{"id":1179,"date":"2022-12-21T17:09:49","date_gmt":"2022-12-21T16:09:49","guid":{"rendered":"https:\/\/scispx.com\/instruments\/varipol-series\/"},"modified":"2025-11-24T16:24:13","modified_gmt":"2025-11-24T14:24:13","slug":"varipol-polarimetre-modulaire","status":"publish","type":"instruments","link":"https:\/\/scispx.com\/fr\/instruments\/varipol-series\/","title":{"rendered":"VariPol"},"content":{"rendered":"<h2>Polarim\u00e8tre modulaire<\/h2>\n<p>Le VariPol de SCHMIDT + HAENSCH repr\u00e9sente la derni\u00e8re g\u00e9n\u00e9ration de polarim\u00e8tres de pr\u00e9cision, la plus rapide \u00e0 ce jour. Ce polarim\u00e8tre modulaire est sp\u00e9cialement con\u00e7u pour les applications pharmaceutiques, tout en restant adaptable \u00e0 un large \u00e9ventail d\u2019autres utilisations.<\/p>\n<p>Sa pr\u00e9cision de mesure exceptionnelle est associ\u00e9e \u00e0 la modularit\u00e9, \u00e0 la flexibilit\u00e9 et \u00e0 la rapidit\u00e9. La connectivit\u00e9 moderne permet une int\u00e9gration fluide de l\u2019appareil et une surveillance en temps r\u00e9el via le logiciel Aquisys sur votre t\u00e9l\u00e9phone ou votre tablette.<\/p>\n<p>&nbsp;<\/p>\n<h3><strong>Caract\u00e9ristiques du polarim\u00e8tre modulaire<\/strong><\/h3>\n<ul>\n<li>Polarim\u00e8tre de base pour les applications pharmaceutiques, conforme <strong>21 CFR Part 11<\/strong> .<\/li>\n<li>Configuration modulaire<\/li>\n<li>Concept multi-utilisateurs et commande \u00e0 distance via navigateur Internet<\/li>\n<li>Mesures rapides<\/li>\n<li>Syst\u00e8me Peltier pour le contr\u00f4le automatique de la temp\u00e9rature<\/li>\n<li>Calibration facile<\/li>\n<li>Pr\u00e9cision constante sur toute la plage de mesure<\/li>\n<li>Format compact<\/li>\n<li>\u00c9conomie d'\u00e9nergie gr\u00e2ce \u00e0 des LED durables<\/li>\n<li>Compatible ELN\/LIMS<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<h3><strong>Facile \u00e0 utiliser\u00a0<\/strong><\/h3>\n<p>Le design sans tension des tubes d\u2019\u00e9chantillon permet un nettoyage rapide. Les lamelles de couverture peuvent \u00eatre remplac\u00e9es sans provoquer de bir\u00e9fringence. La chambre d\u2019\u00e9chantillon continue ne comporte aucun espace mort, ce qui permet un rin\u00e7age rapide sans laisser de d\u00e9p\u00f4ts.<\/p>\n<p>Les tubes d\u2019\u00e9chantillon rotatifs et les \u00e9talons en quartz permettent de v\u00e9rifier rapidement leur propret\u00e9 et leur bon fonctionnement. L\u2019instrument, les tubes, les plaques en quartz et les accessoires sont tous fabriqu\u00e9s en Allemagne afin de garantir la qualit\u00e9 attendue de SCHMIDT + HAENSCH.<\/p>\n<p>&nbsp;<\/p>\n<h3><strong>Applications\u00a0<\/strong><\/h3>\n<p>Le VariPol dispose d\u2019une chambre d\u2019\u00e9chantillon de 100\u202fmm et est id\u00e9al pour les applications pharmacologiques. Il est conforme \u00e0 la Pharmacop\u00e9e Internationale, \u00e0 la norme 21 CFR Part 11 et \u00e0 l\u2019OIML. Le VariPol est adaptable aux applications m\u00e9dicales, chimiques et sucri\u00e8res. Ses modules de longueur d\u2019onde sont \u00e9changeables pour permettre une utilisation flexible.<\/p>\n<p>&nbsp;<\/p>\n<h3><strong>Le polarim\u00e8tre modulaire en d\u00e9tail\u00a0<\/strong><\/h3>\n<p>Les plus de 150 ans d\u2019expertise en polarim\u00e9trie de SCHMIDT + HAENSCH se refl\u00e8tent dans chaque d\u00e9tail\u202f: du noyau en aluminium renforc\u00e9 \u00e0 l\u2019indicateur int\u00e9gr\u00e9 de qualit\u00e9 des \u00e9chantillons et au contr\u00f4le des \u00e9talons de calibration.<\/p>\n<p>Le nouveau syst\u00e8me Peltier int\u00e9gr\u00e9 ajuste la temp\u00e9rature de 10\u202f\u00b0C en seulement 30\u202fsecondes avec une grande pr\u00e9cision. Une fois stabilis\u00e9e, la mesure ne prend que 6\u202fsecondes. Les composants \u00e9lectroniques optimis\u00e9s et un mode veille moderne r\u00e9duisent la consommation d\u2019\u00e9nergie, permettent des temps de r\u00e9action rapides et favorisent la conservation des ressources.<\/p>\n<p>&nbsp;<\/p>\n<h3><strong>Sp\u00e9cifications\u00a0<\/strong><\/h3>\n<div class=\"elementor-element elementor-element-6836d8d elementor-widget elementor-widget-text-editor\" data-id=\"6836d8d\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n<div class=\"elementor-widget-container\">\n<table style=\"height: 1003px;\" width=\"1089\">\n<tbody>\n<tr>\n<td width=\"197\"><strong>Sp\u00e9cifications<\/strong><\/td>\n<td width=\"323\"><strong>VariPol C<\/strong><\/td>\n<td width=\"360\"><strong>VariPol B<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"197\"><strong>\u00c9chelles de mesure<\/strong><\/td>\n<td colspan=\"2\" width=\"683\">\u00b0 Rotation optique, \u00b0 Rotation sp\u00e9cifique, \u00b0Z \u00c9chelle internationale de sucre, % Concentration (g\/mL, g\/100mL, g\/L), autres \u00e9chelles librement d\u00e9finissables<\/td>\n<\/tr>\n<tr>\n<td width=\"197\"><strong>Plage de mesure<\/strong><\/td>\n<td colspan=\"2\" width=\"683\">\u00b1 89.9\u00b0<\/td>\n<\/tr>\n<tr>\n<td width=\"197\"><strong>Pr\u00e9cision<\/strong><\/td>\n<td width=\"323\">\u00b1 0.01\u00b0 *<\/td>\n<td width=\"360\">\u00b1 0.005\u00b0 *<\/td>\n<\/tr>\n<tr>\n<td width=\"197\"><strong>R\u00e9p\u00e9tabilit\u00e9<\/strong><\/td>\n<td width=\"323\">\u00b1 0.01\u00b0<\/td>\n<td width=\"360\">\u00b1 0.005\u00b0<\/td>\n<\/tr>\n<tr>\n<td width=\"197\"><strong>R\u00e9solution<\/strong><\/td>\n<td width=\"323\">0.005\u00b0<\/td>\n<td width=\"360\">0.001\u00b0<\/td>\n<\/tr>\n<tr>\n<td width=\"197\"><strong>Sensibilit\u00e9<\/strong><\/td>\n<td colspan=\"2\" width=\"683\">Jusqu'\u00e0 OD 3<\/td>\n<\/tr>\n<tr>\n<td width=\"197\"><strong>Longueur d'onde<\/strong><\/td>\n<td colspan=\"2\" width=\"683\">1 ou 2 longueurs d'onde fixes, standard 589 nm, \u00e9galement disponible 365, 405, 436, 546<\/td>\n<\/tr>\n<tr>\n<td width=\"197\"><strong>Temps de mesure<\/strong><\/td>\n<td colspan=\"2\" width=\"683\">6 \u00e0 8 secondes sur toute la plage de mesure<\/td>\n<\/tr>\n<tr>\n<td width=\"197\"><strong>Tubes de mesure<\/strong><\/td>\n<td colspan=\"2\" width=\"683\">Jusqu'\u00e0 100 mm de longueur ; tubes standard, tubes avec entonnoir ou passage ; pi\u00e8ces en contact avec le liquide : verre, acier inoxydable, Hastelloy<\/td>\n<\/tr>\n<tr>\n<td width=\"197\"><strong>Mesure de la temp\u00e9rature<\/strong><\/td>\n<td colspan=\"2\" width=\"683\">Capteur Pt1000 (dispositif) \/ capteur NTC (plaques et tubes de contr\u00f4le \u00e0 quartz)<\/td>\n<\/tr>\n<tr>\n<td width=\"197\"><strong>Plage de temp\u00e9rature de l'\u00e9chantillon<\/strong><\/td>\n<td colspan=\"2\" width=\"683\">10 \u00b0C \u00e0 40 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td width=\"197\"><strong>Pr\u00e9cision de la temp\u00e9rature \/ r\u00e9solution<\/strong><\/td>\n<td colspan=\"2\" width=\"683\">\u00b1 0,1 \u00b0C* \/ 0,01 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td width=\"197\"><strong>R\u00e9gulation de la temp\u00e9rature de la salle d'\u00e9chantillonnage par Peltier<\/strong><\/td>\n<td width=\"323\">18 \u00b0C \u00e0 25 \u00b0C<\/td>\n<td width=\"360\">10 \u00b0C \u00e0 40 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td width=\"197\"><strong>Temps de stabilisation thermique<\/strong><\/td>\n<td colspan=\"2\" width=\"683\">25 \u00b0C \u00e0 20 \u00b0C, \u00b1 0,1 \u00b0C, en 1 minute (valable pour une temp\u00e9rature ambiante = 20 \u00b0C, avec tube)<\/td>\n<\/tr>\n<tr>\n<td width=\"197\"><strong>Source lumineuse<\/strong><\/td>\n<td colspan=\"2\" width=\"683\">LED, filtre d'interf\u00e9rence<\/td>\n<\/tr>\n<tr>\n<td width=\"197\"><strong>Affichage<\/strong><\/td>\n<td colspan=\"2\" width=\"683\">\u00c9cran tactile de 7 pouces**, 800 x 480 pixels<\/td>\n<\/tr>\n<tr>\n<td width=\"197\"><strong>Fonctionnement<\/strong><\/td>\n<td colspan=\"2\" width=\"683\">\u00c9cran tactile**, clavier***, souris***, lecteur de codes-barres***, t\u00e9l\u00e9commande via PC\/tablette\/smartphone***.<\/td>\n<\/tr>\n<tr>\n<td width=\"197\"><strong>Interfaces \/ Communication<\/strong><\/td>\n<td colspan=\"2\" width=\"683\">Ethernet 10\/100\/1000, RS232, USB, WLAN**<\/td>\n<\/tr>\n<tr>\n<td width=\"197\"><strong>Puissance<\/strong><\/td>\n<td colspan=\"2\" width=\"683\">VAC 90-265 ; 50\/60 Hz ; 150 W max<\/td>\n<\/tr>\n<tr>\n<td width=\"197\"><strong>Conformit\u00e9<\/strong><\/td>\n<td colspan=\"2\" width=\"683\">Pharmacop\u00e9e internationale, OIML, 21 CFR part 11, ICUMSA, Australian Standard K157<\/td>\n<\/tr>\n<tr>\n<td width=\"197\"><strong>Dimensions<\/strong><\/td>\n<td colspan=\"2\" width=\"683\">Avec \u00e9cran : 430 x 300 x 270 mm (l x p x h) ; sans \u00e9cran : 430 x 300 x 160 mm (l x p x h)<\/td>\n<\/tr>\n<tr>\n<td width=\"197\"><strong>Points forts<\/strong><\/td>\n<td colspan=\"2\" width=\"683\">Polarim\u00e8tre de base sp\u00e9cialement con\u00e7u pour les applications pharmaceutiques ; Modularit\u00e9 ; Mesure rapide ; Syst\u00e8me \u00e0 effet Peltier pour les applications pharmaceutiques.<br \/>\ncontr\u00f4le automatique de la temp\u00e9rature ; \u00e9talonnage facile ; pr\u00e9cision constante sur toute la plage de mesure, 21 CFR part 11<br \/>\npr\u00eat \u00e0 l'emploi ; LED durables \u00e0 \u00e9conomie d'\u00e9nergie ; ELN ; pr\u00eat \u00e0 l'emploi LIMS<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>* Conditions standard (589 nm, ts=20\u00b0C, tA=23\u00b0C)<br \/>\n** Facultatif<br \/>\n*** Non inclus dans la livraison<\/p>\n<\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Polarim\u00e8tre modulaire pour l'industrie pharmaceutique et plus encore <\/p>","protected":false},"featured_media":3978,"template":"","brands":[266],"applications":[296],"markets":[15,32],"class_list":["post-1179","instruments","type-instruments","status-publish","has-post-thumbnail","hentry","brands-schmidt-_haensch","applications-polarimeters","markets-food-and-beverage","markets-sugar-industry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v25.5 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>VariPol | Modular Polarimeter | SciSPX Analysis simplified<\/title>\n<meta name=\"description\" content=\"Modular polarimeter specifically designed for pharmaceutical applications, in compliance with 21 CFR Part 11.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/scispx.com\/fr\/instruments\/varipol-series\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"VariPol | Modular Polarimeter | SciSPX Analysis simplified\" \/>\n<meta property=\"og:description\" content=\"Modular polarimeter specifically designed for pharmaceutical applications, in compliance with 21 CFR Part 11.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/scispx.com\/fr\/instruments\/varipol-series\/\" \/>\n<meta property=\"og:site_name\" content=\"SciSPX Analysis simplified\" \/>\n<meta property=\"article:modified_time\" content=\"2025-11-24T14:24:13+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/scispx.com\/wp-content\/uploads\/2022\/12\/SH_VariPol_single_withdisplaysoftware_free-1024x766-1.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1024\" \/>\n\t<meta property=\"og:image:height\" content=\"766\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Dur\u00e9e de lecture estim\u00e9e\" \/>\n\t<meta name=\"twitter:data1\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/scispx.com\/fr\/instruments\/varipol-series\/\",\"url\":\"https:\/\/scispx.com\/fr\/instruments\/varipol-series\/\",\"name\":\"VariPol | Modular Polarimeter | SciSPX Analysis simplified\",\"isPartOf\":{\"@id\":\"https:\/\/scispx.com\/fr\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/scispx.com\/fr\/instruments\/varipol-series\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/scispx.com\/fr\/instruments\/varipol-series\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/scispx.com\/wp-content\/uploads\/2022\/12\/SH_VariPol_single_withdisplaysoftware_free-1024x766-1.png\",\"datePublished\":\"2022-12-21T16:09:49+00:00\",\"dateModified\":\"2025-11-24T14:24:13+00:00\",\"description\":\"Modular polarimeter specifically designed for pharmaceutical applications, in compliance with 21 CFR Part 11.\",\"breadcrumb\":{\"@id\":\"https:\/\/scispx.com\/fr\/instruments\/varipol-series\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/scispx.com\/fr\/instruments\/varipol-series\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/scispx.com\/fr\/instruments\/varipol-series\/#primaryimage\",\"url\":\"https:\/\/scispx.com\/wp-content\/uploads\/2022\/12\/SH_VariPol_single_withdisplaysoftware_free-1024x766-1.png\",\"contentUrl\":\"https:\/\/scispx.com\/wp-content\/uploads\/2022\/12\/SH_VariPol_single_withdisplaysoftware_free-1024x766-1.png\",\"width\":1024,\"height\":766,\"caption\":\"modular polarimeter\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/scispx.com\/fr\/instruments\/varipol-series\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/scispx.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Instruments\",\"item\":\"https:\/\/scispx.com\/instruments\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"VariPol\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/scispx.com\/fr\/#website\",\"url\":\"https:\/\/scispx.com\/fr\/\",\"name\":\"SciSPX Analysis simplified\",\"description\":\"SciSPX Analysis simplified\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/scispx.com\/fr\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"VariPol | Polarim\u00e8tre modulaire | SciSPX : l'analyse simplifi\u00e9e","description":"Polarim\u00e8tre modulaire sp\u00e9cialement con\u00e7u pour les applications pharmaceutiques, conforme \u00e0 la norme 21 CFR Part 11.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/scispx.com\/fr\/instruments\/varipol-series\/","og_locale":"fr_FR","og_type":"article","og_title":"VariPol | Modular Polarimeter | SciSPX Analysis simplified","og_description":"Modular polarimeter specifically designed for pharmaceutical applications, in compliance with 21 CFR Part 11.","og_url":"https:\/\/scispx.com\/fr\/instruments\/varipol-series\/","og_site_name":"SciSPX Analysis simplified","article_modified_time":"2025-11-24T14:24:13+00:00","og_image":[{"width":1024,"height":766,"url":"https:\/\/scispx.com\/wp-content\/uploads\/2022\/12\/SH_VariPol_single_withdisplaysoftware_free-1024x766-1.png","type":"image\/png"}],"twitter_card":"summary_large_image","twitter_misc":{"Dur\u00e9e de lecture estim\u00e9e":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/scispx.com\/fr\/instruments\/varipol-series\/","url":"https:\/\/scispx.com\/fr\/instruments\/varipol-series\/","name":"VariPol | Polarim\u00e8tre modulaire | SciSPX : l'analyse simplifi\u00e9e","isPartOf":{"@id":"https:\/\/scispx.com\/fr\/#website"},"primaryImageOfPage":{"@id":"https:\/\/scispx.com\/fr\/instruments\/varipol-series\/#primaryimage"},"image":{"@id":"https:\/\/scispx.com\/fr\/instruments\/varipol-series\/#primaryimage"},"thumbnailUrl":"https:\/\/scispx.com\/wp-content\/uploads\/2022\/12\/SH_VariPol_single_withdisplaysoftware_free-1024x766-1.png","datePublished":"2022-12-21T16:09:49+00:00","dateModified":"2025-11-24T14:24:13+00:00","description":"Polarim\u00e8tre modulaire sp\u00e9cialement con\u00e7u pour les applications pharmaceutiques, conforme \u00e0 la norme 21 CFR Part 11.","breadcrumb":{"@id":"https:\/\/scispx.com\/fr\/instruments\/varipol-series\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/scispx.com\/fr\/instruments\/varipol-series\/"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/scispx.com\/fr\/instruments\/varipol-series\/#primaryimage","url":"https:\/\/scispx.com\/wp-content\/uploads\/2022\/12\/SH_VariPol_single_withdisplaysoftware_free-1024x766-1.png","contentUrl":"https:\/\/scispx.com\/wp-content\/uploads\/2022\/12\/SH_VariPol_single_withdisplaysoftware_free-1024x766-1.png","width":1024,"height":766,"caption":"modular polarimeter"},{"@type":"BreadcrumbList","@id":"https:\/\/scispx.com\/fr\/instruments\/varipol-series\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/scispx.com\/"},{"@type":"ListItem","position":2,"name":"Instruments","item":"https:\/\/scispx.com\/instruments\/"},{"@type":"ListItem","position":3,"name":"VariPol"}]},{"@type":"WebSite","@id":"https:\/\/scispx.com\/fr\/#website","url":"https:\/\/scispx.com\/fr\/","name":"SciSPX Analyse simplifi\u00e9e","description":"SciSPX Analyse simplifi\u00e9e","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/scispx.com\/fr\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"}]}},"_links":{"self":[{"href":"https:\/\/scispx.com\/fr\/wp-json\/wp\/v2\/instruments\/1179","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/scispx.com\/fr\/wp-json\/wp\/v2\/instruments"}],"about":[{"href":"https:\/\/scispx.com\/fr\/wp-json\/wp\/v2\/types\/instruments"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/scispx.com\/fr\/wp-json\/wp\/v2\/media\/3978"}],"wp:attachment":[{"href":"https:\/\/scispx.com\/fr\/wp-json\/wp\/v2\/media?parent=1179"}],"wp:term":[{"taxonomy":"brands","embeddable":true,"href":"https:\/\/scispx.com\/fr\/wp-json\/wp\/v2\/brands?post=1179"},{"taxonomy":"applications","embeddable":true,"href":"https:\/\/scispx.com\/fr\/wp-json\/wp\/v2\/applications?post=1179"},{"taxonomy":"markets","embeddable":true,"href":"https:\/\/scispx.com\/fr\/wp-json\/wp\/v2\/markets?post=1179"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}