispx.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Instruments\",\"item\":\"https:\/\/scispx.com\/instruments\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"MARS 6 Extraction\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/scispx.com\/fr\/#website\",\"url\":\"https:\/\/scispx.com\/fr\/\",\"name\":\"SciSPX Analysis simplified\",\"description\":\"SciSPX Analysis simplified\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/scispx.com\/fr\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Extraction MARS 6 | Syst\u00e8me d'extraction par micro-ondes | SciSPX : l'analyse simplifi\u00e9e","description":"Ce syst\u00e8me d'extraction par micro-ondes peut traiter jusqu'\u00e0 40 \u00e9chantillons en un seul lot, en utilisant jusqu'\u00e0 85% de solvant en moins.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/scispx.com\/fr\/instruments\/mars-6-extraction\/","og_locale":"fr_FR","og_type":"article","og_title":"MARS 6 Extraction | Microwave Extraction System | SciSPX Analysis simplified","og_description":"This microwave extraction system can process up to 40 samples in a single batch, using up to 85% less solvent than traditional methods.","og_url":"https:\/\/scispx.com\/fr\/instruments\/mars-6-extraction\/","og_site_name":"SciSPX Analysis simplified","article_modified_time":"2025-11-04T12:30:52+00:00","og_image":[{"width":495,"height":527,"url":"https:\/\/scispx.com\/wp-content\/uploads\/2022\/12\/mars-6-exctraction.png","type":"image\/png"}],"twitter_card":"summary_large_image","twitter_misc":{"Dur\u00e9e de lecture estim\u00e9e":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/scispx.com\/fr\/instruments\/mars-6-extraction\/","url":"https:\/\/scispx.com\/fr\/instruments\/mars-6-extraction\/","name":"Extraction MARS 6 | Syst\u00e8me d'extraction par micro-ondes | SciSPX : l'analyse simplifi\u00e9e","isPartOf":{"@id":"https:\/\/scispx.com\/fr\/#website"},"primaryImageOfPage":{"@id":"https:\/\/scispx.com\/fr\/instruments\/mars-6-extraction\/#primaryimage"},"image":{"@id":"https:\/\/scispx.com\/fr\/instruments\/mars-6-extraction\/#primaryimage"},"thumbnailUrl":"https:\/\/scispx.com\/wp-content\/uploads\/2022\/12\/mars-6-exctraction.png","datePublished":"2022-12-21T16:09:53+00:00","dateModified":"2025-11-04T12:30:52+00:00","description":"Ce syst\u00e8me d'extraction par micro-ondes peut traiter jusqu'\u00e0 40 \u00e9chantillons en un seul lot, en utilisant jusqu'\u00e0 85% de solvant en moins.","breadcrumb":{"@id":"https:\/\/scispx.com\/fr\/instruments\/mars-6-extraction\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/scispx.com\/fr\/instruments\/mars-6-extraction\/"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/scispx.com\/fr\/instruments\/mars-6-extraction\/#primaryimage","url":"https:\/\/scispx.com\/wp-content\/uploads\/2022\/12\/mars-6-exctraction.png","contentUrl":"https:\/\/scispx.com\/wp-content\/uploads\/2022\/12\/mars-6-exctraction.png","width":495,"height":527,"caption":"Microwave extraction system"},{"@type":"BreadcrumbList","@id":"https:\/\/scispx.com\/fr\/instruments\/mars-6-extraction\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/scispx.com\/"},{"@type":"ListItem","position":2,"name":"Instruments","item":"https:\/\/scispx.com\/instruments\/"},{"@type":"ListItem","position":3,"name":"MARS 6 Extraction"}]},{"@type":"WebSite","@id":"https:\/\/scispx.com\/fr\/#website","url":"https:\/\/scispx.com\/fr\/","name":"SciSPX Analyse simplifi\u00e9e","description":"SciSPX Analyse simplifi\u00e9e","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/scispx.com\/fr\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"}]}},"_links":{"self":[{"href":"https:\/\/scispx.com\/fr\/wp-json\/wp\/v2\/instruments\/1198","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/scispx.com\/fr\/wp-json\/wp\/v2\/instruments"}],"about":[{"href":"https:\/\/scispx.com\/fr\/wp-json\/wp\/v2\/types\/instruments"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/scispx.com\/fr\/wp-json\/wp\/v2\/media\/3886"}],"wp:attachment":[{"href":"https:\/\/scispx.com\/fr\/wp-json\/wp\/v2\/media?parent=1198"}],"wp:term":[{"taxonomy":"brands","embeddable":true,"href":"https:\/\/scispx.com\/fr\/wp-json\/wp\/v2\/brands?post=1198"},{"taxonomy":"applications","embeddable":true,"href":"https:\/\/scispx.com\/fr\/wp-json\/wp\/v2\/applications?post=1198"},{"taxonomy":"markets","embeddable":true,"href":"https:\/\/scispx.com\/fr\/wp-json\/wp\/v2\/markets?post=1198"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}