{"id":1192,"date":"2022-12-21T17:09:53","date_gmt":"2022-12-21T16:09:53","guid":{"rendered":"https:\/\/scispx.com\/instruments\/varidens\/"},"modified":"2025-11-24T16:23:12","modified_gmt":"2025-11-24T14:23:12","slug":"varidens-densimetre-de-paillasse","status":"publish","type":"instruments","link":"https:\/\/scispx.com\/fr\/instruments\/varidens\/","title":{"rendered":"VariDens"},"content":{"rendered":"<h2>Densim\u00e8tre de paillasse<\/h2>\n<p>Ce densim\u00e8tre compact de paillasse de SCHMIDT + HAENSCH allie design \u00e9l\u00e9gant et performance. Il fournit des mesures pr\u00e9cises et fiables gr\u00e2ce au principe \u00e9prouv\u00e9 du tube en U oscillant. Id\u00e9al pour l\u2019analyse de la densit\u00e9 et de la concentration de produits pharmaceutiques, chimiques et photochimiques.<\/p>\n<p>Ce densim\u00e8tre renforce la technologie \u00e9prouv\u00e9e de SCHMIDT + HAENSCH en l\u2019int\u00e9grant \u00e0 des fonctionnalit\u00e9s innovantes issues de la gamme avanc\u00e9e VariFamily :\u00a0<a href=\"https:\/\/scispx.com\/fr\/instruments\/varipol-series\/\" target=\"_blank\" rel=\"noopener\">S\u00e9rie VariPol<\/a> et\u00a0<a href=\"https:\/\/scispx.com\/fr\/instruments\/variref\/\" target=\"_blank\" rel=\"noopener\">VariRef<\/a><\/p>\n<p>&nbsp;<\/p>\n<h3><strong>Caract\u00e9ristiques du densim\u00e8tre de paillasse :\u00a0<\/strong><\/h3>\n<ul>\n<li>Utilisation modulaire, connectable \u00e0 votre navigateur Internet, tablette ou appareil de votre choix<\/li>\n<li>Interface utilisateur intuitive, adapt\u00e9e \u00e0 plusieurs utilisateurs<\/li>\n<li>Contr\u00f4le rapide de la temp\u00e9rature<\/li>\n<li>Facile \u00e0 nettoyer<\/li>\n<li>Sans maintenance<\/li>\n<li>Conforme \u00e0 la norme 21 CFR Part 11<\/li>\n<li>Compatible ELN\/LIMS<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<h3><strong>Applications\u00a0<\/strong><\/h3>\n<p>SCHMIDT + HAENSCH fournit des solutions fiables de mesure de densit\u00e9 et de concentration pour un large \u00e9ventail d\u2019industries, notamment l\u2019agroalimentaire, la pharmacie, la chimie, les cosm\u00e9tiques, la p\u00e9trochimie, et bien plus encore.<\/p>\n<p>En commandant la version \u00ab pharma-ready \u00bb du VariDens, vous recevez toute la documentation, les fonctionnalit\u00e9s et les m\u00e9thodes n\u00e9cessaires pour garantir la conformit\u00e9 \u00e0 la norme 21 CFR Part 11. Avec plusieurs tables de r\u00e9f\u00e9rence pour l\u2019alcool, une r\u00e9solution de densit\u00e9 haute pr\u00e9cision, une connectivit\u00e9 USB et Ethernet, une sortie s\u00e9rie et une large gamme d\u2019accessoires, il est con\u00e7u pour r\u00e9pondre aux applications les plus exigeantes.<\/p>\n<p>&nbsp;<\/p>\n<h3><strong>Le produit en d\u00e9tail\u00a0<\/strong><\/h3>\n<p>Le densim\u00e8tre propose en option des capteurs d\u2019humidit\u00e9 et de pression atmosph\u00e9rique, tandis que ses programmes de r\u00e9gulation de temp\u00e9rature tr\u00e8s pr\u00e9cis garantissent des performances fiables, m\u00eame dans des conditions environnementales difficiles.<\/p>\n<p>Le logiciel intuitif et convivial, associ\u00e9 \u00e0 un grand \u00e9cran tactile couleur TFT, r\u00e9duit les temps de configuration et offre de puissantes capacit\u00e9s de diagnostic. Les accessoires standard et les raccords robustes et interchangeables r\u00e9duisent les co\u00fbts d\u2019installation et font gagner du temps lors de l\u2019\u00e9valuation de produits tiers.<\/p>\n<p>&nbsp;<\/p>\n<h3><strong>Sp\u00e9cifications du densim\u00e8tre de table<\/strong><\/h3>\n<div class=\"elementor-element elementor-element-6836d8d elementor-widget elementor-widget-text-editor\" data-id=\"6836d8d\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n<div class=\"elementor-widget-container\">\n<table style=\"height: 932px;\" width=\"770\">\n<tbody>\n<tr>\n<td width=\"193\"><\/td>\n<td width=\"193\"><strong>VariDens C<\/strong><\/td>\n<td width=\"193\"><strong>VariDens B<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"193\"><strong>Plage de mesure<\/strong><\/td>\n<td colspan=\"2\" width=\"387\">0 - 3 g\/cm3<\/td>\n<\/tr>\n<tr>\n<td width=\"193\"><strong>Plage de temp\u00e9rature<\/strong><\/td>\n<td colspan=\"2\" width=\"387\">10 - 95\u00b0C* (thermo\u00e9l\u00e9ment Peltier r\u00e9gul\u00e9)<\/td>\n<\/tr>\n<tr>\n<td width=\"193\"><strong>Gamme de pression<\/strong><\/td>\n<td colspan=\"2\" width=\"387\">0 \u00e0 10 Bar (0 \u00e0 145 psi)<\/td>\n<\/tr>\n<tr>\n<td width=\"193\"><strong>Pr\u00e9cision de la densit\u00e9<\/strong><\/td>\n<td width=\"193\">\u00b1 0,0001 g\/cm3<\/td>\n<td width=\"193\">\u00b1 0,00005 g\/cm3<\/td>\n<\/tr>\n<tr>\n<td width=\"193\"><strong>Reproductibilit\u00e9<\/strong><\/td>\n<td width=\"193\">\u00b1 0,0001 g\/cm3<\/td>\n<td width=\"193\">\u00b1 0,00002 g\/cm3<\/td>\n<\/tr>\n<tr>\n<td width=\"193\"><strong>R\u00e9solution<\/strong><\/td>\n<td width=\"193\">\u00a0 \u00a00,0001 g\/cm3<\/td>\n<td width=\"193\">\u00a0 \u00a00,00001 g\/cm3<\/td>\n<\/tr>\n<tr>\n<td width=\"193\"><strong>Pr\u00e9cision de la temp\u00e9rature<\/strong><\/td>\n<td width=\"193\">\u00b1 0.05 \u00b0C<\/td>\n<td width=\"193\">\u00b1 0.03 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td width=\"193\"><strong>Reproductibilit\u00e9<\/strong><\/td>\n<td width=\"193\">\u00b1 0.02 \u00b0C<\/td>\n<td width=\"193\">\u00b1 0.01 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td width=\"193\"><strong>R\u00e9solution<\/strong><\/td>\n<td width=\"193\">\u00a0 \u00a00.01 \u00b0C<\/td>\n<td width=\"193\">\u00a0 \u00a00.01 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td width=\"193\"><strong>Temps de stabilisation thermique<\/strong><\/td>\n<td colspan=\"2\" width=\"387\">25 \u00b0C \u00e0 20 \u00b0C, \u00b1 0,01 \u00b0C en 18 minutes*<\/td>\n<\/tr>\n<tr>\n<td width=\"193\"><strong>Parties en contact avec le produit<\/strong><\/td>\n<td colspan=\"2\" width=\"387\">Verre borosilicat\u00e9, PTFE<\/td>\n<\/tr>\n<tr>\n<td width=\"193\"><strong>D\u00e9tection des bulles<\/strong><\/td>\n<td colspan=\"2\" width=\"387\">Oui (combin\u00e9 : visuel-\u00e9lectronique)<\/td>\n<\/tr>\n<tr>\n<td width=\"193\"><strong>S\u00e9chage<\/strong><\/td>\n<td colspan=\"2\" width=\"387\">Pompe \u00e0 air int\u00e9gr\u00e9e<\/td>\n<\/tr>\n<tr>\n<td width=\"193\"><strong>Compensation de la temp\u00e9rature<\/strong><\/td>\n<td colspan=\"2\" width=\"387\">Oui<\/td>\n<\/tr>\n<tr>\n<td width=\"193\"><strong>Volume minimal de l'\u00e9chantillon<\/strong><\/td>\n<td colspan=\"2\" width=\"387\">1,5 ml<\/td>\n<\/tr>\n<tr>\n<td width=\"193\"><strong>Temps de mesure par \u00e9chantillon**<\/strong><\/td>\n<td width=\"193\">&lt; 10 sec<\/td>\n<td width=\"193\">&lt; 30 sec<\/td>\n<\/tr>\n<tr>\n<td width=\"193\"><strong>Affichage<\/strong><\/td>\n<td colspan=\"2\" width=\"387\">\u00c9cran tactile de 7\u2033***, 800 x 480 pixels<\/td>\n<\/tr>\n<tr>\n<td width=\"193\"><strong>Interfaces<\/strong><\/td>\n<td colspan=\"2\" width=\"387\">Ethernet 10\/100\/1000, RS232, USB, WLAN***<\/td>\n<\/tr>\n<tr>\n<td width=\"193\"><strong>Conditions ambiantes<\/strong><\/td>\n<td colspan=\"2\" width=\"387\">Temp\u00e9rature 10 \u00b0C \u00e0 35 \u00b0C, Humidit\u00e9 &lt; 85 % sans condensation<\/td>\n<\/tr>\n<tr>\n<td width=\"193\"><strong>Puissance<\/strong><\/td>\n<td colspan=\"2\" width=\"387\">VAC 90-265 ; 50\/60 Hz ; 150 W max<\/td>\n<\/tr>\n<tr>\n<td width=\"193\"><strong>Conformit\u00e9<\/strong><\/td>\n<td colspan=\"2\" width=\"387\">Pharmacop\u00e9e internationale, ASTM, AOAC, DIN, 21 CFR part 11, ICUMSA et autres<\/td>\n<\/tr>\n<tr>\n<td width=\"193\"><strong>Dimensions<\/strong><\/td>\n<td colspan=\"2\" width=\"387\">Avec \u00e9cran : 430 x 300 x 235 mm (l x p x h) \/ sans \u00e9cran : 430 x 300 x 150 mm (l x p x h)<\/td>\n<\/tr>\n<tr>\n<td width=\"193\"><strong>Points forts<\/strong><\/td>\n<td colspan=\"2\" width=\"387\">Modularit\u00e9, convivialit\u00e9, contr\u00f4le rapide de la temp\u00e9rature, nettoyage facile, produit ne n\u00e9cessitant pratiquement pas d'entretien,<br \/>\nConformit\u00e9 \u00e0 la norme 21 CFR part 11 ; ELN ; pr\u00eat pour LIMS<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>* Valable pour une temp\u00e9rature ambiante de 20 \u00b0C<br \/>\n** Apr\u00e8s stabilisation de la temp\u00e9rature<br \/>\n*** Facultatif<\/p>\n<\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Mesure de la densit\u00e9 et de la concentration<\/p>","protected":false},"featured_media":1315,"template":"","brands":[266],"applications":[237],"markets":[22,26,17,16,34,15,27,39,110,30,116,117,40,33,23,32,31],"class_list":["post-1192","instruments","type-instruments","status-publish","has-post-thumbnail","hentry","brands-schmidt-_haensch","applications-density-meter","markets-chemicals-chemicals","markets-dairy","markets-energy-and-sustainability","markets-environmental","markets-environmental-services-and-equipment","markets-food-and-beverage","markets-fruit-and-vegetables","markets-liquid-fuels","markets-materials","markets-oils-and-fats","markets-paper-packaging-products","markets-polymers-rubber","markets-refinery","markets-snacks","markets-specialty-chemicals","markets-sugar-industry","markets-water-and-soft-drinks"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v25.5 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>VariDens | Benchtop Density Meter | SciSPX Analysis simplified<\/title>\n<meta name=\"description\" content=\"Benchtop density meter that delivers precise, reliable measurements using the proven oscillating U-tube principle.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/scispx.com\/fr\/instruments\/varidens\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"VariDens | Benchtop Density Meter | SciSPX Analysis simplified\" \/>\n<meta property=\"og:description\" content=\"Benchtop density meter that delivers precise, reliable measurements using the proven oscillating U-tube principle.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/scispx.com\/fr\/instruments\/varidens\/\" \/>\n<meta property=\"og:site_name\" content=\"SciSPX Analysis simplified\" \/>\n<meta property=\"article:modified_time\" content=\"2025-11-24T14:23:12+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/scispx.com\/wp-content\/uploads\/2022\/12\/varidens_density_free-2048x1260-1.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"2048\" \/>\n\t<meta property=\"og:image:height\" content=\"1260\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Dur\u00e9e de lecture estim\u00e9e\" \/>\n\t<meta name=\"twitter:data1\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/scispx.com\/fr\/instruments\/varidens\/\",\"url\":\"https:\/\/scispx.com\/fr\/instruments\/varidens\/\",\"name\":\"VariDens | Benchtop Density Meter | SciSPX Analysis simplified\",\"isPartOf\":{\"@id\":\"https:\/\/scispx.com\/fr\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/scispx.com\/fr\/instruments\/varidens\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/scispx.com\/fr\/instruments\/varidens\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/scispx.com\/wp-content\/uploads\/2022\/12\/varidens_density_free-2048x1260-1.jpg\",\"datePublished\":\"2022-12-21T16:09:53+00:00\",\"dateModified\":\"2025-11-24T14:23:12+00:00\",\"description\":\"Benchtop density meter that delivers precise, reliable measurements using the proven oscillating U-tube principle.\",\"breadcrumb\":{\"@id\":\"https:\/\/scispx.com\/fr\/instruments\/varidens\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/scispx.com\/fr\/instruments\/varidens\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/scispx.com\/fr\/instruments\/varidens\/#primaryimage\",\"url\":\"https:\/\/scispx.com\/wp-content\/uploads\/2022\/12\/varidens_density_free-2048x1260-1.jpg\",\"contentUrl\":\"https:\/\/scispx.com\/wp-content\/uploads\/2022\/12\/varidens_density_free-2048x1260-1.jpg\",\"width\":2048,\"height\":1260,\"caption\":\"benchtop density meter\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/scispx.com\/fr\/instruments\/varidens\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/scispx.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Instruments\",\"item\":\"https:\/\/scispx.com\/instruments\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"VariDens\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/scispx.com\/fr\/#website\",\"url\":\"https:\/\/scispx.com\/fr\/\",\"name\":\"SciSPX Analysis simplified\",\"description\":\"SciSPX Analysis simplified\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/scispx.com\/fr\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"VariDens | Densim\u00e8tre de paillasse | SciSPX : l'analyse simplifi\u00e9e","description":"Densim\u00e8tre de paillasse offrant des mesures pr\u00e9cises et fiables gr\u00e2ce au principe \u00e9prouv\u00e9 du tube en U oscillant.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/scispx.com\/fr\/instruments\/varidens\/","og_locale":"fr_FR","og_type":"article","og_title":"VariDens | Benchtop Density Meter | SciSPX Analysis simplified","og_description":"Benchtop density meter that delivers precise, reliable measurements using the proven oscillating U-tube principle.","og_url":"https:\/\/scispx.com\/fr\/instruments\/varidens\/","og_site_name":"SciSPX Analysis simplified","article_modified_time":"2025-11-24T14:23:12+00:00","og_image":[{"width":2048,"height":1260,"url":"https:\/\/scispx.com\/wp-content\/uploads\/2022\/12\/varidens_density_free-2048x1260-1.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Dur\u00e9e de lecture estim\u00e9e":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/scispx.com\/fr\/instruments\/varidens\/","url":"https:\/\/scispx.com\/fr\/instruments\/varidens\/","name":"VariDens | Densim\u00e8tre de paillasse | SciSPX : l'analyse simplifi\u00e9e","isPartOf":{"@id":"https:\/\/scispx.com\/fr\/#website"},"primaryImageOfPage":{"@id":"https:\/\/scispx.com\/fr\/instruments\/varidens\/#primaryimage"},"image":{"@id":"https:\/\/scispx.com\/fr\/instruments\/varidens\/#primaryimage"},"thumbnailUrl":"https:\/\/scispx.com\/wp-content\/uploads\/2022\/12\/varidens_density_free-2048x1260-1.jpg","datePublished":"2022-12-21T16:09:53+00:00","dateModified":"2025-11-24T14:23:12+00:00","description":"Densim\u00e8tre de paillasse offrant des mesures pr\u00e9cises et fiables gr\u00e2ce au principe \u00e9prouv\u00e9 du tube en U oscillant.","breadcrumb":{"@id":"https:\/\/scispx.com\/fr\/instruments\/varidens\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/scispx.com\/fr\/instruments\/varidens\/"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/scispx.com\/fr\/instruments\/varidens\/#primaryimage","url":"https:\/\/scispx.com\/wp-content\/uploads\/2022\/12\/varidens_density_free-2048x1260-1.jpg","contentUrl":"https:\/\/scispx.com\/wp-content\/uploads\/2022\/12\/varidens_density_free-2048x1260-1.jpg","width":2048,"height":1260,"caption":"benchtop density meter"},{"@type":"BreadcrumbList","@id":"https:\/\/scispx.com\/fr\/instruments\/varidens\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/scispx.com\/"},{"@type":"ListItem","position":2,"name":"Instruments","item":"https:\/\/scispx.com\/instruments\/"},{"@type":"ListItem","position":3,"name":"VariDens"}]},{"@type":"WebSite","@id":"https:\/\/scispx.com\/fr\/#website","url":"https:\/\/scispx.com\/fr\/","name":"SciSPX Analyse simplifi\u00e9e","description":"SciSPX Analyse simplifi\u00e9e","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/scispx.com\/fr\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"}]}},"_links":{"self":[{"href":"https:\/\/scispx.com\/fr\/wp-json\/wp\/v2\/instruments\/1192","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/scispx.com\/fr\/wp-json\/wp\/v2\/instruments"}],"about":[{"href":"https:\/\/scispx.com\/fr\/wp-json\/wp\/v2\/types\/instruments"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/scispx.com\/fr\/wp-json\/wp\/v2\/media\/1315"}],"wp:attachment":[{"href":"https:\/\/scispx.com\/fr\/wp-json\/wp\/v2\/media?parent=1192"}],"wp:term":[{"taxonomy":"brands","embeddable":true,"href":"https:\/\/scispx.com\/fr\/wp-json\/wp\/v2\/brands?post=1192"},{"taxonomy":"applications","embeddable":true,"href":"https:\/\/scispx.com\/fr\/wp-json\/wp\/v2\/applications?post=1192"},{"taxonomy":"markets","embeddable":true,"href":"https:\/\/scispx.com\/fr\/wp-json\/wp\/v2\/markets?post=1192"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}